Einhell GE-PP 1100 N-A

Einhell GE-PP 1100 N-A Stainless Steel Pressure Pump Instruction Manual

Model: GE-PP 1100 N-A

1. Okwu mmalite

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Einhell GE-PP 1100 N-A Stainless Steel Pressure Pump. Please read these instructions carefully before using the product and keep them for future reference. Proper use and adherence to safety guidelines will ensure optimal performance and longevity of the pump.

Einhell GE-PP 1100 N-A Stainless Steel Pressure Pump

Foto 1: The Einhell GE-PP 1100 N-A Stainless Steel Pressure Pump. This image displays the pump's cylindrical body, primarily red and silver, with a handle at the top and a perforated intake at the bottom.

2. Ntuziaka nchekwa

Always observe the following safety precautions to prevent injury and damage:

  • Ensure the power supply matches the pump's specifications.
  • Do not operate the pump with damaged cables or plugs.
  • Never lift the pump by its power cable.
  • Keep children and unauthorized persons away from the operating pump.
  • Disconnect the pump from the power supply before any maintenance or cleaning.
  • The pump is designed for pumping clear water only. Do not use it for flammable, corrosive, or explosive liquids.
  • Gbaa mbọ hụ na ikuku ikuku zuru oke mgbe ị na-arụ ọrụ.

3. Ngwaahịa gafereview

The Einhell GE-PP 1100 N-A is a robust stainless steel pressure pump designed for various water transfer applications, such as emptying rainwater butts, reservoirs, or garden fountains. It features an automatic function that turns the device on and off based on water demand. The pump is constructed with durable materials and incorporates important safety features.

Akụkụ ndị bụ isi:

  • Ọrụ ngbanwu/ gbanyụọ akpaaka: The pump activates and deactivates automatically with water demand.
  • Multi-level Pump Wheel System: Provides an extra-high supply pressure for efficient water delivery.
  • Igwe anaghị agba nchara Casing: Ensures durability and corrosion resistance.
  • High-Quality Mechanical Seal: Contributes to a long service life.
  • Nchekwa ịgba ọsọ akọrọ: Safeguards the pump from damage if the water supply is interrupted.
  • Overload Switch: Na-echebe moto site na ikpo oke ọkụ.
  • Easily Accessible Hose Connection: Located on the pump top for convenient setup.
Ọrụ ngbanwu/ gbanyụọ akpaaka

Foto 2: The 'AUTO ON/OFF' indicator on the pump. This image highlights the automatic control feature, which allows the pump to start and stop based on water demand.

Dry Running Protection Icon

Foto 3: Icon representing dry running protection. This symbol indicates the pump's safety feature that prevents damage when water levels are insufficient.

4. Nka na ụzụ nkọwa

NkọwapụtaUru
NlereanyaGE-PP 1100 NA
Isi Iyi IkeIgwe ọkụ eletrik
Wattage1100 W
Voltage230 V
Ọnụego nfe kacha6000 lita kwa elekere
Kachasị Elu Elu12 Meters (Immersion depth up to 12 meters)
Maximum Delivery Pressure4.5 mmanya
Ogologo nnyefe kacha45 mita
Akụkụ ngwaahịa (L x W x H)5.91" x 5.51" x 19.29" (ihe dị ka 15cm x 14cm x 49cm)
Ibu Ibu8.7 Kilogram (19.14 pound)
Ihe onwunweIgwe anaghị agba nchara
Ogologo eriri ike15 mita
Maximum Delivery Height 45m

Foto 4: Icon indicating a maximum delivery height of 45 meters. This graphic illustrates the vertical distance the pump can effectively push water.

Maximum Flow Rate 6000 l/h

Foto 5: Icon indicating a maximum flow rate of 6000 liters per hour. This image represents the volume of water the pump can move in one hour.

High Pressure Pump 4.5 bar

Foto 6: Icon indicating a high pressure pump with 4.5 bar. This graphic shows a pressure gauge, signifying the pump's capability to generate significant water pressure.

5. Nhazi

Follow these steps for proper installation and setup of your pressure pump:

  1. Iwepu: Carefully remove the pump from its packaging and inspect for any signs of damage.
  2. Nkwanye: Position the pump in a stable location within the water source. Ensure the pump is fully submerged and stands upright. The minimum operating space required is approximately 17 cm x 17 cm.
  3. Njikọ Hose: Connect a suitable hose to the pressure connection (33.3 mm / 1" female thread) located on the top of the pump. Secure the connection to prevent leaks.
  4. Njikọ ike: Plug the pump into a grounded electrical outlet that matches the specified voltage (230V). Ensure the power cable is not kinked or damaged.
Minimum Operating Space Diagram

Foto 7: Diagram illustrating the minimum operating space required for the pump. This image shows the pump submerged in water, indicating a minimum diameter of 17 cm for proper function.

Pressure Connection Detail

Foto 8: Agara nso view of the pressure connection with stainless steel insert. This image details the threaded outlet where the discharge hose is attached.

6. Ntuziaka ọrụ

The Einhell GE-PP 1100 N-A pump is designed for user-friendly operation with its automatic features.

  1. Mmalite mbụ: Once the pump is correctly installed and submerged, connect it to the power supply. The pump will automatically prime itself.
  2. Ọrụ akpaaka: The pump's integrated automatic function will detect water demand. When a tap or valve connected to the pump is opened, the pump will start. When the tap or valve is closed, the pump will automatically shut off after a short delay.
  3. Nchekwa ịgba ọsọ akọrọ: The pump is equipped with dry running protection. If the water level drops too low, the pump will automatically switch off to prevent damage. It will restart once sufficient water is available.
  4. Ojiji na-aga n'ihu: For immersion depths up to 12 meters, the pump can operate continuously, providing a consistent water supply.
Man operating Einhell pump in garden

Foto 9: A man lowering the Einhell pump into a well in a garden setting. This image demonstrates the typical use case of the pump for garden irrigation or water transfer from a source.

7. Nlekọta

Ndozi mgbe niile na-eme ka ọkpọkọ gị dị ogologo ma rụọ ọrụ nke ọma.

  • Nhicha: Periodically clean the pump's intake screen to prevent blockages. Disconnect power before cleaning.
  • Nchekwa oyi: Before the first frost, completely drain the pump of water to prevent freezing damage. Store the pump in a dry, frost-free location.
  • Nyocha: Regularly inspect the power cable and hose connections for wear or damage. Replace any damaged parts immediately.
Pump intake screen

Foto 10: Close-up of the pump's intake screen at the bottom. This image shows the perforated filter designed to prevent large debris from entering the pump mechanism.

Internal pump diagram

Foto 11: Cross-section diagram of the pump's internal components. This illustration provides a view of the multi-level pump wheel system and other internal mechanisms.

8. Nchọpụta nsogbu

This section addresses common issues you might encounter with your pump.

NsogbuIhe nwere ike imeNgwọta
Mgbapụta anaghị ebidoEnweghị ọkụ
Overload switch tripped
Agbanyere nchekwa ịgba ọsọ akọrọ
Check power connection and fuse
Allow pump to cool down, then restart
Ensure sufficient water level
Low pressure or flow rateIntake screen blocked
Hose kinked or too small diameter
Ikuku na usoro
Clean intake screen
Check hose for kinks, use appropriate diameter
Ensure pump is fully submerged and system is primed
Mgbapụta ọkụ na-aga n'ihuMbelata na sistem
Automatic function malfunction
Check all connections and hoses for leaks
Kpọtụrụ nkwado ndị ahịa ma ọ bụrụ na nsogbu ka dị
Pump switches off frequentlyLow water level (dry running protection)
Overheating (overload switch)
Gbaa mbọ hụ na enweta mmiri zuru oke
Allow pump to cool, check for blockages

9. Akwụkwọ ikike na nkwado

For warranty information and customer support, please refer to the documentation provided with your purchase or visit the official Einhell websaịtị. Debe ihe akaebe nke ịzụrụ ihe maka akwụkwọ ikike ọ bụla.

If you encounter issues not covered in this troubleshooting guide, please contact Einhell customer service for assistance. When contacting support, have your model number (GE-PP 1100 N-A) and serial number ready.

Akwụkwọ ndị emetụtara - GE-PP 1100 NA

Tupuview Einhell GE-PP 18 RB Li Akku-Tauchdruckpumpe: Bedienungsanleitung
Umfassende Bedienungsanleitung für die Einhell GE-PP 18 RB Li Akku-Tauchdruckpumpe. Erfahren Sie alles über Installation, sichere Bedienung, technische Daten und Wartung dieses kabellosen Geräts für Haus und Garten.
Tupuview Akwụkwọ ntuziaka ọrụ Einhell GE-CF 18/2200 Li Cordless Fan
Chọpụta ihe na-akwado Einhell GE-CF 18/2200 Li cordless fan. Akwụkwọ ntuziaka a na-arụ ọrụ na-akọwapụta atụmatụ ya maka ikuku ventilashị nke ụlọ, gụnyere ike ikuku, ọsọ a na-agbanwe agbanwe, na mbugharị. Mụta maka ọrụ nchekwa, mmezi na ozi ikike.
Tupuview Einhell GE-SP 18 Li Akku-Klarwasserpumpe Bedienungsanleitung
Die offizielle Bedienungsanleitung für die Einhell GE-SP 18 Li Akku-Klarwasserpumpe. Enthält detaillierte Informationen zu Sicherheit, Installation, Betrieb, Wartung und Fehlerbehebung für dieses leistungsstarke Gartengerät.
Tupuview Einhell GE-DP 7535 N LL ECO Schmutzwasserpumpe / Flutset Bedienungsanleitung
Diese Anleitung beschreibt die Bedienung und Wartung der Einhell GE-DP 7535 N LL ECO Schmutzwasserpumpe und des Flutsets. Sie enthält wichtige Sicherheitshinweise, technische Daten und Anleitungen zur Fehlerbehebung für den effizienten Einsatz der Pumpe.
Tupuview Einhell GE-WS 18/35 Li & GE-WS 18/75 Li Akku-Drucksprühgerät Bedienungsanleitung
Diese Bedienungsanleitung für die Einhell Akku-Drucksprühgeräte GE-WS 18/35 Li und GE-WS 18/75 Li bietet detaillierte Anleitungen zur sicheren Verwendung, Wartung und Fehlerbehebung dieser Gartengeräte.
Tupuview Einhell GE-CM 18/33 Li Akku-Rasenmäher Bedienungsanleitung
Diese Bedienungsanleitung bietet detaillierte Informationen zur sicheren und effektiven Nutzung des Einhell GE-CM 18/33 Li Akku-Rasenmähers, einschließlich Montage, Bedienung, Wartung na Fehlerbehebung.