Jebao DCP-2500

Jebao DCP-2500 Sine Wave Water Return Pump Instruction Manual

1. Okwu mmalite

This manual provides detailed instructions for the installation, operation, and maintenance of your Jebao DCP-2500 Sine Wave Water Return Pump. The DCP series pumps are designed for enhanced performance and precise flow control in aquarium systems, including reactors, sumps, or closed-loop setups. They feature a DCP Controller for adjustable flow, feed modes, and motor protection.

Jebao DCP-2500 Sine Wave Water Return Pump with controller and various fittings.

Figure 1: The complete Jebao DCP-2500 pump kit, including the main pump unit, the digital controller, the power adapter, and a selection of hose and PVC fittings for installation.

2. Ntuziaka nchekwa

Biko gụọ ma ghọta ntuziaka nchekwa niile tupu ị rụọ ọrụ mgbapụta ahụ. Ọdịda ịgbaso ntuziaka ndị a nwere ike ibute ujo ọkụ eletrik, ọkụ ma ọ bụ mmerụ ahụ dị egwu.

  • Internal Use Only: This pump is designed for internal use within an aquarium system. Do not use it for external applications.
  • Nchekwa Eletriki: Ensure the power outlet matches the pump's voltage (110-120V 60Hz). Always unplug the pump from the power source before performing any maintenance or cleaning.
  • kọntaktị mmiri: Never immerse the controller or power adapter in water. Ensure all electrical connections are dry.
  • No Copper Components: This pump is built without copper components, ensuring safety for your aquatic environment.
  • Nchedo eriri: Do not run the power cord over sharp edges or hot surfaces. Avoid kinking or damaging the cord.
  • Ụmụaka na anụ ụlọ: Keep the pump and its components out of reach of children and pets.

3. Ihe ngwugwu

Nyochaa na akụrụngwa niile dị na adịghị emebi emebi mgbe imepe ngwugwu:

  • DCP Pump Unit
  • Ihe nkwụnye AC
  • DCP Controller
  • Hose Fittings (1" and 3/4")
  • PVC Fittings (1-1/4")
  • O-rings and Gaskets

4. Nhazi

Follow these steps to properly install your Jebao DCP-2500 pump:

  1. Họrọ ebe: Place the pump in a stable position within your aquarium sump or designated water return area. Ensure it is fully submerged during operation.
  2. Attach Fittings: Select the appropriate hose or PVC fittings for your plumbing system. The pump supports 1" and 3/4" hose fittings, and 1-1/4" PVC fittings. Securely attach the chosen fittings to the pump's inlet and outlet.
  3. Jikọọ tubing: Connect your aquarium tubing to the pump's fittings. Ensure all connections are tight to prevent leaks.
  4. Njikọ njikọ: Plug the pump's cable into the DCP Controller. Then, connect the AC adapter to the controller and plug the adapter into a suitable electrical outlet.
  5. Mmalite Mbụ: Ensure the pump is fully submerged before powering on. The pump will self-prime once activated.
Agara nso view of the Jebao DCP-2500 Sine Wave Water Return Pump unit.

Ọgụgụ 2: A zuru ezu view of the Jebao DCP-2500 pump, highlighting its compact design and the protective intake grate.

5. Ntuziaka ọrụ

The DCP Controller allows for precise control over the pump's performance:

  • Gbanyụọ/ Gbanyụọ: Press the 'Power' button on the controller to turn the pump on or off.
  • Ndozi usoro: Use the '+' and '-' buttons to increase or decrease the water flow rate. The controller display will show the current power level.
  • Ụdị nri: Press the 'Feed' button to activate a 10-minute feed mode. The pump will pause for 10 minutes, allowing fish to feed without being disturbed by water flow. After 10 minutes, the pump will automatically resume its previous operation.
  • Ọrụ ebe nchekwa: The pump features a memory function that recalls the last set flow rate after a power outage.
  • Nchekwa moto: The controller includes motor protection that will shut down the pump if the rotor is blocked, preventing damage.

6. Nlekọta

Regular maintenance ensures optimal performance and longevity of your pump:

  • Ugboro nhicha: Clean the pump every 1-3 months, depending on the accumulation of debris in your aquarium.
  • Mbupu: Unplug the pump. Disconnect all tubing and carefully remove the pump from the sump. Twist and remove the intake grate and impeller cover.
  • Nhicha Impeller: Remove the impeller and clean it thoroughly with a soft brush under running water. Remove any calcium buildup or debris.
  • Nchacha ụlọ: Clean the pump housing and impeller chamber.
  • Nchikota: Reassemble the pump in reverse order, ensuring all parts are securely fitted.

7. Nchọpụta nsogbu

If you encounter issues with your pump, refer to the following common problems and solutions:

NsogbuIhe nwere ike imeNgwọta
Mgbapu anaghị amaliteNo power; blocked impeller; damaged controller/adapterCheck power connection; clean impeller; inspect controller/adapter for damage.
Mbelata ọsọ ọsọClogged impeller/intake; air in system; incorrect flow settingClean pump and intake; ensure pump is fully submerged and primed; adjust flow setting on controller.
Mkpọtụ/ama jijiji na-adịghị ahụkebeDebris in impeller; worn impeller; pump not stableClean impeller; inspect impeller for damage (replace if necessary); ensure pump is on a stable surface.
Mgbapụta ọkụ na-akwụsị obere ogeOverheating; motor protection activated (blocked rotor)Check for blockages and clean pump; ensure adequate water flow around pump for cooling.

8. Nkọwapụta

NjirimaraNkọwapụta
NlereanyaDCP-2500
Ike23 watt
Voltage110-120V 60Hz
Ọnụego nfe kacha660 GPH (Galọn 11 kwa nkeji)
Ogologo isi kachasị8.2 ụkwụ
Akụkụ ngwaahịa (L x W x H)6" x 5" x 4"
Hose Fitting Compatibility1" and 3/4"
PVC Fitting Compatibility1-1/4"
Ihe onwunwePVC
Ibu Ibu2 pound

9. Akwụkwọ ikike na nkwado

The Jebao DCP-2500 Sine Wave Water Return Pump comes with a Akwụkwọ ikike nke ụbọchị 180 site na ụbọchị ịzụrụ ya. Akwụkwọ ikike a na-ekpuchi ntụpọ nrụpụta n'oge ojiji nkịtị.

For technical support, warranty claims, or inquiries regarding your product, please contact your retailer or the manufacturer directly. Keep your proof of purchase for warranty validation.

Akwụkwọ ndị emetụtara - DCP-2500

Tupuview Akwụkwọ ntuziaka onye ọrụ Jebao DC Pump - Usoro DCP
Akwụkwọ ntuziaka onye ọrụ zuru oke maka Jebao DC Pumps (DCP-2500 ruo DCP-20000), na-ekpuchi atụmatụ, ọrụ, mmezi na nchọpụta nsogbu.
Tupuview Akwụkwọ ntuziaka onye nwe Pump Jebao DC - Ụdị DCP-2500 ruo DCP-20000
The Jebao DC Pump Owner's Manual provides comprehensive instructions for the safe operation, installation, maintenance, and troubleshooting of DCP-2500, DCP-3000, DCP-4000, DCP-5000, DCP-6500, DCP-8000, DCP-10000, DCP-15000, DCP-18000, and DCP-20000 models. Learn about features like adjustable flow rate, feed mode, memory function, and automatic power-off protection for both submersible and non-submersible applications in marine and fresh water environments.
Tupuview Akwụkwọ ntuziaka onye ọrụ Jebao Smart Wave - Ntọlite, arụmọrụ na nchọpụta nsogbu
Akwụkwọ ntuziaka onye ọrụ zuru oke maka Jebao Smart Wave Maker (MCP, MLW, MOW SERIES), na-ekpuchi nrụnye, njirimara, njikwa ngwa site na Jebao Aqua, ụdị ebili mmiri dị iche iche, nchọpụta nsogbu na mmezi. Mụta otu esi ahazi ma rụọ ọrụ onye na-eme ebili mmiri Jebao maka ọnọdụ akwarium kacha mma.
Tupuview Ntuziaka Onye Ọrụ nke Jebao MDC Series Aquarium Pumps
Akwụkwọ ntuziaka maka igwe eji eme ihe maka ọkpọkọ mmiri Jebao MDC, atụmatụ zuru ezu, ntuziaka nchekwa, ntinye, ọrụ, na nkọwapụta teknụzụ. Gụnyere ụdị MDC-2000 ruo MDC-10000.
Tupuview Akwụkwọ ntuziaka onye ọrụ Jebao Cross-Flow Wave Pump: CP-90, CP-120, CP-150
Akwụkwọ ntuziaka onye ọrụ maka mgbapụta Wave Jebao Cross-Flow, ụdị CP-90, CP-120, na CP-150. Gụnyere ntuziaka nchekwa, ntụzịaka mgbakọ, ọrụ njikwa, mmezi, na nkọwa nka.
Tupuview Jebao RF-B Series Automatic Feeder User Manual
Comprehensive user manual for the Jebao RF-B Series Automatic Feeder, detailing installation, operation, features, maintenance, and troubleshooting for aquarium fish feeding.