Okwu mmalite
This manual provides essential instructions for the safe and efficient use of your Techly Professional 023189 Vertical Rack Power Strip. Please read this manual thoroughly before installation and operation, and retain it for future reference.
The Techly Professional 023189 is a 12-outlet vertical rack-mountable power distribution unit (PDU) designed for professional environments. It features Schuko outlets, a thermal-magnetic circuit breaker for overload protection, and a durable aluminum and black finish.
Ozi nchekwa
WARNING: To reduce the risk of electric shock, fire, or injury, always follow basic safety precautions when using electrical products.
- Do not exceed the maximum load capacity of 3.5 kW (16 A, 250 V AC).
- Emebere ngwaahịa a maka naanị ime ụlọ.
- Do not connect multiple power strips together.
- Ensure the power strip is properly grounded.
- Do not open or modify the device. Refer all servicing to qualified personnel.
- Debe ya ebe mmiri na ebe mmiri dị elu na-anaghị eru.
- Ensure proper ventilation when installed in a rack.
Ihe ngwugwu
Verify that all items are present and undamaged:
- Techly Professional 023189 Vertical Rack Power Strip (12 Schuko outlets)
- Akwụkwọ ntuziaka onye ọrụ
Image: The product packaging box, labeled "TECHLY PROFESSIONAL 19" Power Distribution Unit".
Ngwaahịa gafereview
The Techly Professional 023189 is a robust power distribution unit designed for vertical mounting in 19-inch server racks. It provides 12 Schuko outlets for connecting various electrical devices.
Foto: Ihe zuru ezu view of the Techly Professional 023189 power strip, showing 12 Schuko outlets, the circuit breaker, and mounting brackets.
Akụkụ ndị bụ isi:
- 12 Schuko (IEC60884) outlets angled at 45°
- Integrated thermal-magnetic circuit breaker for overload protection
- Vertical rack-mountable design
- 3-meter power cable with angled Schuko plug
- Durable aluminum and black finish
- Maximum load capacity: 3.5 kW (16 A, 250 V AC)
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in an open position, revealing the blue switch and "I ON / O OFF" markings.
Foto: nkọwa zuru ezu view of the angled Schuko power plug, which connects the power strip to the main power source.
Ntọala na nwụnye
- Unpack the Power Strip: Carefully remove the power strip from its packaging. Inspect for any signs of damage.
- Họrọ Ebe Nkwanye: Select a suitable vertical location within a standard 19-inch server rack. Ensure there is adequate space for cable management and ventilation.
- Mount the Power Strip: Use appropriate rack screws (not included) to securely fasten the power strip's mounting brackets to the rack rails.
- Jikọọ na Isi Iyi: Plug the power strip's angled Schuko plug into a properly grounded wall outlet or UPS.
- Jikọọ Ngwaọrụ: Plug your electrical devices into the 12 Schuko outlets on the power strip. Ensure the total power consumption does not exceed 3.5 kW.
Image: A partial view of the power strip, highlighting the mounting brackets on the side, designed for vertical installation in a server rack.
Ọrụ
- Ike Na: Locate the thermal-magnetic circuit breaker on the power strip. Flip the switch to the "I ON" position to supply power to the outlets.
- Nchekwa ibu ibu: If the total current drawn by connected devices exceeds 16 A, the thermal-magnetic circuit breaker will automatically trip to the "O OFF" position, cutting power to prevent damage.
- Gbanyụọ: To cut power to all connected devices, flip the circuit breaker switch to the "O OFF" position.
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in a closed position, covering the blue switch.
Nlekọta
- Nhicha: Disconnect the power strip from the main power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- Nyocha: Periodically inspect the power strip, cable, and plug for any signs of wear, damage, or overheating. If any damage is observed, discontinue use immediately and replace the unit.
- Igwe ikuku: Ensure that the power strip and connected devices have adequate airflow to prevent overheating.
Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| No power to outlets. | Akwụsịla sekit sekit. | Reduce the load by unplugging some devices, then reset the circuit breaker by flipping it to "I ON". |
| No power to outlets. | Agbanyeghi eriri ọkụ. | Ensure the power strip's plug is securely inserted into a live wall outlet. |
| Devices not functioning. | Device-specific issue. | Check the individual device's power connection and functionality. |
Ọ bụrụ na nsogbu ahụ anọgide mgbe ị nwalechara ngwọta ndị a, kpọtụrụ ndị ọrụ nkwado ndị ahịa.
Nkọwapụta
- Ụdị: I-CASE STRIP-12SH
- Akara: Techly Professional
- Ụlọ ahịa: 12 x Schuko (Type F) 45° angled with earth
- Nkwụnye ntinye: Angled Schuko (Type F)
- USB: H05VV-F 3G 2.5 mm²
- Ogologo eriri USB: 3 mita
- Ọdụdọ Eletriki: 16 A, 250 V AC
- Oke ibu kacha: 3.5 kW
- Akụkụ (L x W x H): 735 x 62 x 44 mm (73.5L x 6.2W cm)
- Arọ: 1795 grams
- Ihe: Aluminum (body), Black (finish)
- Njirimara Pụrụ Iche: Mountable (vertical rack installation)
- Asambodo: CE, WEEE
Ozi akwụkwọ ikike
Information regarding specific warranty terms is not available in the provided product details. Please refer to the retailer's return policy or contact Techly Professional directly for warranty details.
Iwu nloghachi: The buybox winner indicates a 30-day return policy (refund/replacement).
Nkwado ndị ahịa
For technical assistance or further inquiries, please visit the official Techly websaịtị ma ọ bụ kpọtụrụ onye na-ere ahịa gị.
Onye nrụpụta: TECHLY PROFESSIONAL
Websaịtị: www.techly.com (Hypothetical link, as not provided in JSON)





