1. Okwu mmalite
The BFT Clonix 2E is a high-performance 2-channel radio receiver designed for use with BFT MITTO, KLEIO, and TRC remote control transmitters. Operating at 433.92 MHz, this receiver provides reliable wireless control for various automation systems, such as gates, garage doors, and barriers. It features a substantial memory capacity, capable of storing up to 128 remote controls, making it suitable for both residential and commercial applications.
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your Clonix 2E receiver. Please read this manual thoroughly before installation and keep it for future reference.

Figure 1: BFT Clonix 2E 2-channel receiver. This image shows the compact, grey housing of the receiver, designed for discreet installation.
2. Ozi nchekwa
Ntuziaka nchekwa dị mkpa:
- Kwụpụ ike mgbe niile tupu ị rụọ ọrụ nrụnye, mmezi, ma ọ bụ usoro nchọpụta nsogbu ọ bụla.
- Ndị ọrụ ruru eru ga-arụ ọrụ nrụnye ahụ dịka iwu na ụkpụrụ niile nke ọkụ eletrik dị n'ógbè ahụ siri dị.
- Do not expose the receiver to moisture, rain, or extreme temperatures.
- Gbaa mbọ hụ na ntọ ala kwesịrị ekwesị iji gbochie ujo eletrik.
- Use only BFT original spare parts and accessories.
- Keep packaging materials (plastic bags, polystyrene, etc.) out of reach of children, as they can be a source of danger.
3. Ihe ngwugwu
Hụ na ihe niile dị ma ghara imebi emebi mgbe ị meghere ngwugwu ahụ:
- BFT Clonix 2E 2-channel receiver unit
- Akwụkwọ ntuziaka
- Mounting screws (if included)
- Antenna wire (if external)

Figure 2: Package contents. This image displays the Clonix 2E receiver alongside its accompanying instruction manual, indicating typical items found in the product packaging.
4. Ntọala na nwụnye
The Clonix 2E receiver is designed for easy integration into existing or new automation systems. Follow these steps for proper installation:
4.1 Ịwụnye ihe nnata ahụ
- Choose a suitable location for mounting the receiver. It should be protected from direct weather exposure and easily accessible for wiring.
- Secure the receiver to a flat, stable surface using appropriate screws.
4.2 Njikọ njikọ
Refer to the internal wiring diagram for correct connections. The Clonix 2E operates on 12-24V AC/DC power.

Figure 3: Internal components and wiring terminals. This image provides a view inside the Clonix 2E receiver, highlighting the terminal block for electrical connections and the antenna wire.
- Ịnye ọkụ: Connect the 12-24V AC/DC power supply to the designated terminals (usually marked + and - or AC/DC).
- Ọwa mmepụta: Connect the two output channels to your automation system's control inputs. These are typically dry contact relays.
- Antenna: Connect the antenna wire to the antenna terminal for optimal range. Ensure the antenna is extended and positioned for best signal reception.
4.3 Programming Remote Controls
The Clonix 2E can store up to 128 remote controls. The programming procedure typically involves pressing a button on the receiver and then activating the remote control.
- Locate the programming button on the receiver's circuit board (often labeled "PROG" or "MEM").
- Press and hold the programming button until an indicator LED (if present) illuminates or flashes.
- While the LED is active, press the button on your remote control that you wish to program.
- The LED should change state (e.g., flash rapidly, turn solid, or turn off) to indicate successful programming.
- Repeat for additional remote controls or buttons as needed.
- To clear all programmed remotes, consult the specific instructions provided with your receiver, as this often involves holding the programming button for an extended period.
5. Ntuziaka ọrụ
Once installed and programmed, operating the Clonix 2E receiver is straightforward:
- Ensure the receiver is powered on and correctly connected to your automation system.
- Use a programmed BFT MITTO, KLEIO, or TRC remote control.
- Press the desired button on the remote control. The receiver will activate the corresponding output channel, triggering the connected device (e.g., opening/closing a gate).
- The maximum operating range is approximately 200 meters, though this can vary based on environmental factors and obstacles.
6. Nlekọta
The BFT Clonix 2E receiver requires minimal maintenance to ensure long-term reliable operation:
- Nhicha: Periodically clean the exterior of the receiver with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Njikọ: Kwa afọ, lelee njikọ waya niile iji hụ na ha dị nchebe ma ghara imebi emebi.
- Antenna: Hụ na antenna ahụ emebighị ma ọ dịkwa n'ọnọdụ ya nke ọma maka nnata mgbaàmà.
- Nchekwa gburugburu: Verify that the receiver remains protected from moisture and extreme temperatures.
7. Nchọpụta nsogbu
If you experience issues with your Clonix 2E receiver, consult the following table:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Onye nnata anaghị aza ihe na remote. | Enweghị ike ịnata. Remote control battery is low/dead. Remote not programmed. Enweghị oke. | Lelee njikọ ọkọnọ ike. Dochie batrị njikwa anya. Reprogram the remote control (see Section 4.3). Gaa nso na onye na-anata ihe. |
| Mbelata oke ọrụ. | Antenna obstructed or damaged. Mmanya sitere na ngwaọrụ ndị ọzọ. Receiver mounted in a metal enclosure. | Check antenna connection and position. Ensure it is extended. Identify and mitigate sources of interference. Relocate receiver or use an external antenna. |
| Receiver LED not illuminating. | Enweghị ike. Ngalaba na-adịghị mma. | Nyochaa ọkọnọ ike. Contact BFT support or a qualified technician. |
8. Nkọwapụta
Technical specifications for the BFT Clonix 2E 2-channel receiver:
| Njirimara | Nkọwa |
|---|---|
| Nọmba nlereanya | OR-511 |
| Ugboro ugboro | 433.92 MHz |
| Ọwa | 2 |
| Ịnye ọkụ | 12-24V AC / DC |
| Ike ebe nchekwa | 128 remote njikwa |
| Oke kacha | 200 Meters (line of sight) |
| Akụkụ (L x W x H) | 6.81 x 3.82 x 1.93 sentimita asatọ |
| Ibu Ibu | 5.6 ounces |
| ASIN | B01MXR9SNO |

Figure 4: Product label with specifications. This image provides a detailed view of the Clonix 2E's label, confirming its model type, operating frequency, and power requirements.
9. Akwụkwọ ikike na nkwado
BFT products are manufactured to high-quality standards. For warranty information, please refer to the warranty card included with your product or visit the official BFT websaịtị. Debe ihe akaebe nke ịzụrụ maka akwụkwọ ikike.
For technical support, troubleshooting assistance beyond this manual, or to inquire about spare parts, please contact BFT customer service or your authorized BFT dealer. Contact information can typically be found on the BFT official websaịtị ma ọ bụ na nkwakọ ngwaahịa.
BFT Official Websaịtị: www.bftautomation.com