1. Ozi nchekwa dị mkpa
Please read this manual thoroughly before installing, operating, or performing maintenance on your Cata GL 45 X range hood. Keep this manual for future reference. Failure to follow these instructions could result in electric shock, fire, or injury.
- Ensure the electrical installation complies with local regulations and is performed by a qualified electrician.
- Kwụpụ ngwa ngwa na ọkụ ọkụ mgbe niile tupu ihicha ma ọ bụ rụọ ọrụ ọ bụla.
- Ezubere ngwa a maka iji ndị mmadụ (gụnyere ụmụaka) nwere ike anụ ahụ, mmetụta uche ma ọ bụ nke uche, ma ọ bụ enweghị ahụmịhe na ihe ọmụma, ma ọ bụrụ na enyereghị ha nlekọta ma ọ bụ ntụziaka gbasara iji ngwa ahụ site n'aka onye na-ahụ maka nchekwa ha.
- Ejila flambé n'okpuru mkpuchi nso.
- Ensure adequate ventilation in the room when the range hood is used simultaneously with appliances burning gas or other fuels.
- Agaghị agbanye ikuku n'ime flue nke a na-eji eme ka uzuzu si na ngwa na-ere gas ma ọ bụ mmanụ ndị ọzọ.
2. Ntọala na nwụnye
2.1 Nwepu
Carefully remove the range hood from its packaging. Inspect the appliance for any damage. Keep packaging materials away from children.
2.2 Ebe na ịrị elu
The Cata GL 45 X is an integrated kitchen hood designed for under-cabinet mounting. Ensure sufficient clearance above your cooking surface as per local safety regulations. The hood features an easy installation system.

Image: Cata GL 45 X Range Hood installed under a kitchen cabinet, showing its integrated design.
2.3 Akụkụ
Refer to the diagram below for precise dimensions to ensure proper fit and installation.

Image: Technical drawing illustrating the dimensions of the Cata GL 45 X Range Hood.
2.4 Njikọ eletrik
The appliance operates on 220 Volts. Ensure the power supply is compatible. It is recommended that a qualified technician performs the electrical connection.
2.5 Ventilation Options
The hood supports both ducted and recirculation (ductless) ventilation. The discharge diameter is 150/125 mm for ducted installations. For recirculation, ensure active carbon filters are installed.
3. Ntuziaka ọrụ
The Cata GL 45 X features a touch control panel for easy operation.

Foto: nso nso view of the touch control panel with power level indicators and light controls.
Ọkwa ike 3.1
The hood offers 4 extraction speeds: 3 standard levels and 1 Turbo level. Adjust the power according to the intensity of cooking fumes and odors.
- Ọkwa 1-3: For light to moderate cooking.
- Turbo Level: For intense cooking or strong odors, providing maximum extraction capacity of 820 m³/h.
3.2 ọkụ ọkụ LED
The integrated high-efficiency LED lights are adjustable in intensity, providing illumination for your cooking area.
3.3 Automatic Shut-off Timer
Utilize the automatic shut-off timer function to program the hood to continue operating for a set period after cooking, ensuring complete removal of residual fumes and odors.
3.4 Usage Recommendations
- Turn on the hood approximately 5 minutes before you begin cooking to establish an airflow.
- Use cooking zones closest to the wall to optimize fume capture.
- Avoid drafts during cooking, as this can interfere with the hood's effectiveness.
- Cover boiling pots and pans to reduce steam production.
- After cooking, keep the hood running for at least 5 to 15 minutes, depending on the intensity of fumes and odors generated.
4. Nlekọta
4.1 Cleaning Metal Filters
The metal grease filters are dishwasher-safe and should be cleaned periodically to maintain optimal performance. The hood features a filter cleaning indicator to remind you when cleaning is due.

Foto: View of the metal grease filters, designed for easy removal and cleaning.
4.2 Replacing Charcoal Filters (Recirculation Mode)
If your hood is operating in recirculation mode, the active charcoal filters (included) must be replaced regularly, typically every 3-6 months depending on usage. Refer to the specific instructions provided with the charcoal filters for replacement procedures.
4.3 Nhicha mputa
Clean the stainless steel exterior with a soft cloth and a mild, non-abrasive cleaner. Avoid using harsh chemicals or abrasive materials that could damage the finish.
5. Nchọpụta nsogbu
If you encounter issues with your Cata GL 45 X range hood, consult the following table before contacting customer service.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Ike mmiri dị ala | Ihe nzacha griiz mechiri emechi Improper ducting Obstruction in air outlet | Clean or replace grease filters Check ducting for bends or blockages Wepụ ihe mgbochi ọ bụla |
| Oke mkpọtụ | Ngwa ndị rụrụ arụ Ntinye na-ezighi ezi Ducting issues | Lelee ma mechie akụkụ ọ bụla rụrụ arụ Ensure secure mounting Inspect ducting for proper size and smooth path |
| Ọkụ anaghị arụ ọrụ | Okwu ọkọnọ ike Modul LED ezighi ezi | Lelee njikọ ọkụ na ihe mgbaji sekit Contact service for LED replacement |
| Ogwe njikwa anaghị anabata | Okwu ọkọnọ ike Panel dirty or wet | Lelee njikọ ike Clean and dry the control panel thoroughly |
If the problem persists after attempting these solutions, please contact CATA customer support.
6. Nkọwapụta
Key technical specifications for the Cata GL 45 X Range Hood:
| Njirimara | Nkọwapụta |
|---|---|
| Nọmba nlereanya | GL-45 X |
| Voltage | 220 volts |
| Ike | 280 Watt |
| Ọnụọgụ nke Ọsọ ọsọ | 4 (3 + 1 Turbo) |
| Ike ikuku | 820 m³/h (maximum) |
| Ọkwa ụda | 50 Desibels (opekempe) |
| Akụkụ (L x W x H) | 27.7 x 49.2 x 28 cm |
| Ibu Ibu | 15 kilogram |
| Klas arụmọrụ ike | A |
| Oriri ike kwa afọ | 58 kWh / afọ |
| Ụdị isi iyi ọkụ | Ikanam |
| Ụdị nzacha | Mesh (Dishwasher-safe metal filters) |
| Ụdị ikuku ikuku | Ductless/Recirculation |
| Ihe onwunwe | Igwe anaghị agba nchara |
| Ụdị njikwa | Metụ aka |
Energy Label Information:

Image: EU Energy Label for the Cata GL 45 X Range Hood, indicating Class A energy efficiency and other performance metrics.
7. Akwụkwọ ikike na nkwado
CATA products are manufactured using high-quality components and advanced techniques. For warranty information, please refer to the documentation provided at the time of purchase or visit the official CATA website. For technical support, spare parts, or service inquiries, please contact your local CATA service center or the retailer from whom you purchased the product.