Immergas 3027368

Immergas Victrix Tera 24KW Condensing Boiler User Manual

Ụdị: 3027368

1. Okwu mmalite

This manual provides essential information for the safe and efficient operation of your Immergas Victrix Tera 24KW Condensing Boiler. It is crucial to read and understand all instructions before installation, operation, or maintenance. Keep this manual in a safe place for future reference.

Ngwaahịa gafereview

The Immergas Victrix Tera 24KW is a high-efficiency condensing boiler designed for domestic heating and hot water production. Its advanced technology ensures optimal performance and energy savings.

Immergas Victrix Tera 24KW Condensing Boiler, front view

Foto 1: N'ihu view of the Immergas Victrix Tera 24KW Condensing Boiler, showing the control panel and pressure gauge. This image illustrates the compact design and user interface of the unit.

2. Ozi nchekwa

Safety is paramount when dealing with gas appliances. Failure to follow these instructions could result in property damage, personal injury, or death.

3. Nhazi

Installation should only be performed by a qualified heating engineer.

Nlebanya mbụ etinyere:

Installation Steps (Summary for reference):

  1. Ịkwanye: Securely mount the boiler to a suitable wall using the provided template and fixings. Ensure it is level.
  2. Sistemu flue: Install the flue system according to manufacturer's instructions and local regulations for safe exhaust of combustion products.
  3. Njikọ hydraulic: Connect the heating flow and return pipes, domestic hot water inlet and outlet, and condensate drain. Ensure all connections are watertight.
  4. Njikọ gas: Connect the gas supply line to the boiler's gas inlet, ensuring a gas-tight seal and proper isolation valve installation.
  5. Njikọ eletrik: Connect the boiler to the main electrical supply via a fused spur, following the wiring diagram in the full installation manual.
  6. Filling and Purging: Fill the heating system with water and thoroughly purge air from the system. Check for leaks.
  7. Ịnye ọrụ: A qualified engineer must perform the initial commissioning, including gas pressure checks, combustion analysis, and functional tests.

4. Ntuziaka ọrụ

Once installed and commissioned by a professional, operating your Immergas boiler is straightforward.

Ogwe njikwa gafereview:

The boiler features a digital display and several buttons for adjusting settings. Refer to the detailed diagram in the full manual for specific button functions.

Nrụ ọrụ bụ isi:

  1. Gbanyụọ/ Gbanyụọ: Use the main power switch (usually located near the boiler) to turn the unit on or off. The display will illuminate when powered on.
  2. Heating Temperature Adjustment: Use the '+' and '-' buttons, typically marked with a radiator icon, to set your desired central heating temperature.
  3. Domestic Hot Water (DHW) Temperature Adjustment: Use the '+' and '-' buttons, typically marked with a tap icon, to set your desired domestic hot water temperature.
  4. Ụdị arụ ọrụ: The boiler may have different operating modes (e.g., Summer, Winter, Auto). Select the appropriate mode using the mode selection button.
  5. System Pressure Check: Regularly observe the pressure gauge on the boiler. The optimal pressure range is typically between 1.0 and 1.5 bar when the system is cold. If the pressure drops below 1.0 bar, repressurize the system using the filling loop (refer to the full manual for detailed instructions).

Koodu mperi:

If an issue occurs, the boiler's display may show an error code. Note down the code and consult the troubleshooting section of this manual or the comprehensive error code list in the full Immergas manual. Do not attempt repairs yourself; contact a qualified technician.

5. Nlekọta

Regular maintenance ensures the longevity, efficiency, and safe operation of your Immergas boiler.

6. Nchọpụta nsogbu

Before calling a service technician, you can perform some basic checks for common issues.

NsogbuIhe nwere ike imeNgwọta
No heating or hot waterNo power, low system pressure, thermostat setting too low, gas supply off.Check power supply, check pressure gauge and repressurize if needed, adjust thermostat, ensure gas valve is open.
Usoro nrụgide dị alaMinor leak, system not adequately filled.Repressurize the system using the filling loop. If pressure drops frequently, contact a qualified technician for leak detection.
Boiler making unusual noisesAir in the system, limescale build-up, pump issue.Bleed radiators to remove air. For persistent noises or suspected limescale, contact a qualified technician.
Boiler displaying an error codeInternal fault, sensor issue, component failure.Note the error code. Attempt to reset the boiler (refer to full manual). If the code persists, contact a qualified Immergas service technician, providing the error code.

Ihe dị mkpa: For any issue not resolved by these basic steps, or if you are unsure, always contact a qualified and certified heating engineer. Do not attempt complex repairs yourself.

7. Nkọwapụta

Key technical specifications for the Immergas Victrix Tera 24KW Condensing Boiler:

Onye nrụpụtaImmergas
Akụkụ ngwaahịa (L x W x H)40 x 30 x 76 cm
Nọmba Nlereanya ihe3027368
NhaObere
AgbaBianco (Ọcha)
Ụdị24 kW
Ọnụọgụ nke ihe1
Ngwa gụnyereIgwe mmiri ọkụ
Batrị gụnyereMba
Batrị achọrọMba
Ibu36 grams
Nnweta akụkụ mapụtaraOzi adịghị na akụkụ mapụtara
Ụbọchị mbụ dị na Amazon.com.beEprel 25, 2022
Onye nrụpụta kwụsịrịMba

8. Akwụkwọ ikike na nkwado

Your Immergas Victrix Tera 24KW Condensing Boiler is covered by a manufacturer's warranty. The specific terms and duration of the warranty may vary by region and purchase date. Please refer to the warranty card included with your product or visit the official Immergas websaịtị maka ozi zuru ezu.

Nkwado ndị ahịa:

For technical assistance, spare parts, or warranty claims, please contact your authorized Immergas dealer or a certified service center. Ensure you have your boiler's model number (3027368) and serial number ready when contacting support.

For general inquiries, you may also visit the official Immergas website or consult their local distributors for contact information.