3M 2097

Ntuziaka Ntuziaka Maka Nzacha Mkpụrụ 3M 2097 P100 nke Nwere Ntuziaka Maka Mmiri Na-anaghị Eru Uzuoku nke Organic

Ụdị: 3M 2097

1. Okwu mmalite

The 3M 2097 P100 Particulate Filter with Organic Vapor Relief is designed to provide respiratory protection in various industrial and occupational environments. These filters are NIOSH approved for environments containing certain oil and non-oil based particles. They are also recommended by 3M for relief against nuisance levels of organic vapors and ozone protection up to 10 times the OSHA Permissible Exposure Limit (PEL). Please note that these filters are not NIOSH certified for use against ozone.

Ozi nchekwa dị mkpa

  • Debe ebe ụmụaka na-apụghị iru.
  • Zere kọntaktị na akpụkpọ na anya.
  • Jiri ya na mpaghara ikuku ikuku.
  • Wear protective clothing and eyewear as appropriate for the task.
  • Seek medical help if ingested or inhaled excessively.
  • Always read the product description and compatibility information thoroughly.
  • Ensure proper fitting with compatible 3M facepieces and cartridges.
  • Use only in described environments and applications. Avoid environments where the product is not designed to offer protection.

Disclaimer: 3M industrial and occupational products are intended for sale to trained industrial and occupational customers for workplace use. They are not intended for sale to or use by consumers for home, personal, or recreational uses. Misuse may result in injury, sickness, death, or property damage.

2. Ndakọrịta

The 3M 2097 P100 Particulate Filters are designed for use with specific 3M respirators and facepieces. Ensure your respirator system is compatible before use.

Compatible 3M Respirator Systems:

  • 3M Respirators 5000 Series
  • 3M Cartridge 6000 Series (when used with 3M Adapter 502)
  • 3M Facepieces 6000 Series (with bayonet filter holders)
  • 3M Facepieces 7000 Series (with bayonet filter holders)

These filters can be used with a wide variety of 3M's half and full facepiece designs that feature bayonet filter holders.

3. Setup and Attachment

Proper attachment of the 3M 2097 filters to your compatible 3M respirator is crucial for effective protection. Follow these steps:

  1. Align the filter with the bayonet attachment point on your respirator facepiece.
  2. Push the filter onto the attachment point and turn it approximately a quarter turn clockwise until it clicks into place.
  3. Ensure the filter is securely seated and cannot be easily removed by pulling gently. Both filters should be attached firmly.
  4. Perform a user seal check as instructed by your respirator's manual to confirm a proper fit.
Four 3M 2097 P100 Particulate Filters

Image 1: Four 3M 2097 P100 Particulate Filters. These purple, circular filters are designed for respiratory protection.

4. Operating Conditions and Applications

When properly fitted, the 3M 2097 P100 Particulate Filters can be used in a variety of applications where protection against certain particulates and nuisance levels of organic vapors is required.

Ngwa akwadoro:

  • ịgbado ọkụ
  • Na-agba ọsọ
  • Torch cutting
  • Metal pouring
  • Ịzụ ahịa
  • Exposure to lead, asbestos, cadmium, arsenic, and MDA

These filters provide protection for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. For full facepieces, quantitative fit testing is required to claim an assigned protection factor above 10 in negative pressure mode. Always refer to specific provincial regulations for appropriate assigned protection factors.

The filters also offer nuisance level relief from organic vapors that are below the PEL. Nuisance level refers to concentrations not exceeding OSHA PEL or other applicable government occupational exposure limits, whichever is lower.

Oke:

Do not use these filters for respiratory protection against acid gases or in environments that are immediately dangerous to life or health (IDLH).

5. Mmezi na Nchekwa

Regular inspection and proper storage of your 3M 2097 filters are essential to maintain their effectiveness.

Ndochi nzacha:

Replace filters when:

  • iku ume na-esi ike.
  • You detect the smell or taste of contaminants.
  • The filter becomes damaged or soiled.
  • According to your company's change-out schedule or local regulations.

Always replace both filters simultaneously to ensure balanced protection.

Nchekwa:

Store unused filters in their original packaging in a clean, dry environment away from contaminants and extreme temperatures. After use, if the filters are not to be immediately replaced, store the respirator with attached filters in a sealed bag or container to protect them from dust and damage.

6. Nchọpụta nsogbu

If you experience any issues while using the 3M 2097 P100 Particulate Filters, consider the following:

Detection of Contaminants (Smell/Taste):

If you smell, taste, or otherwise detect contaminants while wearing the respirator, or if irritation occurs, immediately leave the contaminated area. Check the fit of your respirator and the seal of the filters. If the issue persists, replace both filters. If the problem continues after filter replacement and fit check, consult your safety supervisor.

Iku ume siri ike:

If breathing becomes difficult, it may indicate that the filters are clogged with particulates. Immediately leave the contaminated area and replace both filters.

Na-ekwesịghị ekwesị:

An improper fit can compromise protection. Re-adjust your respirator and perform a user seal check. If a proper seal cannot be achieved, do not enter or remain in the contaminated area.

7. Nkọwapụta

3M 2097 P100 Particulate Filter with specifications listed

Image 2: A 3M 2097 P100 Particulate Filter shown alongside key specifications such as size, material, color, and model name.

NjirimaraNkọwa
Onye nrụpụta3M
Nọmba akụkụ2097-2
Nọmba Nlereanya ihe3M2097-2
Ibu Ibu3.13 ounces
Akụkụ ngwaahịa6 x 7.3 x 1.5 sentimita asatọ
NhaNha zuru oke
AgbaPurple
Ihe onwunwePolypropylene (PP)
Ọnụ ngwungwu ihe1 (nwere nzacha atọ)
Ngwa gụnyere2 (Two Pack Filters)

8. Akwụkwọ ikike Ozi

Specific warranty details for the 3M 2097 P100 Particulate Filters are not provided in the available product information. For warranty inquiries, please refer to the official 3M website or contact 3M customer support directly.

9. Nkwado na Ozi Ndị Ọzọ

For additional product information, technical assistance, or specific guidance on product selection and use, please consult the following resources:

  • Your on-site safety professional.
  • An industrial hygienist.
  • Other subject matter experts in respiratory protection.
  • Gaa leta 3M gọọmentị websaịtị: www.3M.com