Okwu mmalite
This manual provides detailed instructions for the safe and efficient operation of your Olimpia Splendid New Íssimo Portable Air Conditioner. Please read it thoroughly before use and retain it for future reference. This appliance is designed to provide cooling, dehumidification, and ventilation for indoor spaces.
Ihe ngwugwu
Hụ na ihe niile edepụtara n'okpuru dị na ngwugwu ahụ:
- 1 x Olimpia Splendid New Íssimo Portable Air Conditioner (220V)
- 1 x Flexible Exhaust Tube (1.5 meters)
- 1 x Njikwa anya
- 1 x Carbon Filter
- 1 x Window Kit (Ruler/Sliding Bar)
- 1 x Akwụkwọ ntuziaka (akwụkwọ a)
Njirimara ngwaahịa
The Olimpia Splendid New Íssimo Portable Air Conditioner offers several features for enhanced comfort and convenience:
- Confort Function: Automatically adjusts operation based on ambient room temperature for optimal comfort.
- Night Function: Maintains the set temperature for one hour, then increases it by 2 degrees Celsius in the subsequent hour. After the second hour, the temperature remains constant.
- Njikwa anya: Features a large display for easy function selection and timer programming (on/off). Operates up to 8 meters.
- Adjustable Air Vanes: Direct the airflow as needed.
- Ihe nzacha ikuku: Integrated air filter with a grid for easy maintenance.
- Ọrụ akpaaka: Simplifies operation.
- Stand By Key: For quick power management.
- Dehumidification and Ventilation Functions: Beyond cooling, the unit can dehumidify and circulate air.
- 3 Fan ngwa ngwa: Choose from low, medium, or high fan speeds.
- 2 Nhọrọ mmemme: Na-enye ohere maka ọrụ a haziri ahazi.
- Oke okpomọkụ: Operates within a temperature range of 18°C to 30°C.
- Aka nwere ike iweghachi: For easy transport, similar to a travel suitcase.
Melite
1. Ịwepu ma na-edobe ya
Carefully remove the air conditioner from its packaging. Place the unit on a flat, stable surface. Ensure there is at least 30 cm (12 inches) of clear space around the unit for proper airflow. The unit is equipped with wheels for easy movement.

Foto nke 1: The portable air conditioner placed in a room, demonstrating suitable positioning near a window for exhaust.
2. Exhaust Tube Installation
The portable air conditioner requires an exhaust tube to expel hot air outside. Connect one end of the flexible exhaust tube to the air outlet on the back of the unit. Extend the other end of the tube to a window or a suitable opening. Use the provided window kit (ruler/sliding bar) to secure the exhaust tube in the window opening, ensuring a tight seal to prevent hot air from re-entering the room.

Foto nke 2: Close-up of the portable air conditioner, highlighting the air outlet where the exhaust tube connects.
3. Njikọ ike
Plug the power cord into a grounded 220V electrical outlet. Ensure the outlet meets the power requirements of the unit.
Ntuziaka ọrụ
1. Gbanyụọ / gbanyụọ
Pịa Kwụrụ n'ụsọ bọtịnụ na akara njikwa ma ọ bụ remote control gbanye ma ọ bụ gbanyụọ unit.
2. Nhọrọ mode
Pịa Ụdị bọtịnụ ka ịgbagharị site na ụdị ọrụ dịnụ:
- Ọnọdụ Cool: For cooling the room. Set your desired temperature between 18°C and 30°C.
- Ụdị wepụ iru mmiri: Reduces humidity in the air without significant cooling.
- Fan Ọnọdụ: Na-ekesa ikuku n'enweghị oyi ma ọ bụ na-eme ka mmiri ghara ịdị.
3. Temperature and Fan Speed Adjustment
In Cool Mode, use the Okpomọkụ Elu/ala buttons on the control panel or remote to set the desired temperature. In Fan Mode, use the Ọsọ fan button to select between 3 speeds (low, medium, high).
4. Confort Function
Tinye ihe Nkasi obi function for automatic temperature adjustment based on the ambient environment.
5. Night Function
Tinye aka na Abali function for a gradual temperature increase during sleep. The temperature will increase by 1°C after the first hour and another 1°C after the second hour, then maintain this new temperature.
6. Ọrụ ngụ oge
Jiri ihe Ngụ oge button on the remote control to program the unit to turn on or off automatically after a set period (up to 2 programming options).
7. Adjusting Air Vanes
Manually adjust the horizontal and vertical air vanes on the front of the unit to direct the airflow as desired.
Nlekọta
1. Na-ehicha ihe nzacha ikuku
Regular cleaning of the air filter is essential for efficient operation. The filter is located behind a grid on the unit. Turn off and unplug the unit before cleaning. Remove the filter and wash it with lukewarm water and a mild detergent. Rinse thoroughly and allow it to air dry completely before reinserting. Clean the filter every two weeks or more frequently depending on usage and air quality.
2. Mgbapu mmiri
During dehumidification or cooling, water condensation will accumulate inside the unit. The unit has an internal reservoir. When the reservoir is full, the unit may stop operating and display an indicator. To drain the water, place a shallow pan or tray under the drainage outlet (usually located at the bottom rear of the unit). Remove the drain plug to allow water to flow out. Replace the plug securely once drained. Regular draining is recommended to prevent overflow and maintain efficiency.
Nchọpụta nsogbu
Tupu ịkpọtụrụ nkwado ndị ahịa, biko rụtụ aka na nsogbu na azịza ndị a na-ahụkarị:
- Otu anaghị agbanwuo:
- Gbaa mbọ hụ na etinyere eriri ike na nchekwa 220V.
- Lelee ma ihe nkesa sekit akwụsịla.
- Verify the unit is not in Stand By mode.
- Unit is running but not cooling:
- Check if the unit is in Cool Mode and the temperature setting is lower than the ambient room temperature.
- Ensure the exhaust hose is properly installed and sealed to expel hot air outside.
- Clean the air filter, as a clogged filter can restrict airflow and reduce cooling efficiency.
- Check if the water tank is full and needs draining.
- Gbaa mbọ hụ na emechiela windo na ọnụ ụzọ ka ikuku ọkụ ịbata n'ime ụlọ ahụ.
- Nkeji na-eme mkpọtụ:
- Ensure the unit is placed on a flat, stable surface to minimize vibrations.
- Check for any obstructions near the air intake or exhaust vents.
- A slight gurgling sound is normal and indicates refrigerant circulation.
- Mgbapu mmiri:
- Ensure the drain plug is securely in place.
- If continuous drainage is set up, check the drain hose for kinks or blockages.
Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nlereanya | New Íssimo 14000 BTUs |
| Ike jụrụ oyi | 14,000 BTU |
| Voltage | 220V |
| Ogologo | 480 mm (18.9 sentimita asatọ) |
| Obosara | 530 mm (20.9 sentimita asatọ) |
| Omimi | 590 mm (23.2 sentimita asatọ) |
| Ibu | 31 n'arọ (68.3 lbs) |
| Oke okpomọkụ | 18°C ruo 30°C |
| Ọsọ ndị fan | 3 |
| Oke njikwa anya | Ruo mita 8 |
Ozi akwụkwọ ikike
This Olimpia Splendid New Íssimo Portable Air Conditioner comes with a Akwụkwọ ikike nke ọnwa 12 from the date of purchase. This warranty covers manufacturing defects and faulty materials under normal use. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by misuse, improper installation, accidents, or unauthorized repairs.
Nkwado ndị ahịa
For technical assistance, warranty claims, or any questions regarding your Olimpia Splendid New Íssimo Portable Air Conditioner, please contact our customer support:
Ekwentị: 0800 77 06 222
Biko mee ka ụdị ngwaahịa gị na ụbọchị ịzụrụ ya dị mgbe ị na-akpọtụrụ ndị na-akwado ya.





