VOLTCRAFT IR 500-12S

VOLTCRAFT IR 500-12S Infrared Thermometer User Manual

Model: IR 500-12S | Brand: VOLTCRAFT

1. Okwu mmalite

The VOLTCRAFT IR 500-12S is a robust and practical infrared thermometer designed for non-contact temperature measurement. It features a pistol grip for comfortable handling and allows for safe and precise surface temperature readings of objects ranging from -50 °C to +500 °C. This device is suitable for various applications in home, hobby, and professional environments, including measuring temperatures of rotating parts, live conductors, hard-to-reach areas, or dangerously hot objects.

2. Ntuziaka nchekwa

Biko gụọ ma ghọta ntuziaka nchekwa niile tupu ị rụọ ọrụ ngwaọrụ ahụ. Ọ bụrụ na ị gbasoghị ntuziaka ndị a, ọ nwere ike ibute mmerụ ahụ ma ọ bụ mmebi na ngwaọrụ ahụ.

  • Nchekwa laser: Do not look directly into the laser beam or point it at people or animals. The laser is used for aiming only and is not part of the temperature measurement process.
  • Oke okpomọkụ: Do not expose the device to extreme temperatures outside its operating range (-50 °C to +500 °C) or to sudden, drastic temperature changes.
  • Nchekwa Eletriki: This device measures surface temperature and is not designed to measure internal temperatures of living beings or to detect electrical current directly. Exercise caution when measuring hot or electrically live surfaces.
  • Nhicha: Jiri nwayọọ, damp akwa maka nhicha . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
  • Ijikwa batrị: Ensure correct battery polarity. Remove batteries if the device will not be used for an extended period. Dispose of used batteries responsibly.
  • Nlekọta: Anwala imepe ma ọ bụ gbanwee ngwaọrụ ahụ. Nye ndị ọrụ ruru eru ọrụ niile.

3. Ngwaahịa gafereview

Familiarize yourself with the components of your VOLTCRAFT IR 500-12S infrared thermometer.

VOLTCRAFT IR 500-12S Infrared Thermometer Front View

Foto 3.1: N'ihu view of the VOLTCRAFT IR 500-12S Infrared Thermometer, showing the display, measurement trigger, and control buttons.

VOLTCRAFT IR 500-12S Infrared Thermometer Side View with Optical Ratio

Foto 3.2: Akụkụ view of the thermometer, illustrating the 12:1 distance-to-spot ratio for accurate measurements.

VOLTCRAFT IR 500-12S Infrared Thermometer Angled View

Foto 3.3: N'akuku view of the device, highlighting the VOLTCRAFT branding and model number.

3.1. Isi ihe

  • Measurement Trigger: Located on the handle, used to initiate temperature readings.
  • Ngosipụta LCD: Digital display showing temperature readings, units, and other indicators.
  • Bọtịnụ ihe ntụle laser: Activates/deactivates the aiming laser.
  • bọtịnụ Celsius C/F: Na-agbanwe n'etiti nkeji okpomọkụ Celsius na Fahrenheit.
  • Bọtịnụ MAX/MIN: Displays the maximum or minimum temperature recorded during a measurement session.
  • Sensọ infrared: Located at the front of the device, responsible for detecting infrared radiation.
  • Akụkụ batrị: Located in the handle for a 9V battery.

4. Nhazi

4.1. Ntinye batrị

  1. Chọta ebe mkpuchi batrị na aka nke temometa.
  2. Mepee mkpuchi nke batrị batrị.
  3. Insert one 9V battery, ensuring correct polarity (+ and - terminals).
  4. Mechie mkpuchi nke batrị batrị nke ọma.

The device is now ready for use. If the battery indicator appears on the display, replace the battery.

5. Ntuziaka ọrụ

5.1. Iwere nha

  1. Point the infrared sensor towards the target object.
  2. Press and hold the measurement trigger. The laser pointer (if activated) will indicate the center of the measurement area.
  3. The temperature reading will appear on the LCD display instantly.
  4. Release the trigger to hold the last measured temperature on the display. The "HOLD" indicator will appear.

Note on Distance-to-Spot Ratio: The VOLTCRAFT IR 500-12S has an optical resolution of 12:1. This means that at a distance of 12 units, the measurement spot diameter is 1 unit. For accurate readings, ensure the target object is larger than the measurement spot size.

5.2. Nhọrọ nkeji (°C/°F)

Pịa ° C/° F bọtịnụ iji gbanwee n'etiti nkeji okpomọkụ Celsius na Fahrenheit.

5.3. MAX/MIN Function

While holding the measurement trigger, press the MAX/MIN button to cycle through the maximum and minimum temperatures recorded during the current measurement session. Release the trigger to exit this mode.

5.4. Laser Pointer

Press the laser button (often marked with a laser icon) to activate or deactivate the laser pointer. The laser assists in aiming the thermometer at the desired measurement spot.

5.5. Emissivity

The VOLTCRAFT IR 500-12S has a fixed emissivity of 0.95. This value is suitable for most organic materials, painted surfaces, and many non-metals. For highly reflective surfaces (e.g., polished metals), readings may be less accurate. No adjustment is required or possible on this model.

6. Nlekọta

6.1. Nhicha

  • Hichapụ ngwaọrụ ahụ casing with a soft, slightly damp akwa .
  • Ejila ihe nhicha, ihe mgbaze, ma ọ bụ mikpuo ngwaọrụ ahụ n'ime mmiri.
  • Clean the infrared lens gently with a soft cloth or cotton swab, using only water or lens cleaning solution. Avoid scratching the lens.

6.2. Nchekwa

  • Chekwaa temometa n'ebe dị jụụ, kpọrọ nkụ, pụọ na ìhè anyanwụ kpọmkwem na oke okpomọkụ.
  • Wepụ batrị ahụ ma ọ bụrụ na a gaghị eji ngwaọrụ ahụ ruo ogologo oge iji gbochie mmiri ịpụ apụ.

7. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Ngwaọrụ anaghị agbanwu.Batrị dị ala ma ọ bụ nke nwụrụ anwụ; ntinye batrị na-ezighi ezi.Dochie batrị 9V ahụ; hụ na polarity ziri ezi.
Ọgụgụ na-ezighi ezi.Measurement distance too far; target object too small; highly reflective surface; dirty lens.Move closer to the target; ensure target is larger than spot size; consider emissivity limitations for reflective surfaces; clean the lens.
Ozi "Err" na ngosi.Temperature outside measurement range; sensor error.Ensure target temperature is within -50 °C to +500 °C; if error persists, contact support.
Laser not working.Laser deactivated; low battery.Press the laser button to activate; replace battery if low.

8. Nkọwapụta

OkeUru
Oke okpomọkụ-50C ruo +500C (-58°F ruo +932°F)
Optical Resolution (D:S)12:1
Oge nzaghachi500 ms
MmetụtaIdozi na 0.95
Ụdị LaserSingle laser for aiming
Ụdị ngosiDijitalụ LCD
Ịnye ọkụBatrị 1 x 9V (anaghị etinye ya)
Akụkụ (L x W x H)3.9 x 7.3 x 14 cm (1.5 x 2.9 x 5.5 inch)
Ibu130 grams (approx. 4.6 oz)
Atụmatụ pụrụ icheNon-contact measurement, MAX/MIN function, °C/°F selection
Nọmba ihe nlereanya nke edemede1599562

9. Akwụkwọ ikike na nkwado

9.1. Akwụkwọ ikike Ozi

This VOLTCRAFT product is covered by a standard warranty for spare parts for a period of 1 year from the date of purchase. Please retain your proof of purchase for warranty claims. The warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by misuse, accident, unauthorized modification, or improper maintenance.

9.2. Nkwado ndị ahịa

For technical assistance, troubleshooting, or warranty inquiries, please contact VOLTCRAFT customer support. Refer to the contact information provided with your product packaging or visit the official VOLTCRAFT websaịtị maka nkọwa nkwado kachasị ọhụrụ.

Akụrụngwa dị n'ịntanetị: For additional information and FAQs, please visit the VOLTCRAFT official websaịtị.

Akwụkwọ ndị emetụtara - IR 500-12S

Tupuview Voltcraft IR 650-12D & IR 800-20D Infrared Thermometer User Manual
Comprehensive operating instructions and technical specifications for the Voltcraft IR 650-12D and IR 800-20D infrared thermometers, covering features, usage, safety, and maintenance.
Tupuview VOLTCRAFT K101/K102 Digital Thermometer User Manual
User manual for the VOLTCRAFT K101 and K102 digital thermometers, detailing features, operation, safety guidelines, and technical specifications for accurate temperature measurement using K-type thermocouples.
Tupuview Manuale d'uso Termometro Palmare Digitale VOLTCRAFT K101/K102
Istruzioni dettagliate per l'uso, la sicurezza, il funzionamento, la manutenzione e le specifiche tecniche per i termometri digitali VOLTCRAFT K101 e K102, progettati per misurazioni precise della temperatura con termocoppie di tipo K.
Tupuview Voltcraft Thermal Camera User Manual
Comprehensive user manual for Voltcraft thermal cameras, covering operation, features, technical specifications, and troubleshooting. Includes instructions on setup, image capture, data management, and maintenance.
Tupuview Voltcraft VC371 40A AC/DC Mini Clamp Ntuziaka Ọrụ nke Mita
Akwụkwọ a na-enye ntuziaka ọrụ zuru oke na ntuziaka nchekwa maka VOLTCRAFT VC371 40A AC/DC Mini Clamp Mita. Ọ na-akọwapụta atụmatụ ngwaahịa, usoro nha maka ọkụ eletrik AC/DC na voltage, resistance, capacitance, and includes troubleshooting and technical specifications.
Tupuview VOLTCRAFT MT-52 5-in-1 Digital Multimeter User Manual
This document provides comprehensive operating instructions, safety guidelines, and technical specifications for the VOLTCRAFT MT-52 5-in-1 Digital Multimeter. Learn how to measure voltage, current, resistance, temperature, humidity, light, and sound levels.