1. Okwu mmalite
The Einhell GE-SP 3046 RB is a versatile multi-function pump designed for efficient rainwater collection and drainage. Its robust construction and intelligent features make it ideal for various applications around the home and garden, such as emptying rain barrels, tanks, or small ponds, and transferring water for irrigation. This manual will guide you through the proper use and care of your pump.

Figure 1.1: Einhell GE-SP 3046 RB Multi-function Pump with Accessories.
2. Ntuziaka nchekwa
Always read and follow all safety instructions before operating the pump.
- Gbaa mbọ hụ na ọkọnọ ike dabara na voltage specified on the pump's rating label.
- Never operate the pump with a damaged power cable or plug. Have any damage repaired by a qualified electrician.
- Ejila eriri ike ya bulie ma ọ bụ buru pamụpụ ahụ.
- Debe ụmụaka na ndị na-enyeghị ikike ka ha ghara ịnọ ebe a na-arụ ọrụ.
- Etinyela mmiri ọkụ, ihe na-emebi emebi, ma ọ bụ ihe na-agbawa agbawa n'ime mmiri.
- Ensure the pump is fully submerged in water during operation to prevent dry running and overheating.
- Disconnect the pump from the power supply before performing any maintenance, cleaning, or when not in use.
- Chebe mgbapụta ahụ site na ntu oyi.
3. Ngwa ngwaahịa
The Einhell GE-SP 3046 RB pump comes with several key components for its multi-functional use:
- Ngalaba mgbapụta: The main submersible pump with integrated motor and power cable.
- Mgbanwe n'elu mmiri: Automatically activates/deactivates the pump based on water level.
- Gooseneck na-agbanwe agbanwe: Allows for precise water discharge direction.
- Adjustable Aluminum Tube: Provides variable height for water extraction, especially from deep containers.
- Rain Stand: A stable base for positioning the pump and extension tube in rain barrels.
- Integrated Cable Rewind: Convenient storage for the power cable on the pump housing.
- Extension Tube Storage: Dedicated compartment on the pump housing for storing extension tubes.

Figure 3.1: Close-up of the Pump Unit.

Figure 3.2: Flexible Gooseneck.

Figure 3.3: Extension Tube Storage.
4. Nhazi
Follow these steps to set up your Einhell pump for operation:
- Assemble the Extension: If using the pump for rainwater collection from a barrel, attach the adjustable aluminum tube to the pump's outlet. Then, connect the flexible gooseneck to the top of the aluminum tube.
- Debe mgbapụta ahụ: Place the pump unit into the water source (e.g., rain barrel, tank, or flooded area). Ensure the pump is stable and fully submerged. The minimum operating space required is approximately 40 x 40 cm, with a pump diameter of 24 cm.
- Adjust the Float Switch: The float switch controls the automatic on/off function of the pump. Adjust its position along the cable to set the desired minimum and maximum water levels for operation. A higher float position will require more water to activate the pump.
- Jikọọ na Ike: Plug the pump's power cable into a properly grounded electrical outlet. Ensure the outlet is protected by a residual current device (RCD) for safety.

Figure 4.1: Minimum Operating Space.

Figure 4.2: Adjusting the Float Switch.
5. .rụ ọrụ
Once set up, the Einhell GE-SP 3046 RB pump operates efficiently:
- Ọrụ akpaaka: The pump will automatically start when the water level rises to the activation point set by the float switch and stop when the water level drops below the deactivation point.
- Ọrụ aka: For continuous operation regardless of water level (e.g., for complete drainage), the float switch can often be fixed in an 'on' position. Refer to the specific instructions for your float switch model.
- Water Transfer: Direct the flexible gooseneck or connected hose to where you want the water to be discharged. The pump can deliver up to 4,600 liters per hour with a maximum delivery height of 11 meters.

Figure 5.1: Pump in use for rainwater collection.
6. Nlekọta
Nlekọta oge niile na-eme ka ogologo ndụ na ịrụ ọrụ kacha mma nke mgbapụta gị:
- Nhicha: After each use, especially when pumping dirty water, rinse the pump with clean water. Remove any debris or foreign objects from the intake area at the bottom of the pump.
- Lelee maka ihe mgbochi: Periodically inspect the pump's intake and outlet for any blockages that could impede water flow.
- Nyocha USB: Regularly check the power cable for any signs of wear, cuts, or damage.
- Nchekwa oyi: Before the first frost, completely drain the pump of all water to prevent damage from freezing. Store the pump in a dry, frost-free location.
7. Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Mgbapụta anaghị ebido | Enweghị ọkụ Float switch not activated Moto jujuru/kpoo oke ọkụ | Check power connection and fuse Adjust float switch position or manually activate Disconnect power, let cool down, check for blockages |
| Obere eruba | Partial blockage in intake/outlet Hose kinked or too long/narrow Ọkwa mmiri ezughi oke | Clean intake and outlet Check hose for kinks, use appropriate diameter Ensure pump is adequately submerged |
| Mgbapụta ọkụ na-aga n'ihu | Switi mmiri ahụ rapaara n'ọnọdụ 'gbanyere' Water level not dropping below deactivation point | Check float switch for free movement Ensure proper float switch adjustment for deactivation |
8. Nkọwapụta
| Njirimara | Nkọwapụta |
|---|---|
| Nlereanya | GE-SP 3046 RB |
| Nọmba edemede | 4170438 |
| Ike | 350 W |
| Voltage | 230 V |
| Oke. Ọnụego mgbaba | 4,600 L/h (4.6 Litres per second) |
| Oke. Ogologo nnyefe | 11 m |
| Max. Impurity Size | 2.5 mm |
| Ogologo eriri USB | 10 m |
| Ihe onwunwe | Impact-resistant PVC Plastic |
| Ibu | 3.8 n'arọ |
| Akụkụ (L x W x H) | 17 x 23 x 51 cm |
9. Akwụkwọ ikike na nkwado
Einhell products are manufactured with high-quality materials and undergo strict quality controls. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Einhell website. For technical support, spare parts, or service inquiries, please contact Einhell customer service directly. Keep your purchase receipt as proof of purchase.