1. Okwu mmalite
This manual provides essential instructions for the safe installation, operation, and maintenance of your KING KB2407-1-B2-ECO ECO2S 7500W Garage Heater. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and adherence to these instructions are crucial for optimal performance and safety.
2. Ozi nchekwa dị mkpa
ỊDỌ AKA NA NTỊ: Ihe egwu nke ọkụ, ọkụ eletrik, ma ọ bụ mmerụ ahụ nye ndị mmadụ.
- Gụọ ntụziaka niile tupu ịwụnye ma ọ bụ jiri ikpo ọkụ a.
- Ihe na-ekpo ọkụ a na-ekpo ọkụ mgbe a na-eji ya. Iji zere ọkụ, ekwela ka akpụkpọ ahụ gba ọtọ metụ ebe ọkụ dị. Debe ihe ndị nwere ike ire ọkụ, dị ka arịa ụlọ, ohiri isi, ihe ndina, akwụkwọ, uwe, na ákwà mgbochi, ma ọ dịkarịa ala mita 0.9 site n'ihu ihe na-ekpo ọkụ ma debe ha ka ha ghara ịdị n'akụkụ na n'azụ.
- Kpachara anya dị oke mkpa mgbe ọkụ ọkụ ọ bụla na-eji ma ọ bụ nso ụmụaka ma ọ bụ ndị na-adịghị mma na mgbe ọ bụla a na-ahapụ ikpo ọkụ na-arụ ọrụ na n'enweghị nlekọta.
- Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped, or damaged in any manner. Discard heater or return to authorized service facility for examination and/or repair.
- Ejila n'èzí.
- Ebubeghi ikpo ọkụ a n'ime ụlọ ịsa ahụ, ebe a na-asa ákwà, na ebe ime ụlọ ndị yiri ya. Achọla ikpo ọkụ ebe ọ nwere ike ịdaba n'ime ebe ịsa ahụ ma ọ bụ akpa mmiri ọzọ.
- Ejila eriri n'okpuru kapeeti. Ejila akwa akwa, ndị na-agba ọsọ, ma ọ bụ ihe mkpuchi yiri ya kpuchie eriri. Hazie eriri pụọ na mpaghara okporo ụzọ yana ebe ọ na-agaghị akwụsị.
- Iji kwụpụ ikpo ọkụ, gbanyụọ njikwa, wee wepụ plọg na mpụta.
- Ejila ma ọ bụ kwe ka ihe ndị mba ọzọ banye n'ime ikuku ventilashị ma ọ bụ iyuzucha oghere n'ihi na nke a nwere ike ịkpata ujo eletrik ma ọ bụ ọkụ, ma ọ bụ mebie ikpo ọkụ.
- Iji gbochie ọkụ nwere ike ime, egbochila ikuku ma ọ bụ ikpochapụ n'ụzọ ọ bụla. Ejila n'elu dị nro, dịka akwa, ebe enwere ike igbochi oghere.
- Igwe ọkụ na-ekpo ọkụ nwere akụkụ na-ekpo ọkụ ma ọ bụ na-egbuke egbuke n'ime. Ejila ya na ebe a na-eji mmanụ ụgbọala, agba, ma ọ bụ vapors ma ọ bụ mmiri ọkụ na-ere ọkụ ma ọ bụ na-echekwa ya.
- Jiri kpo oku a naanị dị ka akọwara n'akwụkwọ ntuziaka a. Ojiji ọ bụla onye nrụpụta akwadoghị nwere ike ibute ọkụ, ujo eletrik ma ọ bụ mmerụ ahụ n'ime mmadụ.
- Na-atụnye ndị na-ekpo ọkụ mgbe ọ bụla n'ime ebe nchekwa mgbidi. Ejila eriri ndọtị ma ọ bụ mgbata ike mbugharị (oghere/oghere ọkụ).
- This heater is for 240V applications only.
3. Ihe ngwugwu
Verify that all components are present and undamaged. If any items are missing or damaged, contact your retailer.
- KING KB2407-1-B2-ECO ECO2S Garage Heater (7500W / 240V)
- Ihe nkwado maka Mgbidi zuru ụwa ọnụ/Ulo
- Njikwa anya
- Akwụkwọ ntuziaka (akwụkwọ a)

Image 3.1: The KING KB2407-1-B2-ECO ECO2S Garage Heater, showing the main unit, the universal mounting bracket, and the remote control.
4. Ntọala na nwụnye
A ga-arụrịrị nrụnye site n'aka onye ọrụ ọkụ eletrik ruru eru dịka koodu eletriki mpaghara na nke obodo siri dị.
4.1 Ebe nrịgo
- Select a location where the heater is protected from water spray, dripping water, and excessive dust.
- Ensure adequate clearance from combustible materials (minimum 3 feet from front, sides, and rear).
- Mount the heater securely to a structural member (stud, joist) capable of supporting its weight (approximately 33.5 lbs).
- The universal bracket allows for wall or ceiling mounting.
4.2 Ịkwanye Igwe ọkụ
- Attach the universal mounting bracket to a sturdy wall stud or ceiling joist using appropriate fasteners (not included). Ensure the bracket is level and securely fastened.
- Lift the heater and align the hanging hooks on top of the heater with the slots on the mounting bracket.
- Slide the heater onto the bracket until it is securely seated.
- Adjust the heater's angle as desired and secure it using the provided hardware to prevent accidental movement.
4.3 Igwe ọkụ eletrik
DANGER: Disconnect power at the main service panel before attempting any wiring to prevent electric shock.
- This heater requires a dedicated 240V circuit.
- The heater is rated for 7500W, drawing approximately 31.25 Amps. A circuit breaker and wiring sized appropriately for this load are required (e.g., 40 Amp breaker with 8-gauge wire, consult local codes).
- Access the internal wiring compartment by removing the appropriate cover plate on the heater.
- Connect the 240V supply wires to the heater's terminals as indicated in the wiring diagram inside the heater's compartment. Ensure proper grounding.
- Secure all wiring connections and replace the cover plate.

Foto 4.1: N'azụ view of the heater, illustrating the fan and location of electrical warning labels. Ensure all wiring is done by a qualified professional.
5. Ọrụ
Once properly installed and powered, the heater can be operated using its integrated control panel or the remote control.
5.1 Ogwe njikwa gafereview

Foto 5.1: N'ihu view of the heater, highlighting the digital display and control buttons for direct operation.
The control panel features a digital display and several buttons:
- Ngosipụta Digital: Shows current temperature, set temperature, and mode indicators.
- Bọtịnụ IKE: Turns the heater ON/OFF.
- Bọtịnụ MODE: Cycles through heating modes (ECO, HIGH, FAN ONLY).
- UP/DOWN Arrows: Adjusts the set temperature.
- Bọtịnụ TIMER: Activates or adjusts the timer function.
5.2 Ime Remote
The included remote control provides convenient access to all heater functions from a distance.
- Ensure batteries are correctly installed in the remote control.
- Point the remote control towards the heater's control panel for optimal signal reception.
- Buttons on the remote mirror the functions of the control panel (Power, Mode, Up/Down Temperature, Timer).
5.3 Ụdị arụ ọrụ
- Ọnọdụ ECO: The heater automatically selects the lowest wattage needed to maintain the set temperature, optimizing energy consumption.
- HIGH Heat Mode: The heater operates at full wattage (7500W) to quickly reach and maintain the set temperature.
- FAN ONLY Mode: The fan operates without engaging the heating elements, providing air circulation.
5.4 Ịtọ ntọala okpomọkụ
- Press the POWER button to turn the heater on.
- Use the UP or DOWN arrow buttons to set your desired temperature. The display will show the set temperature, then revert to the ambient temperature.
- The heater will automatically cycle on and off to maintain the set temperature.
5.5 Ọrụ ngụ oge
The timer allows you to set a duration for the heater to operate before automatically turning off.
- With the heater on, press the TIMER button.
- Use the UP or DOWN arrow buttons to set the desired operating time (e.g., 1-12 hours).
- The heater will operate for the set duration and then power off.
6. Nlekọta
WARNING: Always disconnect power to the heater at the main service panel before performing any maintenance or cleaning.
- Nhicha: Kwa oge na-ehicha mpụta nke ikpo ọkụ na nro, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
- Mwepụ uzuzu: Use a vacuum cleaner with a brush attachment to remove dust from the grilles and internal components. Ensure the fan blades are free of obstructions.
- Nyocha: Regularly inspect the power cord and plug for any signs of damage. If damage is found, discontinue use and contact a qualified electrician for repair.
- No lubrication is required for the motor.

Image 6.1: Close-up of the spiral steel heating elements. Regular cleaning helps maintain efficiency and prolong heater life.
7. Nchọpụta nsogbu
If your heater is not operating correctly, consult the following table before contacting customer support.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Igwe ọkụ anaghị agbanye. | Enweghị ọkụ. Akwụsịla sekit sekit. Nchekwa oke ọkụ agbanyere. | Ensure heater is properly wired and connected to 240V supply. Lelee ma tọgharịa ihe mgbawa sekit. Turn off heater, allow to cool for 30 minutes, then restart. Clear any obstructions. |
| Igwe na-ekpo ọkụ anaghị emepụta okpomọkụ zuru oke. | ahọpụtara ọnọdụ ezighi ezi. Tọọ okpomọkụ dị oke ala. Room size exceeds heating capacity. | Ensure HIGH or ECO mode is selected, not FAN ONLY. Dịkwuo okpomọkụ atọrọ. Verify the heater's coverage area (700 sq ft for 7500W) is appropriate for your space. |
| Fan runs but no heat. | FAN ONLY mode selected. Heating elements malfunction. | Switch to ECO or HIGH heat mode. If problem persists, contact a qualified technician. |
| Njikwa anya anaghị arụ ọrụ. | Batrị nwụrụ anwụ. Ihe mgbochi n'etiti ime ime na ikpo ọkụ. | Dochie batrị njikwa anya. Ensure a clear line of sight to the heater's control panel. |

Image 7.1: Heating coverage chart for various KING garage heater wattages. The 7500W model covers up to 750 sq ft.
8. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nlereanya | KB2407-1-B2-ECO |
| Ụdị | EZE |
| Wattage | 7500 Watt |
| Voltage | 240 volts |
| Ampoge | 31.25 Amps |
| Ihe mkpuchi kpo oku | Up to 700 ft² (based on 8 ft ceiling height and FHA standard insulation values) |
| Atụmatụ pụrụ iche | Remote Control, Built-In Fan Delay, Summer Fan Only & Timer Modes, ECO2S Electronic Thermostat |
| Ụdị nkwụnye | Universal Wall/Ceiling Bracket |
| Akụkụ ngwaahịa | 13.5 x 15 x 16.5 sentimita asatọ |
| Ibu Ibu | 33.5 pound |
| UPC | 093319220405 |
9. Akwụkwọ ikike na nkwado
For warranty information or technical support, please refer to the warranty card included with your product or visit the manufacturer's official websaịtị. Debe nnata nzụta gị dị ka ihe akaebe nke ịzụrụ maka nkwupụta ikike.
Onye Mmepụta: King Electric
For further assistance, contact King Electric customer service.