1. Ngwaahịa gafereview
The Star S1104 0.3 HP Drain Pump System is an automatic, compact solution designed for efficient wastewater removal from various fixtures such as wet bars, sinks, water softeners, and laundry trays. Its innovative non-clog vortex impeller ensures smooth drainage without the need for frequent cleaning or filter replacement. This system is engineered for easy installation, requiring no roughed-in plumbing, making it a versatile choice for many applications.

Figure 1.1: Star S1104 Drain Pump System components.
2. Ozi nchekwa
Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.
- Always disconnect power before servicing the pump system.
- Gbaa mbọ hụ na ntọ ala kwesịrị ekwesị iji gbochie ihe egwu eletrik.
- Ejila eriri ma ọ bụ plọg mebiri emebi arụ ọrụ mgbapụta ahụ.
- Ngwaahịa a nwere kemịkalụ mara steeti California ka ọ na-ebute ọrịa kansa na ntụpọ ọmụmụ ma ọ bụ mmerụ ahụ ọmụmụ ọzọ. Saa aka ma emechaa.
- Ọ bụrụ na ị maghị ihe ị ga-eme, ọkachamara ruru eru kwesịrị ịrụ ọrụ nrụnye ahụ.
3. Ihe ngwugwu
Hụ na ihe niile dị ma ghara imebi emebi mgbe ị meghere ngwugwu ahụ:
- Star S1104 Drain Pump
- Collection Basin na mkpuchi
- Integrated Vertical Float Switch
- 1 1/2-inch NPT Discharge Hose Adapter
- Assorted Hardware (washers, nuts, bolts)
- Inlet and Vent Connections
4. Nkọwapụta
| Njirimara | Nkọwapụta |
|---|---|
| Ụdị | Kpakpando |
| Nọmba nlereanya | S1104 |
| Ike inyinya | 0.3 HP |
| Voltage | 115 volts |
| Isi Iyi Ike | AC/DC |
| Ọnụego nfe kacha | galọn 43 kwa nkeji (GPM) |
| Ihe onwunwe | Igwe anaghị agba nchara, Plastic |
| Ibu Ibu | 23 pound |
| Discharge Hose Size | 1 1/2-inch NPT |
| Akụkụ (Ihe dị ka) | 14.4 x 14.7 x 14.7 sentimita asatọ |
5. Ntọala na nwụnye
The Star S1104 Drain Pump System is designed for straightforward installation in various settings, including wet bars, utility sinks, and water softeners. It does not require complex roughed-in plumbing, simplifying the setup process.
5.1 Ebe nwụnye
This versatile system can be installed in:
- Wet Bars
- Kitchen Sinks (where gravity drainage is not feasible)
- Water Softener Discharge
- Laundry Trays/Sinks

Figure 5.1: Versatile installation options for the S1104 system.
5.2 General Installation Steps (Consult local plumbing codes)
- Ndokwa: Place the collection basin in a stable, level location, typically beneath the sink or fixture it will serve. Ensure adequate space for connections and future access.
- Njikọ Ntinye: Connect the drain line from your sink or fixture to the inlet port on the basin. Use appropriate plumbing fittings and sealants to ensure a watertight connection.
- Discharge Line: Connect a 1 1/2-inch NPT discharge pipe to the pump's outlet. Route this pipe to a suitable drain or sewer connection, ensuring it has an upward slope to prevent backflow.
- Vent Line: Connect a vent line to the basin's vent port. This line should extend to an open air vent or tie into an existing vent stack according to local codes.
- Njikọ eletrik: Plug the pump into a properly grounded 115-volt electrical outlet. Ensure the circuit is protected by a Ground Fault Circuit Interrupter (GFCI).
- Nnwale: Once all connections are secure, fill the sink or fixture with water to test the pump's operation. The pump should activate when the water level rises and shut off when it falls.
Vidiyo 5.1: Agafeeview of the Drain Maker Sink Pump System and its easy installation.
6. Ọrụ
The Star S1104 Drain Pump System operates automatically, providing hassle-free wastewater removal.
6.1 Ọrụ akpaaka
The system is equipped with a vertical float switch. When the water level in the collection basin rises to a predetermined point, the float switch activates the pump. The pump then rapidly drains the water through the discharge hose. Once the water level drops below the activation point, the float switch deactivates the pump.
6.2 Non-Clog Vortex Impeller
The pump features a non-clog vortex impeller. This design creates a whirlpool effect that efficiently moves water and small solids without clogging, eliminating the need for internal filters or screens that require regular cleaning or replacement.

Figure 6.1: The non-clogging vortex impeller ensures efficient drainage.
7. Nlekọta
The Star S1104 Drain Pump System is designed for minimal maintenance due to its non-clogging impeller and automatic operation. However, periodic checks are recommended to ensure optimal performance.
- Nyocha oge niile: Periodically inspect the basin for any debris accumulation. While the impeller is designed to handle small solids, large foreign objects could impede operation.
- Float Switch Check: Ensure the float switch moves freely and is not obstructed by any buildup or debris within the basin.
- Iguzosi ike n'ezi ihe njikọ: Check all plumbing and electrical connections for leaks or signs of wear. Tighten any loose connections.
- Nhicha: If necessary, the interior of the basin can be cleaned with mild soap and water after disconnecting power and removing the pump.
8. Nchọpụta nsogbu
Lee tebụl na-esonụ maka nsogbu ndị a na-enwekarị na ngwọta ha nwere ike inye:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Mgbapụta ọkụ anaghị agbanwu | No power; Float switch stuck; Clogged impeller | Check power supply/GFCI; Clear float switch path; Inspect impeller for obstructions (disconnect power first) |
| Mgbapụta ọkụ na-aga n'ihu | Float switch stuck in ON position; Backflow in discharge line | Clear float switch path; Check for proper check valve operation in discharge line |
| Low flow or no water pumped | Partial clog in discharge line or impeller; Air lock; Insufficient water in basin | Clear clogs; Bleed air from system; Ensure adequate water level for pump activation |
| Oke mkpọtụ ma ọ bụ ịma jijiji | Debris in impeller; Loose mounting; Air in system | Inspect and clear impeller; Secure pump mounting; Check for air leaks in inlet |
Ọ bụrụ na usoro nchọpụta nsogbu anaghị edozi nsogbu ahụ, kpọtụrụ nkwado ndị ahịa.
9. Akwụkwọ ikike na nkwado
The Star S1104 Drain Pump System comes with a Akwụkwọ ikike dị afọ 1 from the date of purchase, covering defects in materials and workmanship under normal use and service.
For technical assistance, warranty claims, or to purchase replacement parts, please visit the official Star Water Systems websaịtị ma ọ bụ kpọtụrụ ngalaba ọrụ ndị ahịa ha.
Ndị ọchịchị Websaịtị: www.starwatersystems.com