BRESSA 7000020CM3000

BRESSER Temeo Quadro Temperature Station User Manual

Ụdị: 7000020CM3000

Okwu mmalite

The BRESSER Temeo Quadro Temperature Station is designed to monitor temperature and humidity at up to four different locations simultaneously. This system includes a main display unit and three remote sensors, allowing you to track environmental conditions both indoors and outdoors, or in various rooms of your home. The remote sensors transmit data wirelessly to the main unit via a 433 MHz radio signal.

Ozi nchekwa

  • Gụọ ntuziaka niile nke ọma tupu i jiri ngwaọrụ ahụ.
  • Debe akwụkwọ ntuziaka a maka ntụnye aka n'ọdịnihu.
  • Ewepụla ngwaọrụ ahụ na oke okpomọkụ, ìhè anyanwụ kpọmkwem, ma ọ bụ oke iru mmiri.
  • Zere idobe ma ọ bụ idobe ngwaọrụ ahụ na mmetụta siri ike.
  • Anwala ịkwasa ma ọ bụ rụkwaa ngwaọrụ n'onwe gị. Kpọtụrụ ndị ọrụ ruru eru.
  • Tụfuo batrị eji arụ ọrụ dịka iwu obodo siri dị.

Ihe ngwugwu

  • 1x BRESSER Temeo Quadro Main Display Unit
  • 3x Remote Sensors
  • 1 x Akwụkwọ ntuziaka onye ọrụ (akwụkwọ a)

Note: Batteries are not included. The main unit requires 3x AAA (LR03) batteries, and each remote sensor requires 2x AAA (LR03) batteries.

Ngwaahịa gafereview

Ngalaba ngosi isi

N'ihu view of the BRESSER Temeo Quadro main unit display.

Foto: N'ihu view of the BRESSER Temeo Quadro main unit display. A clear view of the main unit's LCD screen, showing temperature and humidity values for four channels.

N'azụ view of the BRESSER Temeo Quadro main unit, showing control buttons and battery compartment.

Foto: N'azụ view of the BRESSER Temeo Quadro main unit, showing control buttons and battery compartment. The back of the main unit includes buttons for 'CHANNEL', 'ALARM', 'MAX/MIN', and 'SET', along with the battery compartment cover.

  • Ngosipụta LCD: Shows temperature and humidity for the main unit (IN) and up to three remote sensors (1, 2, 3).
  • CHANNEL Button: Selects which remote sensor's data is displayed or cycles through channels.
  • Bọtịnụ Mkpuchi: Activates/deactivates temperature/humidity alarms.
  • Bọtịnụ MAX/MIN: Na-egosi uru kachasị na nke kacha nta e dekọrọ.
  • Bọtịnụ SET: Enters setup mode for time, date, and alarm settings.
  • Akụkụ batrị: Located on the rear, for 3x AAA batteries.
  • Nguzosi Ike Ejikọtara: For desktop placement.

Ihe mmetụta dị anya

BRESSER Temeo Quadro remote sensor, front and back views.

Foto: BRESSER Temeo Quadro remote sensor, front and back views. A remote sensor unit, showing its display on the front and the battery compartment and mounting hole on the back.

  • Ngosipụta LCD: Shows its current temperature and humidity.
  • Mgbanwe ọwa: Allows selection of channel 1, 2, or 3.
  • Akụkụ batrị: For 2x AAA batteries.
  • Oghere Nkwanye: Maka ịgbanye mgbidi.

Melite

1. Ntinye batrị

  1. For Remote Sensors:
    • Mepee mkpuchi nke batrị dị n'azụ ihe mmetụta ọ bụla dị n'ime ime obodo.
    • Insert 2x AAA (LR03) batteries into each sensor, observing the correct polarity (+/-).
    • Set the channel switch (1, 2, or 3) on each sensor to a unique channel.
    • Mechie mkpuchi oghere batrị.
  2. For Main Display Unit:
    • Mepee mkpuchi nke batrị dị n'azụ nke isi ngwaọrụ ahụ.
    • Insert 3x AAA (LR03) batteries, observing the correct polarity (+/-).
    • Close the battery compartment cover. The main unit will power on and begin searching for sensor signals.

2. Sensor Pairing

  • After installing batteries in both the sensors and the main unit, the main unit will automatically attempt to connect with the remote sensors.
  • Ensure the remote sensors are within range (typically up to 30 meters in open air) of the main unit during initial setup.
  • The corresponding channel numbers (1, 2, 3) on the main unit's display will show readings once a connection is established. The 'IN' channel displays the main unit's internal readings.
  • If a sensor does not connect, remove and reinsert its batteries, then press the 'CHANNEL' button on the main unit to initiate a new search.

3. Ntinye

  • Place the main unit indoors in a central location, away from direct sunlight or heat sources.
  • Position remote sensors in desired monitoring areas. For outdoor use, place sensors in a sheltered spot to protect them from direct rain and sun, which can affect accuracy and device longevity.

Ntuziaka ọrụ

Viewing Okpomọkụ na iru mmiri

  • The main display unit continuously shows the current temperature and humidity for the internal sensor ('IN') and the three remote sensors (1, 2, 3).
  • The display also indicates comfort levels (e.g., 'COM' for comfortable, 'DRY' for dry, 'WET' for wet) based on humidity levels.

Ndekọ MAX/MIN

  • Pịa MAX/MIN button once to display the maximum temperature and humidity recorded since the last reset.
  • Pịa MAX/MIN button a second time to display the minimum temperature and humidity recorded.
  • To clear the MAX/MIN records, press and hold the MAX/MIN button for approximately 3 seconds while MAX or MIN values are displayed.

Nhọrọ nkeji okpomọkụ (°C/°F)

  • On the main unit, press the SET button to toggle between Celsius (°C) and Fahrenheit (°F).

Setting Alarms (if applicable)

  • Pịa Mkpu bọtịnụ iji tinye ọnọdụ ntọala mkpu.
  • Jiri ihe CHANNEL na MAX/MIN buttons to adjust the desired high and low temperature/humidity alarm thresholds for each channel.
  • Pịa Mkpu again to confirm settings and activate the alarm. An alarm icon will appear on the display.
  • When an alarm threshold is met, the unit will emit an audible alert and the corresponding channel's reading will flash.

Nlekọta

  • Nhicha: Jiri nwayọ hichaa ngwaọrụ ahụ, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
  • Ngbanwe batrị: Replace batteries when the low battery indicator appears on the display. Always replace all batteries in a unit at the same time.
  • Nchekwa: Ọ bụrụ na ị na-echekwa ngwaọrụ ahụ ruo ogologo oge, wepụ batrị niile iji gbochie mmiri ịpụ apụ.

Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Enweghị ngosipụta na isi ngwaọrụ.Batrị anwụọla ma ọ bụ tinye na ezighi ezi.Lelee polarity batrị ma jiri batrị AAA ọhụrụ dochie ya.
Remote sensor not displaying data on main unit.Sensor out of range, incorrect channel setting, or dead batteries.
  • Bugharịa ihe mmetụta ahụ nso na isi ngwaọrụ ahụ.
  • Ensure sensor channel switch matches the desired channel on the main unit.
  • Dochie batrị sensọ.
  • Press the 'CHANNEL' button on the main unit to re-scan for sensors.
Ọgụgụ na-ezighi ezi.Ihe mmetụta e tinyere n'anwụ kpọmkwem, ebe okpomọkụ, ma ọ bụ mmiri mmiri.Relocate sensors to a more appropriate, sheltered environment. Allow time for readings to stabilize.
Intermittent signal loss.Interference from other electronic devices or physical obstructions.Move the main unit or sensors away from potential sources of interference (e.g., TVs, microwaves, large metal objects).

Nkọwapụta

Nọmba nlereanya7000020CM3000
ỤdịBRESSER
Nha Ngwaahịa (Isi ihe)1.02 x 4.13 x 4.72 sentimita (2.59 x 10.49 x 11.99 cm)
Item Weight (Main Unit)0.19 Kilogram (ihe dị ka 6.7 ounces)
Temperature Range (Main Unit)Internal sensor range not specified, but upper rating is 55 °C.
Okpomọkụ ziri ezi±1 Celsius C
Oke iru mmiriNot specified, but typically 20% to 95% for similar devices.
Ugboro ikuku433 MHz
Isi Iyi Ike (Isi ngalaba)3x AAA (LR03) batteries
Power Source (Remote Sensor)2x AAA (LR03) batteries per sensor
Number of Remote Sensors Supported3

Akwụkwọ ikike

This BRESSER product comes with a akwụkwọ ikike afọ abụọ against factory defects from the date of purchase. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by improper use, accidents, unauthorized repairs, or normal wear and tear.

Nkwado

For technical support, warranty claims, or further information, please visit the official BRESSER website or contact their customer service department. Refer to the packaging or the BRESSER websaịtị maka nkọwa kọntaktị kachasị ugbu a.

Online resources may include FAQs, additional manuals, and contact forms.

Akwụkwọ ndị emetụtara - 7000020CM3000

Tupuview Bresser ClimaTrend Hygro Quadro Digital Thermo-Hygrometer User Manual
Comprehensive instruction manual for the Bresser ClimaTrend Hygro Quadro digital thermo-hygrometer, detailing setup, operation, alarm functions, and specifications. Includes model numbers 7000020CM3000, 7000020GYE000, 7000020QT5000.
Tupuview Bresser ClimaTrend Hygro Quadro Wireless Weather Station Instruction Manual
Comprehensive instruction manual for the Bresser ClimaTrend Hygro Quadro wireless weather station, covering setup, operation, features, alarm settings, comfort level, declarations, maintenance, warranty, and contact information.
Tupuview BRESSER Thermo-/Hygrometer Quadro mit 3 Außensensoren Bedienungsanleitung
Umfassende Bedienungsanleitung für das BRESSER Thermo-/Hygrometer Quadro. Erfahren Sie mehr über Einrichtung, Bedienung, Funktionen und Wartung für präzise Innen- und Außentemperatur- und Luftfeuchtigkeitsmessungen.
Tupuview Bresser ClimaTrend Hygro Quadro Ntuziaka ntuziaka
Nduzi zuru oke maka ọdụ ihu igwe Bresser ClimaTrend Hygro Quadro, nhazi zuru ezu, ọrụ, atụmatụ dị ka nlekota ọtụtụ sensọ, usoro okpomọkụ, ọkwa nkasi obi, na mkpu maka ụdị 7000020CM3000, 7000020GYE000, 7000020QT5000.
Tupuview BRESSER Temeo Life Wetterstation Bedienungsanleitung
Umfassende Bedienungsanleitung für die BRESSER Temeo Life Wetterstation. Erfahren Sie mehr über Installation, Funktionen, technische Daten und Sicherheitshinweise.
Tupuview Ntuziaka ntuziaka maka ojiji nke BRESSER Quadro NV Thermo-Hygrometer
Akwụkwọ ntuziaka zuru oke maka BRESSER Quadro NV Thermo-Hygrometer, nke na-ekpuchi ntọala, atụmatụ, nkọwapụta teknụzụ, na ozi nchekwa n'ọtụtụ asụsụ.