Knightsbridge CU4200

Knightsbridge CU4200 Curved Edge 10A 6 Gang 2 Way Switch User Manual

Ụdị: CU4200

1. Okwu mmalite

Thank you for choosing the Knightsbridge CU4200 Curved Edge 10A 6 Gang 2 Way Switch. This manual provides essential information for the safe installation, operation, and maintenance of your new electrical switch. Please read these instructions carefully before installation and retain them for future reference.

2. Ozi nchekwa

Ịdọ aka ná ntị: Electricity can be dangerous. Installation must be carried out by a qualified electrician or competent person in accordance with the latest IEE Wiring Regulations (BS7671) and local building regulations.

  • Always isolate the mains power supply before commencing any electrical work.
  • Ensure the circuit is dead using a suitable voltage tester tupu emetụ wires ọ bụla aka.
  • Emebere ngwaahịa a maka naanị ime ụlọ.
  • Do not exceed the rated current of 10 Amperes.
  • Ensure all connections are secure and correctly wired.
  • Ọ bụrụ na ị na-enwe obi abụọ, kpọtụrụ onye ọrụ ọkụ eletrik tozuru etozu.

3. Ihe ngwugwu

Biko lelee na akụrụngwa niile dị na enweghị mmebi:

  • 1 x Knightsbridge CU4200 6 Gang 2 Way Switch Unit
  • 2 x Idozi skru

4. Ngwaahịa gafereview

The Knightsbridge CU4200 is a 6-gang, 2-way light switch designed for controlling up to six separate lighting circuits from one or two locations. It features a curved edge design and a white finish.

N'ihu view of the Knightsbridge CU4200 6 Gang 2 Way Switch

Foto 1: N'ihu view of the Knightsbridge CU4200 6 Gang 2 Way Switch. This image shows the white faceplate with six individual rocker switches arranged in two rows of three.

N'azụ view of the Knightsbridge CU4200 6 Gang 2 Way Switch showing wiring terminals

Foto 2: N'azụ view of the switch unit, displaying the terminal blocks for electrical connections. Each switch module has terminals labeled 'COM', 'L1', and 'L2'. The text 'MADE IN CHINA' is visible.

Close-up of wiring terminals on the Knightsbridge CU4200 switch

Foto 3: Detailed close-up of the wiring terminals. Each switch module clearly shows screw terminals for 'COM' (Common), 'L1' (Switched Live 1), and 'L2' (Switched Live 2), indicating its 2-way functionality. The rating '10AX 250V' is also visible.

Technical drawing with dimensions of the Knightsbridge CU4200 switch

Foto 4: Technical drawing illustrating the dimensions of the switch. The drawing indicates a width of 146mm, a height of 86mm, and a depth of 21mm to the back base.

5. Nwụnye

Tupu ịmalite: Ensure the mains power supply to the circuit you are working on is switched off at the consumer unit/fuse box and secured against accidental re-connection. Use a suitable voltage tester iji gosi na sekit anwụọla.

Wiring Instructions (2-Way Switching)

The CU4200 is a 2-way switch, meaning each gang can control a light from two different locations. Refer to Onyonyo 2 na Onyonyo 3 for terminal identification.

  1. Kwadebe wires: Carefully strip the insulation from the ends of the circuit wires (Live, Neutral, Earth, and Switched Lives/Strappers) to expose approximately 10-12mm of copper conductor.
  2. Njikọ ụwa: Connect the bare copper or green/yellow insulated Earth wire from the circuit to the Earth terminal on the back box (if applicable) and ensure continuity. The switch itself does not have an Earth terminal as it is a Class II product (double insulated), but the metal back box must be earthed.
  3. Common (COM) Connection: For each switch gang, connect the permanent live wire (usually brown or red) to the 'COM' terminal. If multiple gangs share a common live feed, a short link wire may be used between the 'COM' terminals of adjacent switches.
  4. Switched Live (L1 & L2) Connections:
    • For 2-Way Switching: Connect the two 'strapping' wires (often brown with red/yellow sleeves or grey/black) between the 'L1' and 'L2' terminals of this switch and the corresponding 'L1' and 'L2' terminals of the other 2-way switch controlling the same light.
    • The switched live wire going to the light fitting should be connected to either 'L1' or 'L2' on one of the 2-way switches (typically the one where the light feed originates).
  5. Njikọ echekwara Ensure all wires are fully inserted into their respective terminals and the terminal screws are tightened firmly. Tug gently on each wire to confirm it is secure.
  6. Ịkwanye: Carefully position the switch unit into the wall box, ensuring no wires are trapped or pinched. Secure the switch to the wall box using the provided fixing screws.
  7. Ihuenyo: Attach the faceplate to the switch unit.
  8. Weghachi ike: Once installation is complete and all connections are checked, restore the mains power supply at the consumer unit/fuse box.

6. Ntuziaka ọrụ

To operate the switch, simply press the top or bottom of each rocker switch to toggle the connected light circuit on or off. In a 2-way setup, the light can be switched from either the CU4200 or the other connected 2-way switch.

7. Nlekọta

The Knightsbridge CU4200 switch requires minimal maintenance. To clean the surface, wipe with a soft, dry cloth. Do not use abrasive cleaners, solvents, or polishes as these may damage the finish. Ensure power is off before cleaning.

8. Nchọpụta nsogbu

If the switch is not functioning correctly, consider the following:

  • No Power to Light: Check the circuit breaker or fuse at the consumer unit. Ensure all wiring connections are secure and correct (refer to Section 5).
  • Ọrụ na-adịte aka: Loose wiring connections are a common cause. Isolate power and re-check all terminal screws.
  • Mgbanwe ahụ Na-adị Ka Ọ Dịghị Mma: Ensure the fixing screws securing the switch to the wall box are tightened.

Ọ bụrụ na nsogbu anọgide mgbe ị lechara ihe ndị a anya, gakwuru ọkachamara ọkụ eletrik ruru eru.

9. Nkọwapụta

NlereanyaCU4200
Ụdị6 Gang, 2 Way Switch
Ogo dị ugbu a10 Amperes (AX)
Voltage Ntụle250V ~
Akụkụ (L x W x D)14.6 cm x 8.6 cm x 2.1 cm (approximate depth to back base)
Ibu130 g
Ihe onwunwePlastic (White finish)
ỤkpụrụTS EN 60669-1

10. Akwụkwọ ikike na nkwado

This product is manufactured to high standards and is covered by a standard manufacturer's warranty. For specific warranty details, technical support, or to report any issues, please contact Knightsbridge customer service or refer to their official website. Please have your model number (CU4200) and purchase information available when contacting support.

Knightsbridge Contact Information: Please visit the official Knightsbridge websaịtị maka nkọwa kọntaktị kachasị ọhụrụ.

Akwụkwọ ndị emetụtara - CU4200

Tupuview Knightsbridge SK006 IP54 3-Gang Pop-Up Socket: Installation & Maintenance Manual
This manual provides comprehensive installation, operation, and maintenance instructions for the Knightsbridge SK006 IP54 3-Gang Pop-Up Socket. It covers safety precautions, installation steps, usage guidelines, warnings, and warranty information.
Tupuview Knightsbridge SKR008 / SKR009A Installation and Maintenance Manual
Detailed installation and maintenance guide for Knightsbridge SKR008 and SKR009A electrical sockets. Includes safety precautions, step-by-step installation instructions, wiring diagrams, and warranty information.
Tupuview Knightsbridge Electrical Accessories Installation and Safety Guide
Comprehensive guide to the safe installation and operation of Knightsbridge electrical accessories, including sockets, USB chargers, dimmers, and switches. Covers wiring, safety precautions, and product specifications.
Tupuview Knightsbridge 8300XX Electrical Switch Installation and Maintenance Manual
This document provides installation and maintenance instructions for the Knightsbridge 8300XX electrical switch. It covers safety precautions, installation steps, general care, and warranty information.
Tupuview Knightsbridge EX00xx Extractor Fan Installation & Maintenance Manual
Comprehensive installation and maintenance manual for Knightsbridge EX00xx series extractor fans (EX003T, EX004T, EX005T, EX006T). Includes safety guidelines, wiring instructions, timer adjustment, and warranty information for proper setup and care.
Tupuview Knightsbridge SK0010 Installation and Maintenance Manual
Comprehensive installation and maintenance guide for the Knightsbridge SK0010 dual USB charger, detailing safety precautions, installation steps, general care, and warranty information.