ESP UDTAKIT

ESP UDTAKIT 3 Part Disabled Toilet Alarm Nurse Call Kit User Manual

Model: UDTAKIT

1. Okwu mmalite

The ESP UDTAKIT is a comprehensive 3-part disabled toilet alarm and nurse call kit designed to provide an effective means for individuals in disabled access toilets to summon assistance in an emergency. This system is crucial for ensuring safety and compliance in public and commercial buildings. The kit comprises a pullcord unit, an illuminated LED indicator, and an alarm reset button, working together to alert staff when assistance is required.

ESP UDTAKIT 3 Part Disabled Toilet Alarm Nurse Call Kit packaging

Image 1.1: The ESP UDTAKIT packaging, showing the three main components: the pullcord unit, the illuminated LED unit, and the illuminated alarm reset button.

2. Ihe ngwugwu

Please ensure all components listed below are present and undamaged upon opening the package:

  • Pullcord Unit: Includes a red cuttable cord and handles, complete with a surface back box for mounting.
  • Illuminated LED Unit: Features an illuminated indicator, supplied with a surface back box.
  • Illuminated Alarm Reset Button: An illuminated button for alarm cancellation, provided with a surface back box.
  • Disabled Awareness Sticker: A self-adhesive sticker for placement on the toilet door to indicate the presence of the alarm system.

3. Ozi nchekwa

Before installation and operation, please read and understand the following safety guidelines:

  • Nchekwa Eletriki: Installation should only be performed by a qualified electrician in accordance with local wiring regulations and standards. Ensure the power supply is disconnected before commencing any wiring work.
  • Ịkwanye: Mount all units securely to a stable surface to prevent accidental dislodgement.
  • Ogologo eriri: The pullcord should be installed so that it is accessible from the floor, typically with one handle within reach of someone on the floor.
  • gburugburu: Do not install the system in areas with excessive moisture, extreme temperatures, or direct exposure to water, unless specifically rated for such environments.

4. Ntọala na nwụnye

Professional installation is highly recommended for this system to ensure correct functionality and compliance with safety standards. The system requires a suitable power supply (not included) to operate.

4.1. Component Placement

  • Pullcord Unit: Install inside the disabled toilet cubicle, typically near the toilet, at a height that allows the cord to reach the floor.
  • Illuminated LED Unit: Install outside the disabled toilet door, in a visible location, to provide a clear visual alert when the alarm is activated.
  • Illuminated Alarm Reset Button: Install inside the disabled toilet cubicle, near the door, at an accessible height for staff to reset the alarm.

4.2. Njikọ njikọ

The three units (Pullcord, LED, and Reset) are designed to be interconnected and connected to a suitable power source. While specific wiring diagrams are provided with the product packaging, the general principle involves:

  1. Connect the Pullcord Unit to the main alarm circuit.
  2. Connect the Illuminated LED Unit to the alarm circuit to receive activation signals.
  3. Connect the Illuminated Alarm Reset Button to the alarm circuit to allow for system reset.
  4. Connect the entire system to a stable and appropriate power supply.

Ensure all connections are secure and insulated. Test the system thoroughly after installation to confirm proper operation.

5. Ntuziaka ọrụ

5.1. Activating the Alarm

In an emergency, the user inside the disabled toilet can activate the alarm by pulling the red cord on the Pullcord Unit. This action will:

  • Trigger an audible alarm (approximately 80 dB) within the system.
  • Illuminate the LED on the Illuminated LED Unit outside the toilet, providing a visual alert.

5.2. Resetting the Alarm

Once assistance has been provided, the alarm can be reset by pressing the Illuminated Alarm Reset Button located inside the toilet cubicle. Pressing this button will:

  • Silence the audible alarm.
  • Turn off the illuminated LED on the external unit.

The system is then ready for subsequent use.

6. Nlekọta

Regular maintenance ensures the longevity and reliability of your ESP UDTAKIT.

  • Nhicha: Wipe the surface of all units with a soft, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
  • Nyochaa arụmọrụ: Periodically test the alarm system by pulling the cord to ensure the alarm sounds and the LED illuminates. Confirm the reset button functions correctly.
  • Nyocha eriri: Check the pullcord for any signs of wear or damage. Replace if necessary.
  • Njikọ: Ensure all wiring connections remain secure. If any issues are suspected, consult a qualified electrician.

7. Nchọpụta nsogbu

If you encounter issues with your ESP UDTAKIT, refer to the following common problems and solutions:

NsogbuIhe nwere ike imeNgwọta
Alarm does not sound when pullcord is activated.No power supply; loose wiring connection; faulty pullcord unit.Check power supply. Inspect all wiring connections. If problem persists, contact a qualified electrician or ESP support.
External LED does not illuminate.Loose wiring to LED unit; faulty LED unit.Check wiring to the LED unit. If problem persists, contact a qualified electrician or ESP support.
Alarm cannot be reset.Faulty reset button; wiring issue to reset button.Check wiring to the reset button. If problem persists, contact a qualified electrician or ESP support.
Alarm sounds intermittently.Loose connection; environmental interference.Inspect all wiring connections. Ensure the installation environment is stable.

For issues not listed here or if troubleshooting steps do not resolve the problem, please contact ESP customer support or a qualified electrician.

8. Nkọwapụta

  • Ụdị: UDTAKIT
  • Ụdị nkwụnye: Ugwu mgbidi
  • Teknụzụ sensọ: Sensọ kọntaktị
  • Usoro njikwa: Touch (for reset)
  • Ọkwa mkpọtụ: 80 dB
  • Isi mmalite ike: Requires external power supply (not included)
  • Akụkụ ngwugwu: 24.5 x 24 x 6 cm
  • Ibu ihe: 690 g
  • Agba: Red (pullcord)
  • Onye nrụpụta: ESP
  • Nke mbụ dị: Ọnwa Ise 30, 2017

9. Akwụkwọ ikike na nkwado

For information regarding product warranty, returns, or technical support, please refer to the documentation provided with your purchase or visit the official ESP websaịtị. A na-atụ aro ka ị debe ihe akaebe nke ịzụrụ ihe gị maka nkwupụta nkwa.

ESP Contact Information: Biko kpọtụrụ onye ọrụ nke onye nrụpụta ahụ website or product packaging for the most current contact details for customer service and technical support.

Akwụkwọ ndị emetụtara - UDTAKIT

Tupuview BS5839 Part 1: 2017 - A Guide to Fire Alarm Systems Design by ESP
This guide provides key insights into BS5839 Part 1: 2017, the code of practice for the design, installation, commissioning, and maintenance of fire detection and alarm systems in non-domestic premises. It offers essential guidance for designers and installers on selecting, spacing, and locating fire devices, covering system categories, detector types, coverage, positioning, cabling, and more.
Tupuview MAGPRO9601 Addressable Fire Alarm Panel: User Quick Guidelines
User quick guidelines for the ESP MAGPRO9601 Addressable Fire Alarm Panel, detailing how to review fault and warning events, handle fire alarms, perform zone testing, and disable system components.
Tupuview Ntuziaka ojiji ESP Prog v1.0 na Arduino IDE
Ntuziaka zuru oke maka iji ESP Prog v1.0 na Arduino IDE, gụnyere ntinye ọkwọ ụgbọala, ntọala ngwugwu bọọdụ, na mmemme ndị bụ isi.amples maka microcontrollers ESP8266.
Tupuview Ime ime View Ekwentị Ọnụ ụzọ: Ntuziaka maka ntinye na ọrụ
Nduzi zuru oke maka ntinye na ọrụ nke Remote View Ekwentị Ọnụ ụzọ (RVDP), nke na-ekpuchi ntọala, njikọta ngwa, atụmatụ, na nsogbu nsogbu.
Tupuview Duceri D1101SWH/SBK Emergency Twin Spot LED IP40 Lithium Batrị - Nduzi Ntinye na Mmezi
Ntuziaka zuru oke maka ntinye, ọrụ, na mmezi Duceri D1101SWH/SBK Emergency Twin Spot 6W LED IP40 luminaire. Nwere ọrụ nnwale onwe onye, ​​​​batrị lithium, na ozi gbasara nrubeisi.
Tupuview Banyeview Ọdụ Ọnụ Ụzọ VX nwere Ntinye na Ntuziaka Ọrụ nke Ọgụgụ Mkpisi Aka
Nduzi zuru oke maka ịwụnye, waya, mmemme, na nsogbu nsogbu ESP Enterview Ọdụ ọnụ ụzọ VX nwere ihe na-agụ mkpịsị aka agbakwunyere. Na-ekpuchi atụmatụ, ngwa ndị ọzọ dị mkpa, na ntọala sistemụ.