Einhell GE-SP 3046 RB

Einhell GE-SP 3046 RB Multi-function Rainwater Collector and Drainage Pump User Manual

Model: GE-SP 3046 RB (Article No.: 4170438)

1. Okwu mmalite

The Einhell GE-SP 3046 RB is a versatile multi-function pump designed for efficient rainwater collection and drainage. Its robust construction and intelligent features make it ideal for various applications around the home and garden, such as emptying rain barrels, tanks, or small ponds, and transferring water for irrigation. This manual will guide you through the proper use and care of your pump.

Einhell GE-SP 3046 RB pump with extension tube and float switch

Figure 1.1: Einhell GE-SP 3046 RB Multi-function Pump with Accessories.

2. Ntuziaka nchekwa

Always read and follow all safety instructions before operating the pump.

  • Gbaa mbọ hụ na ọkọnọ ike dabara na voltage specified on the pump's rating label.
  • Never operate the pump with a damaged power cable or plug. Have any damage repaired by a qualified electrician.
  • Ejila eriri ike ya bulie ma ọ bụ buru pamụpụ ahụ.
  • Debe ụmụaka na ndị na-enyeghị ikike ka ha ghara ịnọ ebe a na-arụ ọrụ.
  • Etinyela mmiri ọkụ, ihe na-emebi emebi, ma ọ bụ ihe na-agbawa agbawa n'ime mmiri.
  • Ensure the pump is fully submerged in water during operation to prevent dry running and overheating.
  • Disconnect the pump from the power supply before performing any maintenance, cleaning, or when not in use.
  • Chebe mgbapụta ahụ site na ntu oyi.

3. Ngwa ngwaahịa

The Einhell GE-SP 3046 RB pump comes with several key components for its multi-functional use:

  • Ngalaba mgbapụta: The main submersible pump with integrated motor and power cable.
  • Mgbanwe n'elu mmiri: Automatically activates/deactivates the pump based on water level.
  • Gooseneck na-agbanwe agbanwe: Allows for precise water discharge direction.
  • Adjustable Aluminum Tube: Provides variable height for water extraction, especially from deep containers.
  • Rain Stand: A stable base for positioning the pump and extension tube in rain barrels.
  • Integrated Cable Rewind: Convenient storage for the power cable on the pump housing.
  • Extension Tube Storage: Dedicated compartment on the pump housing for storing extension tubes.
Close-up of the Einhell GE-SP 3046 RB pump unit

Figure 3.1: Close-up of the Pump Unit.

Flexible gooseneck attachment for the pump

Figure 3.2: Flexible Gooseneck.

Storage compartment for extension tubes on the pump

Figure 3.3: Extension Tube Storage.

4. Nhazi

Follow these steps to set up your Einhell pump for operation:

  1. Assemble the Extension: If using the pump for rainwater collection from a barrel, attach the adjustable aluminum tube to the pump's outlet. Then, connect the flexible gooseneck to the top of the aluminum tube.
  2. Debe mgbapụta ahụ: Place the pump unit into the water source (e.g., rain barrel, tank, or flooded area). Ensure the pump is stable and fully submerged. The minimum operating space required is approximately 40 x 40 cm, with a pump diameter of 24 cm.
  3. Adjust the Float Switch: The float switch controls the automatic on/off function of the pump. Adjust its position along the cable to set the desired minimum and maximum water levels for operation. A higher float position will require more water to activate the pump.
  4. Jikọọ na Ike: Plug the pump's power cable into a properly grounded electrical outlet. Ensure the outlet is protected by a residual current device (RCD) for safety.
Diagram showing minimum operating space for the pump

Figure 4.1: Minimum Operating Space.

Image demonstrating how to adjust the float switch

Figure 4.2: Adjusting the Float Switch.

5. .rụ ọrụ

Once set up, the Einhell GE-SP 3046 RB pump operates efficiently:

  • Ọrụ akpaaka: The pump will automatically start when the water level rises to the activation point set by the float switch and stop when the water level drops below the deactivation point.
  • Ọrụ aka: For continuous operation regardless of water level (e.g., for complete drainage), the float switch can often be fixed in an 'on' position. Refer to the specific instructions for your float switch model.
  • Water Transfer: Direct the flexible gooseneck or connected hose to where you want the water to be discharged. The pump can deliver up to 4,600 liters per hour with a maximum delivery height of 11 meters.
Woman using the Einhell pump to collect rainwater from a barrel

Figure 5.1: Pump in use for rainwater collection.

6. Nlekọta

Nlekọta oge niile na-eme ka ogologo ndụ na ịrụ ọrụ kacha mma nke mgbapụta gị:

  • Nhicha: After each use, especially when pumping dirty water, rinse the pump with clean water. Remove any debris or foreign objects from the intake area at the bottom of the pump.
  • Lelee maka ihe mgbochi: Periodically inspect the pump's intake and outlet for any blockages that could impede water flow.
  • Nyocha USB: Regularly check the power cable for any signs of wear, cuts, or damage.
  • Nchekwa oyi: Before the first frost, completely drain the pump of all water to prevent damage from freezing. Store the pump in a dry, frost-free location.

7. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Mgbapụta anaghị ebidoEnweghị ọkụ
Float switch not activated
Moto jujuru/kpoo oke ọkụ
Check power connection and fuse
Adjust float switch position or manually activate
Disconnect power, let cool down, check for blockages
Obere erubaPartial blockage in intake/outlet
Hose kinked or too long/narrow
Ọkwa mmiri ezughi oke
Clean intake and outlet
Check hose for kinks, use appropriate diameter
Ensure pump is adequately submerged
Mgbapụta ọkụ na-aga n'ihuSwiti mmiri ahụ rapaara n'ọnọdụ 'gbanyere'
Water level not dropping below deactivation point
Check float switch for free movement
Ensure proper float switch adjustment for deactivation

8. Nkọwapụta

NjirimaraNkọwapụta
NlereanyaGE-SP 3046 RB
Nọmba edemede4170438
Ike350 W
Voltage230 V
Oke. Ọnụego mgbaba4,600 L/h (4.6 Litres per second)
Oke. Ogologo nnyefe11 m
Max. Impurity Size2.5 mm
Ogologo eriri USB10 m
Ihe onwunweImpact-resistant PVC Plastic
Ibu3.8 n'arọ
Akụkụ (L x W x H)17 x 23 x 51 cm

9. Akwụkwọ ikike na nkwado

Einhell products are manufactured with high-quality materials and undergo strict quality controls. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Einhell website. For technical support, spare parts, or service inquiries, please contact Einhell customer service directly. Keep your purchase receipt as proof of purchase.

Akwụkwọ ndị emetụtara - GE-SP 3046 RB

Tupuview Einhell GE-SP 18 Li Akku-Klarwasserpumpe Bedienungsanleitung
Die offizielle Bedienungsanleitung für die Einhell GE-SP 18 Li Akku-Klarwasserpumpe. Enthält detaillierte Informationen zu Sicherheit, Installation, Betrieb, Wartung und Fehlerbehebung für dieses leistungsstarke Gartengerät.
Tupuview Ntuziaka Ọrụ nke Einhell GE-CL 36 Li E Igwe Afụ Oyi Na-enweghị Ikuku
Ntuziaka zuru oke maka ọrụ na ntuziaka nchekwa maka Einhell GE-CL 36 Li E Cordless Blower Vac, nhazi zuru oke, ojiji, mmezi, na nsogbu nsogbu.
Tupuview Einhell GE-LM 36/4in1 Li Aku-Multifunktionswerkzeug Bedienungsanleitung
Umfassende Bedienungsanleitung für das Einhell GE-LM 36/4in1 Li Akku-Multifunktionswerkzeug. Erfahren Sie mehr über Funktionen, Montage, Bedienung und Sicherheit dieses vielseitigen Gartengeräts.
Tupuview Einhell GE-CM 18/30 Li Cordless Lawn Mower: Operating Manual
Comprehensive operating instructions and safety guide for the Einhell GE-CM 18/30 Li cordless lawn mower. Learn about setup, operation, maintenance, and troubleshooting for your garden tool.
Tupuview Einhell GE-SP 18 Li Akku-Klarwasserpumpe: Bedienungsanleitung & Sicherheitshinweise
Umfassende Bedienungsanleitung für die Einhell GE-SP 18 Li Akku-Klarwasserpumpe. Erfahren Sie alles über sichere Handhabung, Installation, technische Daten, Wartung und Fehlerbehebung für Ihre Einhell Pumpe.
Tupuview Einhell GE-DP 18/25 LL Li Akku-Schmutzwasserpumpe Bedienungsanleitung
Entdecken Sie die Einhell GE-DP 18/25 LL Li, eine leistungsstarke Akku-Schmutzwasserpumpe für Haus und Garten. Diese Anleitung bietet detaillierte Informationen zur sicheren Installation, Bedienung und Wartung für optimale Leistung.