The Riello FD01 Photoelectric Cell is a critical component designed for use in Riello oil burners. Its primary function is to detect the presence of a flame, ensuring safe and efficient operation of the heating system. This cell acts as a sensor, signaling the control unit about the combustion status. It is an essential spare part for maintaining the functionality of compatible Riello burner models.

Riello FD01 Photoelectric Cell with wires and connector

Foto 1.1: Riello FD01 Photoelectric Cell. This image displays the main component with its attached wiring and connector, ready for installation.

2. Ndakọrịta

The Riello FD01 Photoelectric Cell is compatible with a range of Riello burner models. Please verify your burner model number against the list below to ensure proper fit and function. This component is specifically designed to work in conjunction with the MO550 BWG or MO550 MWG control units.

Compatible Burner Models:

Mara: Compatibility is only ensured when used in conjunction with the MO550 BWG or MO550 MWG control unit.

3. Ntọala na nwụnye

Installation of the Riello FD01 Photoelectric Cell involves working with electrical and fuel systems. For safety and proper function, installation and replacement procedures must be performed by a qualified and certified technician. Incorrect installation can lead to equipment damage, fire, or personal injury.

3.1 Replacement Procedure (General Guidelines)

  1. Nchekwa Mbụ: Ensure the burner and heating system are completely powered off and disconnected from the main electricity supply. Close any fuel supply valves.
  2. Nweta: Carefully open the burner housing to access the existing photoelectric cell.
  3. Ịkwụsị: Disconnect the wiring from the old photoelectric cell and carefully remove it from its mounting. Note the orientation and connection points.
  4. Nwụnye: Insert the new Riello FD01 Photoelectric Cell into the designated slot, ensuring it is securely seated. Connect the wiring according to the burner's electrical diagram.
  5. Reassembly & Testing: Close the burner housing. Restore power and fuel supply. Perform a functional test of the burner to ensure the new cell is operating correctly and detecting the flame.
Riello FD01 Photoelectric Cell from a different angle, showing the sensor end

Foto 3.1: Riello FD01 Photoelectric Cell, side view. This image provides a clearer view of the sensor's body and the integrated mounting features.

3.2 Specific Replacement Note for 3007492

If the existing photo resistance with part number 3007492 is found to be defective, it is recommended that the entire control unit be replaced. In such cases, the conversion kit 20146982 (which includes the MO550 BWG control unit and the FD01 photo resistance) is advised for a complete and compatible solution.

4. Ntuziaka ọrụ

The Riello FD01 Photoelectric Cell operates automatically as part of the burner's control system. It continuously monitors the flame during burner operation. There are no direct user operating controls for this component. Its function is entirely passive, providing feedback to the burner's control unit.

5. Nlekọta

The Riello FD01 Photoelectric Cell generally requires minimal maintenance. However, as part of routine burner servicing, a qualified technician should inspect the cell for any signs of damage or excessive soot accumulation on its sensing surface. A clean sensing surface is crucial for accurate flame detection.

Riello FD01 Photoelectric Cell with wires and connector, showing the connector in detail

Foto 5.1: Riello FD01 Photoelectric Cell, connector view. This image highlights the electrical connector, which is crucial for proper wiring during installation.

6. Nchọpụta nsogbu

If your oil burner is experiencing issues related to flame detection or failure to ignite, the photoelectric cell may be a contributing factor. Always consult a qualified technician for diagnosis and repair.

6.1 Okwu nkịtị na Ngwọta

Ihe dị mkpa: Do not attempt to repair the photoelectric cell or control unit yourself. Contact a professional heating technician for all diagnostic and repair work.

7. Nkọwapụta

ỤdịRiello
NlereanyaFD01
Part Number (ASIN)B07H32C3P6
ỌrụFlame detection for oil burners
Ndebanye aha ndakọrịtaRequires MO550 BWG or MO550 MWG control unit for full compatibility with listed burner models.
Onye nrụpụtaRiello

For detailed technical drawings or specific electrical parameters, please refer to the official Riello documentation for your specific burner model or contact Riello customer support.

8. Akwụkwọ ikike na nkwado

Information regarding the warranty for the Riello FD01 Photoelectric Cell is not provided within this instruction manual. For warranty details, technical support, or to locate authorized service centers, please contact your original point of purchase or visit the official Riello website. Always provide your product model and serial number when seeking support.

Akwụkwọ ndị emetụtara - FD01

Tupuview Riello RG2D Light Oil Burner Installation and Maintenance Manual
Comprehensive guide for the Riello RG2D light oil burner, covering installation, operation, maintenance, and troubleshooting. Includes technical specifications, diagrams, and safety instructions.
Tupuview Ndepụta akụkụ na eserese nke Riello Gulliver RG2F
Ndepụta akụkụ mapụtara zuru ezu na eserese akụrụngwa maka ọkụ mmanụ ọkụ Riello Gulliver RG2F (Model 377T1, Code 3737770), gụnyere nọmba akụkụ na nkọwa bekee.
Tupuview Riello 40 Series Residential Oil Burners F3 & F5 Akwụkwọ ntuziaka nwụnye
Akwụkwọ ntuziaka a na-enye ntuziaka nrụnye zuru ezu maka Riello 40 Series Residential oil Burners, ụdị F3 na F5. Ọ na-ekpuchi njirimara akụrụngwa, ntọlite ​​​​, ịrị elu, njikọ eletriki, ntinye nozzle, na usoro mmezi. Ezubere akwụkwọ ntuziaka maka ngwa nrụgharị ma gụnye data teknụzụ, nkọwapụta na ndepụta akụkụ mapụtara.
Tupuview Ị nweta aha, uporabo na vzdrževanje gorilnika RIELLO Gulliver RG1NR na plinsko olje
Ta dokument vsebuje podrobna navodila za namestitev, uporabo, vzdrževanje na odpravljanje napak enostopenjskega gorilnika RIELLO Gulliver RG1NR na plinsko olje, vključno s tehničnimi podatmi predsivarnost odpravljanje na postedivalnost post. tazav.
Tupuview Riello 40 BF Single Stage Operation Oil Burner Installation and Operating Manual
Comprehensive installation and operating manual for the Riello 40 BF single-stage oil burner, covering technical specifications, installation procedures, wiring diagrams, troubleshooting, and spare parts.
Tupuview Riello 40 Series F3 & F5 Residential Oil Burner Installation Manual
Comprehensive installation manual for Riello 40 Series residential oil burners, models F3 and F5. Covers technical data, component identification, setup, mounting, electrical connections, oil line configuration, pump purge, adjustments, and spare parts.