1. Ngwaahịa gafereview
The Toyama TD 5500 SGE is a silent series diesel generator, enclosed in a cabin for reduced noise. It is equipped with a 10HP engine and electric start, providing a maximum power output of 5.8 KVA and a nominal power output of 5.0 KVA. This bivolt (dual voltage) generator features a 16-liter fuel tank, offering approximately 7.6 hours of autonomy. It is designed for reliable power generation in various applications.

Foto 1: N'ihu view of the Toyama TD 5500 SGE Diesel Generator, showing the control panel, fuel cap, and wheels.
2. Ntọala na nwụnye
Nhazi nke ọma dị oke mkpa maka ịrụ ọrụ nchekwa na nke ọma. Soro usoro ndị a nke ọma:
- Iwepu: Carefully remove the generator from its packaging. Inspect for any shipping damage. Retain packaging materials for future transport or storage.
- Nkwanye: Position the generator on a firm, level surface outdoors, away from windows, doors, and vents to prevent carbon monoxide accumulation. Ensure adequate ventilation and clearance from combustible materials (at least 1 meter on all sides).
- Wheel Assembly (if not pre-assembled): Attach the wheels and handles according to the diagrams in the separate assembly guide (if provided).
- Tinye mmanụ igwe: Before first use, fill the engine crankcase with the recommended type and amount of diesel engine oil. Refer to the oil dipstick for the correct level. Do not overfill.
- Tinye mmanụ ụgbọala: Fill the fuel tank with clean, fresh diesel fuel. Do not use gasoline or other fuels. Ensure the fuel cap is securely tightened after filling. The tank capacity is 16 liters.
- Battery Connection (for Electric Start): Connect the battery cables to the generator's battery terminals, ensuring correct polarity (positive to positive, negative to negative).
- Nda ala: Connect a grounding wire from the generator's grounding terminal to a suitable earth ground rod. This is a critical safety measure.
3. Ntuziaka ọrụ
Soro usoro ndị a maka nchekwa na arụmọrụ dị irè nke jenereta gị:
3.1 Ndepụta nyocha tupu mmalite
- Lelee ọkwa mmanụ engine.
- Lelee ọkwa mmanụ ụgbọala.
- Ensure all electrical loads are disconnected from the generator outlets.
- Verify proper grounding.
- Confirm generator is on a level surface with adequate ventilation.
3.2 Ịmalite Generator (Mmalite Eletriki)
- Tụgharịa valvụ mmanụ ọkụ na ọnọdụ "ON".
- Ensure the engine switch is in the "ON" or "RUN" position.
- Insert the key into the ignition switch and turn it to the "START" position. Hold until the engine starts (typically a few seconds). Do not crank for more than 5 seconds at a time; allow a 10-second cool-down period between attempts.
- Once the engine starts, release the key, and it will return to the "ON" position.
- Allow the generator to warm up for a few minutes before connecting any electrical loads.
3.3 Ijikọ ibu eletrik
- Connect appliances or extension cords to the generator's outlets.
- Ejila jenereta ahụ mee ihe karịrị akarị. Oke mmiri ya niiletage of connected devices must not exceed the generator's nominal power output (5.0 KVA or 5000 Watts).
- Na-eji ụdọ ndọtị dị oke arụ ọrụ mgbe niile na mpụga.
3.4 Mechie Generator
- Kwụpụ ibu ọkụ eletrik niile na ebe a na-esi enweta ihe na-enye ọkụ eletrik.
- Kwe ka generator na-agba ọsọ nkeji ole na ole n'ebughị ibu ka ọ dajụọ.
- Tụgharịa ngbanwe engine gaa na ọnọdụ "gbanyụọ".
- Tụgharịa valvụ mmanụ ụgbọala ahụ ka ọ dị n'ọnọdụ "GBANYỤ".
4. Nlekọta
Regular maintenance ensures the longevity and reliable performance of your generator. Always perform maintenance with the engine off and cool.
4.1 Daily/Before Each Use
- Lelee ọkwa mmanụ engine.
- Lelee ọkwa mmanụ ụgbọala.
- Inspect for any visible leaks (fuel, oil).
- Check air filter for excessive dirt.
4.2 Every 50 Hours or Monthly
- Gbanwee mmanụ injin.
- Hichaa ma ọ bụ dochie ihe nzacha ikuku.
- Inspect and clean spark plug (if applicable, though diesel engines typically use glow plugs).
- Check battery terminals for corrosion and ensure connections are tight.
4.3 Every 200 Hours or Annually
- Dochie nzacha mmanụ ụgbọala.
- Inspect fuel lines for cracks or damage.
- Check valve clearance (should be performed by a qualified technician).
- Clean cooling fins and air passages.
For detailed maintenance procedures and specific oil/filter types, refer to the complete service manual or consult a certified Toyama service center.
5. Nchọpụta nsogbu
This section provides solutions to common operational issues. For problems not listed here, contact Toyama customer support.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Igwe agaghị amalite | Enweghị mmanụ ụgbọala Ọkwa mmanụ dị ala Battery discharged (electric start) Gbanyụọ injin Gbanyụọ valvụ mmanụ | Tinye mmanụ dizel Tinye mmanụ engine ka ọ dị mma Fanye ma ọ bụ dochie batrị Tụgharịa mgba ọkụ injin ka ọ bụrụ ON Turn fuel valve to ON |
| Low power output / Engine stalls under load | Ibu ibu Nzacha ikuku ruru unyi Mmanụ ụgbọala ochie ma ọ bụ nke ruru unyi | Belata ibu ejikọrọ Hichaa ma ọ bụ dochie ihe nzacha ikuku Drain old fuel and refill with fresh diesel |
| Generator produces no power | Ihe mgbawa sekit kwụsịrị Njikọ rụrụ arụ | Tọgharịa ihe mgbaji sekit Lelee njikọ eletrik niile |
| Nnukwu anwụrụ ọkụ sitere na iyuzucha | Overfilled oil Mmanụ ụgbọala na-ezighi ezi Igwe anaghị arụ ọrụ | Wepu mmanụ gabiga ókè Use correct diesel fuel Kpọtụrụ onye ọrụ nka tozuru oke |
6. Nka na ụzụ nkọwa
| Nkọwapụta | Uru |
|---|---|
| Onye nrụpụta | Toyama |
| Nlereanya | TD 5500 SGE |
| Ụdị Engine | 10HP Diesel Engine |
| Sistemụ mmalite | Eletriki Mmalite |
| Mbupute ike kacha | 5.8 KVA |
| Mmepụta Ike aha | 5.0 KVA |
| Voltage | Bivolt (Dual Voltage) |
| Ike tank mmanụ | 16 lita |
| Approximate Autonomy | awa 7.6 |
| Akụkụ ngwaahịa (L x W x H) | 95 cm x 60 cm x 80 cm |
| Ibu ngwaahịa | 175 n'arọ (175000 grams) |
| ASIN | B076KSRMDR |
| EAN | 7898438023776 |
7. Akwụkwọ ikike na nkwado
For information regarding the product warranty, please refer to the warranty card included with your generator or visit the official Toyama website. For technical support, spare parts, or service inquiries, please contact an authorized Toyama service center or your point of purchase.
Always provide your product model number (TD 5500 SGE) and serial number when contacting support to ensure efficient service.