The Physio Logic Accuflex 5VU Digital Thermometer is designed to provide accurate and rapid temperature readings. This device features a flexible tip for comfort, a large backlit display for easy reading, and a Color Feverline alert system to indicate temperature status. It is suitable for oral, axillary (underarm), and rectal use. Please read this manual thoroughly before use to ensure proper operation and care.

Physio Logic Accuflex 5VU Digital Thermometer

Image: Physio Logic Accuflex 5VU Digital Thermometer. This image shows the digital thermometer with its flexible tip, large display, and color-coded fever indicator on the left side of the screen.

Ozi nchekwa dị mkpa

  • Do not boil the thermometer.
  • Do not allow children to take their temperature unsupervised.
  • Avoid dropping the thermometer or exposing it to severe shocks.
  • Atala ọnụ temometa ahụ.
  • Anwala ịkwasa temometa.
  • Store the thermometer out of reach of children.
  • Consult a physician for any health concerns. This device is for temperature measurement only and does not replace professional medical advice.

Ngwa ngwaahịa

The Physio Logic Accuflex 5VU Digital Thermometer package includes:

  • One (1) Accuflex 5VU Digital Thermometer
  • One (1) CR2032 battery (pre-installed)
  • Ntuziaka Ntuziaka Eserese
Physio Logic Accuflex 5VU Digital Thermometer Packaging

Image: Physio Logic Accuflex 5VU Digital Thermometer in its retail packaging. The packaging highlights features such as 'Accuflex 5VU', '5 Seconds', 'Color-coded fever alert', and 'BPA Free'.

Melite

Ntinye batrị

The thermometer comes with a CR2032 battery pre-installed. If the battery needs replacement, follow these steps:

  1. Locate the battery compartment cover on the back of the thermometer.
  2. Carefully open the cover.
  3. Remove the old battery and insert a new CR2032 battery with the positive (+) side facing up.
  4. Mechie mkpuchi batrị nke ọma.

Fahrenheit/Celsius Selection

Iji gbanwee n'etiti Fahrenheit (°F) na Celsius (°C):

  • With the thermometer turned off, press and hold the power button for approximately 3 seconds.
  • The display will show the current unit (°F or °C) and then switch to the other unit.
  • Release the button to confirm your selection. The thermometer is now ready for use in the selected unit.

Ọrụ

Ịgụ Ọgụgụ okpomọkụ

Ensure the thermometer is clean before use. Press the power button to turn on the device. The display will briefly show the last reading, then 'L' with a flashing '°F' or '°C', indicating it is ready for measurement.

  • Eji ọnụ Place the flexible tip under the tongue, as far back as comfortable. Close lips to hold the thermometer in place.
  • Axillary (Underarm) Use: Place the tip in the armpit, ensuring good skin contact. Hold the arm firmly against the body.
  • Eji Rectal: Apply a water-soluble lubricant to the tip. Gently insert the tip into the rectum (approximately 1/2 inch for infants/children, 1 inch for adults).

Hold the thermometer in position until a series of beeps indicates that the peak temperature has been reached (typically within 5 seconds for oral/rectal, longer for axillary).

Understanding Results

  • Ngosipụta Digital: The temperature reading will be shown on the large backlit screen.
  • Color Feverline Alert: The display features a color-coded indicator:
    • Green: Okpomọkụ nkịtị
    • Yellow: Mild fever
    • Red: High fever
  • Beep Indicator: A series of beeps signals that the measurement is complete.

Ncheta Ncheta

The thermometer automatically stores the last temperature reading. To view the last reading, press the power button briefly when the device is off. The stored temperature will be displayed for a few seconds before the thermometer enters measurement mode.

Gbanyụọ akpaaka

To conserve battery life, the thermometer will automatically turn off after approximately 10 minutes of inactivity.

Nlekọta na nlekọta

Nhicha

The thermometer is waterproof and washable. After each use, clean the thermometer tip with soap and cool water, or wipe with an alcohol swab. Do not immerse the entire thermometer in water for extended periods, and avoid harsh chemical cleaners.

Nchekwa

Store the thermometer in its protective case in a cool, dry place, away from direct sunlight and extreme temperatures.

Ngbanwe batrị

Refer to the 'Battery Installation' section under Setup for instructions on replacing the CR2032 battery.

Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Igwe ọkụ anaghị agbanwu.Batrị nwụrụ anwụ ma ọ bụ ntinye batrị na-ezighi ezi.Replace the battery (CR2032) or ensure it is inserted correctly.
Ọgụgụ na-ezighi ezi ma ọ bụ na-ekwekọghị ekwekọ.Improper placement, movement during measurement, or environmental factors.Ensure proper placement and stillness during measurement. Wait 15 minutes after eating, drinking, or exercising before taking an oral temperature.
Reading takes longer than 5 seconds.Axillary (underarm) measurements naturally take longer. Oral/rectal readings may vary slightly based on individual factors.Maintain proper placement until the beep indicates completion. The 5-second result is typical for oral/rectal use.
Ngosipụta na-egosi 'Lo' ma ọ bụ 'Hi'.Okpomọkụ dị n'èzí ebe enwere ike ịlele.Ensure the thermometer is at room temperature before use. If 'Lo' appears after measurement, it indicates a very low temperature.

Nkọwapụta

  • Ụdị: 016-651
  • Oke nha: 32.0°C – 42.9°C (89.6°F – 109.2°F)
  • izi ezi: ±0.1°C (±0.2°F) between 35.5°C – 42.0°C (95.9°F – 107.6°F)
  • Ngosipụta: Large Backlit LCD with Color Feverline Alert
  • Oge nledo: Approximately 5 seconds (oral/rectal)
  • Batrị: 1 x CR2032 (gụnyere)
  • Ndụ batrị: Approximately 200 hours of continuous operation
  • Akụkụ: 13.49 x 3.51 x 1.8 cm
  • Arọ: 18.14 g
  • Nchekwa onwe: Ihe dị ka nkeji iri
  • Nguzogide mmiri: Enwere ike ịsacha

Akwụkwọ ikike na nkwado ndị ahịa

The Physio Logic Accuflex 5VU Digital Thermometer comes with a Lifetime Warranty, ensuring quality and reliability. For warranty claims, technical assistance, or any questions regarding your product, please contact Physio Logic customer support. Refer to the product packaging or the official Physio Logic websaịtị maka ozi kọntaktị ugbu a.

Akwụkwọ ndị emetụtara - 016-651

Tupuview Ntuziaka onye ọrụ Physio Logic Accuflex Pro Digital Thermometer
Ntuziaka onye ọrụ zuru oke maka Physio Logic Accuflex Pro Digital Thermometer (Models 016-638, 016-639), atụmatụ mkpuchi, ntuziaka ojiji, ịkpachara anya, nhicha, nlekọta izugbe, nnọchi batrị, na nkọwapụta.
Tupuview Ntuziaka na ntuziaka onye ọrụ Physio Logic Accuflex Digital Thermometer
Ntuziaka onye ọrụ zuru oke maka Physio Logic Accuflex dijitalụ temometa. Mụta ka esi eji, hichaa, yana dozie temometa gị maka ọgụgụ okpomoku nke ọnụ, rectal na axillary ziri ezi. Gụnyere nkọwapụta ngwaahịa na ozi akwụkwọ ikike.
Tupuview Physio Logic DiGiPro Digital Clinical Thermometer User Guide
User guide for the Physio Logic DiGiPro Digital Clinical Thermometer (Model: 016-625), providing instructions for oral, rectal, and axillary temperature measurement, cleaning, care, and specifications.
Tupuview Akwụkwọ ntuziaka ntuziaka Physio Logic Insta-Therm Ear Thermometer
Akwụkwọ ntuziaka maka Physio Logic Insta-Therm temometa ntị na-agụ ngwa ngwa, njirimara mkpuchi, ọrụ, nnọchi batrị, nchọpụta nsogbu, na nkọwapụta.
Tupuview Ntuziaka onye ọrụ Physio Logic AccuflexPro+ Digital Thermometer
Ntuziaka onye ọrụ zuru oke maka Physio Logic AccuflexPro+ temometa dijitalụ, atụmatụ mkpuchi, ntuziaka ojiji maka ọnụ, rectal na axillary okpomọkụ, nhicha, nchọpụta nsogbu na nkọwapụta.
Tupuview Physio Logic Auto Inflate Ọbara Nyochaa: Akwụkwọ ntuziaka
Akwụkwọ ntuziaka zuru oke maka Physio Logic Auto Inflate Blood Pressure Monitor, atụmatụ mkpuchi, ojiji, nchọpụta nsogbu na nkọwapụta. Mụta ka esi elele ọbara mgbali elu gị n'ụlọ.