1. Ngwaahịa gafereview
The Lithonia Lighting QTE LED P2 40K 120 THK DDB M6 LED Flood Light features a traditional and robust design with energy-efficient LEDs. It is engineered to replace up to 500W quartz halogen fixtures, making it an ideal solution for landscape, signage, and accent lighting in both commercial and residential outdoor applications.
Akụkụ ndị bụ isi:
- Ike ike: Provides 4,000 lumens with a 4000K cool white temperature, consuming only 40 watts.
- Ogologo ndụ: Designed for up to 50,000 hours of light, equivalent to 17 years when used 8 hours a day.
- Ihe owuwu na-adịgide adịgide: Made from high-quality materials for extended reliability.
- High Industry Ratings: UL listed for safety in the United States and Canada, and DLC certified.
- Wet Location Suitable: Engineered for outdoor use in wet conditions.
2. Ozi nchekwa dị mkpa
Ịdọ aka ná ntị: This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Failure to do so may result in electric shock, fire, or other hazards.
- Kwupu ike mgbe niile na ihe nbibi sekit tupu echichi ma ọ bụ ọrụ.
- Ensure all electrical connections are secure and comply with local and national electrical codes.
- Do not handle live wires.
- Kpọtụrụ onye ọrụ eletrik tozuru oke ma ọ bụrụ na ị maghị akụkụ ọ bụla nke usoro nrụnye.
3. Gịnị gụnyere
Chọpụta na akụrụngwa niile dị tupu ịmalite nrụnye:
- LED Flood Light Fixture (1)
- Efere Efere (1)
- Akụ waya (3)
- Screws for mounting (various sizes)
- Ntuziaka nwụnye

Figure 1: Main product view of the Lithonia Lighting QTE LED Flood Light.
4. Ntuziaka nwụnye
This flood light is designed for surface mount installation. Ensure the mounting surface is sturdy and capable of supporting the fixture's weight.
4.1. Na-akwadebe maka nwụnye
- Gbanyụọ Ike: Locate the circuit breaker controlling the installation area and turn off the power. Verify power is off using a voltagọ bụ onye nyocha.
- Remove Existing Fixture (if applicable): Carefully remove any old lighting fixture, ensuring all wires are disconnected and secured.
- Kwadebe elu elu: Ensure the mounting surface is clean, dry, and free of debris.
4.2. Ịkwanye ihe ndozi
- Tinye efere nkwụnye: Secure the provided mounting plate to the junction box or desired surface using appropriate screws. Ensure it is firmly attached.
- Njikọ waya: Connect the flood light's wires to your electrical system's wires. Follow standard electrical color codes:
- waya ojii (ọkụ) to the black (hot) wire from the power supply.
- waya ọcha (anọpụ iche) to the white (neutral) wire from the power supply.
- Green wire (Ground) to the green or bare copper (ground) wire from the power supply.
- Secure Fixture to Mounting Plate: Align the flood light's base with the mounting plate and secure it using the provided screws. Ensure a tight seal to prevent moisture intrusion.
- Gbanwee akụkụ: The fixture features an adjustable knuckle mount. Loosen the Phillips screw on the side of the knuckle, adjust the light to the desired projection angle, and then tighten the screw firmly to secure its position.

Foto 2: N'ihu view of the LED Flood Light, showing the LED array.

Ọgụgụ 3: Azụ view of the LED Flood Light, highlighting the heat dissipation fins and photocell sensor.

Foto 4: Akụkụ view of the LED Flood Light, illustrating the adjustable knuckle mount for directing light.
5. Ntuziaka ọrụ
5.1. Photocell Functionality
This flood light is equipped with a built-in photocell sensor, enabling automatic dusk-to-dawn operation. The sensor detects ambient light levels and will turn the fixture on when it gets dark and off when it gets light.
- Ensure the photocell sensor (located on the back of the fixture) is not obstructed by any objects, as this may interfere with its proper function.
- No manual adjustment is typically required for the photocell once installed correctly.
6. Nlekọta na nlekọta
To ensure optimal performance and longevity of your LED Flood Light, follow these maintenance guidelines:
- Nhicha: Periodically clean the lens and exterior of the fixture with a soft, damp cloth. Do not use abrasive cleaners or solvents, as they may damage the finish or lens.
- Nyocha: Regularly inspect the fixture for any signs of damage, loose connections, or wear. Address any issues promptly.
- Enweghị akụkụ ndị ọrụ-ọrụ: The LED components are integrated and not user-replaceable. Do not attempt to open the fixture.
7. Nchọpụta nsogbu
If your LED Flood Light is not functioning as expected, refer to the following common issues and solutions:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Ìhè anaghị agbanwuo. | Enweghị ikike na ngwa. | Lelee ihe na-agbaji sekit na njikọ eletriki. |
| Ìhè na-anọ n'ehihie. | Photocell sensor is obstructed or faulty. | Ensure photocell is clear of obstructions. If problem persists, contact customer support. |
| Ìhè flickers. | Loose wiring connection or power fluctuation. | Check all wiring connections. Consult an electrician if necessary. |
8. Nka na ụzụ nkọwa
| Nkọwapụta | Uru |
|---|---|
| Nọmba nlereanya | QTE LED P2 40K 120 THK DDB M6 |
| Ụdị | Lithonia Lighting |
| Wattage | 40 watt |
| Icha ọkụ | 4000 lumen |
| Okpomọkụ agba | 4000 Kelvin (dị ọcha) |
| Ihe onwunwe | Aluminom |
| Ụdị mmecha | Painted (Dark Bronze) |
| Voltage | 120 volts |
| Ojiji ime ime/n'èzí | N'èzí |
| Ọkwa Nguzogide mmiri | Mmiri na-eguzogide |
| Akụkụ ngwaahịa | 12 x 12 x 7 sentimita asatọ |
| Ibu Ibu | 2.49 pound |
| Asambodo | UL Listed (US & Canada), DLC Certified |
9. Akwụkwọ ikike na nkwado ndị ahịa
This Lithonia Lighting QTE LED Flood Light is backed by a Akwụkwọ ikike dị afọ 5. For warranty claims, technical assistance, or any product-related inquiries, please contact Lithonia Lighting customer service.
Refer to the product packaging or the official Lithonia Lighting websaịtị maka ozi kọntaktị kachasị ọhụrụ na usoro nkwa zuru ezu.