Baxtran IFN2001

Baxtran IFN 2001 Industrial Scale User Manual

Model: IFN2001

1. Okwu mmalite

This manual provides essential instructions for the proper installation, operation, and maintenance of your Baxtran IFN 2001 Industrial Scale. This robust platform scale is designed for industrial applications, offering a high capacity of 3000 kg with 1 kg accuracy. It features a durable steel frame, four load cells, and an external BR80 LED display. Please read this manual thoroughly before using the scale to ensure safe and efficient operation.

Baxtran IFN 2001 Industrial Scale with a cardboard box on its platform and the BR80 display unit next to it.

Foto 1: Baxtran IFN 2001 Industrial Scale with a package being weighed and the BR80 display unit.

2. Ozi nchekwa

3. Ihe ngwugwu

Nyochaa na akụrụngwa niile dị na adịghị emebi emebi mgbe ebupụ ya:

4. Nhazi

4.1 Mwepu na ntinye

Carefully remove all components from the packaging. Due to the scale's weight (approximately 202 kg / 445 lbs), it is recommended to use appropriate lifting equipment and personnel for safe handling and placement.

Place the scale platform on a firm, level, and stable surface. Ensure there is sufficient space around the scale for safe operation and to prevent any objects from touching the platform, which could affect accuracy.

Si elu gbadata view of the Baxtran IFN 2001 Industrial Scale platform, showing its textured surface.

Foto 2: The robust, textured surface of the Baxtran IFN 2001 scale platform.

4.2 Connecting the Display Unit

Connect the cable from the scale platform's junction box (Summenbox) to the designated port on the BR80 display unit. Ensure the connection is secure. The junction box is IP66 rated, providing protection against dust and powerful water jets.

4.3 Njikọ ike

Plug the AC/DC power adapter into the BR80 display unit and then into a suitable electrical outlet (100-240Vac, 50-60Hz). The display unit contains an internal 6V/4Ah battery, providing approximately 30 hours of operation on a full charge.

4.4 Ịkwalite Ọkwa

The scale is equipped with four height-adjustable feet (10 mm adjustment range). Use a spirit level to ensure the scale platform is perfectly level. Adjust each foot by rotating it until the scale is stable and level. This is crucial for accurate measurements.

Close-up of an adjustable foot on the Baxtran IFN 2001 Industrial Scale platform, showing the screw mechanism.

Foto 3: Detail of an adjustable foot on the scale platform, used for leveling.

4.5 Nhazi mbụ

The Baxtran IFN 2001 scale requires external calibration. This procedure should be performed by a qualified technician or according to local regulations using certified calibration weights. Refer to the BR80 display unit's specific manual for detailed calibration instructions, or contact your supplier for assistance.

5. Ntuziaka ọrụ

5.1 Gbanyụọ / gbanyụọ

Pịa Gbanye/ Gbanyụọ button on the BR80 display unit to power on the scale. The LED display will perform a self-test and then show "0.000 kg" when ready for use. Press the Gbanye/ Gbanyụọ button again to turn off the scale.

5.2 Ibu Ibu Dị Mkpa

  1. Ensure the display shows "0.000 kg" before placing any item on the platform.
  2. Carefully place the item to be weighed in the center of the scale platform.
  3. Wait for the reading on the BR80 LED display (20 mm digit size) to stabilize.
  4. Record the weight displayed in kilograms (kg).
  5. Remove the item from the platform. The display should return to "0.000 kg".

5.3 Tare arụ ọrụ

The tare function allows you to weigh items in a container by subtracting the container's weight.

  1. Place the empty container on the scale platform. The display will show its weight.
  2. Pịa NA-EGO button on the BR80 display unit. The display will reset to "0.000 kg".
  3. Place the items to be weighed inside the container. The display will now show only the net weight of the items.
  4. To clear the tare, remove both the container and items, then press the NA-EGO bọtịnụ ọzọ.

5.4 RS232 Output

The BR80 display unit is equipped with an RS232 output for connecting to a PC or printer. This allows for data transfer of weighing results. Refer to the BR80 display unit's specific manual for details on RS232 communication protocols and data formats.

5.5 Batrị arụ ọrụ

The internal 6V/4Ah battery provides up to 30 hours of continuous operation. When the battery level is low, a low battery indicator will appear on the display. Connect the scale to the AC/DC power adapter to recharge the battery. The scale can be operated while charging.

6. Nlekọta

6.1 Nhicha

Regularly clean the scale platform and display unit.

6.2 Nyocha

Nyochaa ihe ndị a kwa oge:

6.3 Nlekọta batrị

To prolong battery life, avoid fully discharging the battery frequently. Recharge the battery when the low battery indicator appears. If the scale is not used for an extended period, charge the battery periodically (e.g., every 3 months) to maintain its capacity.

7. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Ọkwa anaghị agbanye.No power from adapter; discharged battery; faulty power button.Check power adapter connection and outlet. Charge the battery. If problem persists, contact support.
Ọgụgụ na-ezighi ezi.Scale not level; external vibrations; damaged load cells; calibration required.Ensure scale is level. Relocate scale away from vibrations. Inspect load cells for damage. Perform external calibration.
Display shows "OVERLOAD" or error code.Weight exceeds maximum capacity; sudden impact.Remove excess weight. Avoid dropping items. If error persists, load cells may be damaged.
Ngosipụta bụ oghere ma ọ bụ na-egbuke egbuke.Loose cable connection; low battery; display unit fault.Check cable between platform and display. Charge battery. If problem persists, contact support.

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact your supplier or a qualified service technician.

8. Nkọwapụta

NlereanyaIFN 2001
Ike3000 n'arọ
Izi ezi1 n'arọ
Akụkụ Platform200 x 150 cm (205 x 154.99 cm product dimensions)
Frame IheỌkpụkpụ ígwè e ji agba agba
Ngwa PlatformPainted and lacquered steel with textured coating (black enameled)
Ibu Selụ4 x Nickel-plated steel, IP66 protection
Junction Box (Summenbox)ABS, nchekwa IP66
Ụkwụ na-agbanwe agbanwe4 x Height adjustable (10 mm)
Ngosipụta NkejiBR80 model, ABS casing
Ụdị ngosi7-segment LED, 20 mm digit size
Ngosipụta NchedoIP54
Batrị dị n'ime6V/4Ah, approx. 30 hours runtime
Okpomọkụ na-arụ ọrụ-10 Celsius C ruo 40 Celsius
Ịnye ọkụAC/DC adapter 100-240Vac 50-60Hz
NjikọtaRS232 output (for PC and printer)
Ibu ngwaahịa202 n'arọ (445.33 lbs)
Onye nrụpụtaGiropes

Akwụkwọ ndị emetụtara - IFN2001

Tupuview GLASSKS LCD Kitchen Scale User Manual - Features, Operation, and Care
Comprehensive user manual for the Baxtran GLASSKS LCD kitchen scale. Learn about features, installation, operation modes, weighing, tare function, cleaning, and maintenance. Includes model information and manufacturer details.
Tupuview Baxtran SS Series Digital Weighing Scale User Manual
Comprehensive user manual for the Baxtran SS Series digital weighing scale, covering setup, operation, features, maintenance, and calibration for models SS3, SS6, SS15, and SS30. Includes technical specifications, keyboard and display information, operation guides, parameter settings, and troubleshooting notes.
Tupuview Baxtran XTA/XTA-P Price Computing Scale User Manual
Comprehensive user manual for the Baxtran XTA and XTA-P price computing scales. Learn about features, operation, specifications, calibration, and troubleshooting for these accurate and reliable weighing instruments.
Tupuview STEELKS Kitchen Scale User Manual (EN/FR/DE)
Comprehensive user manual for the STEELKS kitchen scale, providing instructions in English, French, and German. Learn how to use its weighing, volume measurement, and unit conversion features.
Tupuview Baxtran BS-TRI ntuziaka onye ọrụ nha nha
Ntuziaka onye ọrụ maka usoro ihe ọ̀tụ̀tụ̀ nke Baxtran BS-TRI, na-akọwa nkọwapụta, nrụnye, ịrụ ọrụ, nhazi, nhazigharị, na koodu njehie maka nha nha na nha nhata.