1. Okwu mmalite
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your EBARA Serie AGA 1.00 M Monophase Self-Priming Cast Iron Electric Pump. Please read this manual thoroughly before using the product and keep it for future reference. Adherence to these instructions will ensure optimal performance and extend the lifespan of your pump.
2. Ntuziaka nchekwa
Always observe the following safety precautions to prevent personal injury or damage to the pump.
- Nchekwa Eletriki: Ensure the pump is connected to a properly grounded electrical outlet. Do not operate the pump with damaged cables or plugs. Disconnect power before any maintenance or inspection.
- Nchekwa mmiri: Do not operate the pump dry. Ensure the pump is always submerged or primed with water before starting. Protect the pump from freezing temperatures.
- Nwụnye: Install the pump on a stable, level surface. Ensure adequate ventilation around the motor. All connections must be watertight.
- Ọrụ: Do not touch moving parts. Keep hands and clothing clear of the pump during operation.
- Nlekọta: Only qualified personnel should perform repairs. Use only genuine EBARA replacement parts.
3. Ngwaahịa gafereview
The EBARA Serie AGA 1.00 M is a robust monophase self-priming electric pump constructed from cast iron, designed for reliable water transfer applications. Its self-priming capability simplifies initial setup.
3.1 Atụmatụ
- Monophase electric pump
- Self-priming design
- Durable cast iron construction
- Suitable for various water transfer tasks
3.2 Foto ngwaahịa

Foto 1: Ihu ihu view of the EBARA Serie AGA 1.00 M electric pump. This image displays the pump's main body, motor housing, and electrical connection box, highlighting its robust blue cast iron construction.

Foto 2: Akụkụ view of the EBARA Serie AGA 1.00 M electric pump, illustrating its physical dimensions. The image shows the length (44cm), width (25cm), and height (21cm) of the pump, providing a clear understanding of its size for installation planning.
4. Nhazi
Ntinye kwesịrị ekwesị dị oke mkpa maka arụmọrụ nke ọkpọ mmiri ahụ na ogologo oge ya. Soro usoro ndị a nke ọma:
- Ịkwanye: Securely mount the pump on a firm, level, and vibration-free surface. Ensure it is protected from direct weather exposure if installed outdoors.
- Njikọ ọkpọkọ: Connect the suction and discharge pipes. Use appropriate fittings and ensure all connections are airtight to prevent air leaks, which can affect self-priming. The suction pipe should be as short and straight as possible.
- Njikọ eletrik: Connect the pump to a 220 Volt monophase power supply. Ensure the electrical circuit is protected by a suitable circuit breaker and residual current device (RCD). Wiring should be performed by a qualified electrician in accordance with local regulations.
- Priming (Initial Start-up): As this is a self-priming pump, it will automatically evacuate air from the suction line. However, for the very first start-up or after extended periods of disuse, it is recommended to fill the pump casing with water through the priming port (if available) to accelerate the priming process.
5. Ntuziaka ọrụ
Once installed and primed, operating the EBARA Serie AGA 1.00 M pump is straightforward:
- Ịmalite mgbapụta ahụ: Ensure all valves in the suction and discharge lines are open. Switch on the electrical power supply to the pump. The pump will start and begin to draw water.
- Nleba anya: Observe the pump during the first few minutes of operation. Check for any unusual noises, vibrations, or leaks. Ensure a steady flow of water is established.
- Ịkwụsị Mgbapụ: To stop the pump, simply switch off the electrical power supply. Close any necessary valves to prevent backflow or siphoning.
- Ojiji agbatịkwuru: For continuous operation, periodically check the pump's temperature and performance. Avoid running the pump dry, as this can cause severe damage.
6. Nlekọta
Regular maintenance ensures the longevity and efficiency of your EBARA pump.
- Nlele oge niile: Periodically inspect the pump for any signs of wear, corrosion, or leaks. Check electrical connections for tightness and integrity.
- Nhicha: Keep the exterior of the pump clean and free from debris. If the pump is used in dirty water applications, regularly check and clean the impeller and pump casing for blockages.
- Oge oyi: In areas prone to freezing temperatures, drain the pump completely and store it in a frost-free environment to prevent damage from ice expansion.
- Ndochi akara: If water leakage is observed from the shaft seal area, it may indicate a worn seal. This should be replaced by a qualified technician.
7. Nchọpụta nsogbu
This section addresses common issues you might encounter with your pump.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Mgbapụta anaghị ebido | No power supply; Motor overload; Faulty switch/wiring. | Check power connection and circuit breaker. Allow motor to cool if overloaded. Inspect wiring. |
| Pump runs but no water flow | Pump not primed; Air leak in suction line; Suction lift too high; Impeller clogged. | Ensure pump is primed. Check suction line for leaks. Verify suction lift is within specifications. Clean impeller. |
| Reduced water flow/pressure | Partial blockage in pipes/impeller; Worn impeller/diffuser; Air in system. | Inspect and clear blockages. Check for air leaks. Consider professional inspection for worn parts. |
| Oke mkpọtụ ma ọ bụ ịma jijiji | Cavitation (air in water); Loose mounting; Worn bearings; Foreign object in pump. | Check for air leaks in suction. Secure mounting. Inspect for foreign objects. Contact service for worn bearings. |
If you are unable to resolve an issue using this guide, please contact a qualified technician or EBARA customer support.
8. Nkọwapụta
Detailed technical specifications for the EBARA Serie AGA 1.00 M electric pump:
| Ụdị | Ebara |
| Nọmba nlereanya | 1100100000 |
| Akụkụ ngwaahịa (L x W x H) | 44 cm x 25 cm x 21 cm |
| Ibu ngwaahịa | 14.22 n'arọ |
| Ihe onwunwe | Cast Iron, Brass |
| Isi Iyi Ike | Igwe ọkụ eletrik |
| Voltage | 220 volts |
| Kachasị Elu Elu | 68 mita |
| Agba | Turquoise |
| Ụdị | Omuma |
9. Akwụkwọ ikike na nkwado
For warranty information, please refer to the documentation provided at the time of purchase or contact your authorized EBARA dealer. For technical support or service inquiries, please reach out to the manufacturer or your product supplier. Ensure you have your model number (AGA 1.00 M) and serial number (if applicable) ready when contacting support.
Manufacturer: Ebara