This manual provides comprehensive instructions for the installation, operation, and maintenance of the REDARC Smart Start SBI12 12V 100A Battery Isolator. The SBI12 is a microprocessor-controlled device designed to manage dual battery systems by protecting the primary (start) battery from excessive discharge while allowing the auxiliary battery to power non-essential loads. It functions as a solenoid priority system, ensuring efficient charging of your secondary battery when the vehicle is in motion.

2. Ngwaahịa gafereview

The REDARC Smart Start SBI12 offers advanced battery management for 12V dual battery systems, providing a continuous rating of 100A. Key features include:

Unlike diode-type isolators, the SBI12 avoids voltage drop issues, ensuring more efficient power transfer.

3. Ozi nchekwa

Please read and understand all safety warnings and instructions before installing or operating the REDARC Smart Start SBI12. Failure to do so may result in injury, damage to the product, or damage to your vehicle.

4. Ntọala na nwụnye

Proper installation is crucial for the optimal performance and longevity of your SBI12. The unit should be mounted securely in a dry, well-ventilated area, away from direct heat sources.

4.1 njirimara akụrụngwa

REDARC Smart Start SBI12 front view

Foto nke 4.1.1: N'ihu view of the REDARC Smart Start SBI12 battery isolator, showing the red housing with the REDARC logo and "Designed and manufactured in Australia" text, along with the main terminals and wiring connections.

REDARC Smart Start SBI12 side view

Foto nke 4.1.2: Akụkụ view of the REDARC Smart Start SBI12, illustrating the compact design and the robust terminals with protective caps.

REDARC Smart Start SBI12 alternate side view

Foto nke 4.1.3: Akụkụ ọzọ view of the REDARC Smart Start SBI12, highlighting the wiring connections including the ground wire labeled "GND".

4.2 eserese waya

The following diagram illustrates a standard installation for the Smart Start SBI12 in a dual battery system.

Smart Start standard installation wiring diagram

Foto nke 4.2.1: Standard installation wiring diagram for the REDARC Smart Start SBI12. It shows the connection between the start battery and the auxiliary battery via the SBI12, with fuses on both positive lines and ground connections for both batteries and the isolator.

4.3 Nyochaa nwụnye tupu etinye ya

5. Ntuziaka ọrụ

The REDARC Smart Start SBI12 operates automatically to manage your dual battery system.

6. Nlekọta

The REDARC Smart Start SBI12 is designed for minimal maintenance. However, periodic checks are recommended to ensure optimal performance:

7. Nchọpụta nsogbu

The SBI12 incorporates fault detection and an LED indicator to assist with troubleshooting.

Symptom / LED IndicationIhe nwere ike imeNgwọta
SBI12 not engaging (auxiliary battery not charging)
  • Primary battery voltage dị ala.
  • Njikọ ndị rụrụ arụ ma ọ bụ ndị mebiri emebi.
  • Fọpụ gbawara agbawa.
  • Faulty ground connection.
  • Check primary battery charge.
  • Inspect and clean all connections.
  • Lelee ma dochie fiusi ma ọ bụrụ na ọ dị mkpa.
  • Verify ground connection integrity.
LED indicates fault (e.g., flashing pattern)
  • Voltage drop detected.
  • N'elu voltage ọnọdụ.
  • Excessive current draw.
  • Mmejọ nke ime.
  • Check wiring for resistance, ensure proper gauge.
  • Verify vehicle charging system output.
  • Reduce load on auxiliary battery or check for short circuits.
  • Contact REDARC support if issues persist after checking external factors.
SBI12 remains engaged when engine is off
  • Ngalaba na-adịghị mma.
  • Wiring na -ezighi ezi.
  • Chọpụta waya ahụ site na eserese.
  • Contact REDARC support.

For detailed fault code interpretations or persistent issues, refer to the official REDARC documentation or contact their technical support.

8. Nkọwapụta

Nọmba nlereanyaSBI12
ỤdịREDRC
Voltage12 volts DC
Ogo na-aga n'ihu100 Amps
Ibu Ibu9.1 ounces (ihe dị ka gram 258)
Akụkụ ngwugwu3.7 x 2.99 x 2.95 sentimita (ihe dịka 9.4 x 7.6 x 7.5 cm)
Nọmba nke onye nrụpụtaSBI12

9. Akwụkwọ ikike na nkwado

For specific warranty information, please refer to the documentation provided with your REDARC Smart Start SBI12 or visit the official REDARC websaịtị.

If you require technical assistance, have questions about installation, or need help choosing the best dual battery setup for your needs, REDARC offers support resources.

REDARC Support:

Akwụkwọ ndị emetụtara - SBI12

Tupuview REDARC Smart Start SBI Smart Battery Isolator Installation and User Manual
Comprehensive guide to the REDARC Smart Start SBI Smart Battery Isolator, covering product function, safety warnings, installation, wiring diagrams, fault indication, troubleshooting, FAQs, and technical specifications. Essential for multi-battery vehicle systems.
Tupuview REDARC Smart Start Battery Isolator SBI12, SBI24, SBI212, SBI224 - Installation, Operation, and Safety Manual
Comprehensive guide for the REDARC Smart Start Battery Isolator, covering models SBI12, SBI24, SBI212, SBI224, and dual sensing variants. Includes specifications, installation instructions, wiring diagrams, fault diagnosis, FAQs, safety precautions, and warranty information.
Tupuview REDARC BCDC and SBI Wiring Diagrams for Dual Battery and Jump Start Systems
Detailed wiring diagrams for REDARC BCDC1240, BCDC2420, and SBI12 units, illustrating dual battery configurations, parallel/series connections, and 12V/24V jump start setups.
Tupuview Ngwa nrụnye GPC maka REDRC ALPHA R 50A - INEOS GRENADIER Ntuziaka nwụnye
Ntuzi nrụnye zuru ezu maka ngwa mgbanye GPC maka sistemu batrị REDRC ALPHA R 50A, kpọmkwem maka ụgbọ ala INEOS GRENADIER. Gụnyere ntuziaka site-nzọụkwụ, ịdọ aka ná ntị nchekwa, yana nkọwa inye ọrụ.
Tupuview REDRC 12V ruo 24V Single Circuit Voltage Boosters: VI180D, VI360D, VI720D akwụkwọ ntuziaka onye ọrụ
Akwụkwọ a na-enye nkọwa zuru ezu, atụmatụ, ntụzịaka nwụnye, na ozi akwụkwọ ikike maka REDRC's VI Series 12V ruo 24V Single Circuit Vol.tage Boosters, gụnyere ụdị VI180D, VI360D, na VI720D.
Tupuview REDARC ALPHA 50 BCDC Ntuziaka nwụnye
Ntuziaka nwụnye maka REDRC ALPHA 50 BCDC igwe igwe na-ebunye sistemu batrị abụọ, na-enye ntuziaka nzọụkwụ site na nzọụkwụ, ngwaọrụ ndị achọrọ, ihe ndị agụnyere, yana ntuziaka wiring maka ngwa ụgbọ ala.