The Fluke 15B+ Digital Multimeter is a rugged, reliable, and accurate tool designed for various electrical applications. It offers essential measurement capabilities in a user-friendly design, suitable for both professional and serious DIY users.

Foto: N'ihu view of the Fluke 15B+ Digital Multimeter, showing the display, rotary dial, and input jacks.
Akụkụ ndị bụ isi:
- Ntụle nchekwa CAT III 600V: Ensures safety for electrical systems in residential and commercial settings.
- AC/DC Voltage Measurement up to 1000V: Na-atụ ma AC na DC voltage for a wide range of applications.
- AC/DC Current Measurement up to 10A: Accurately measures AC and DC current for diagnosing electrical issues.
- Ọrụ Nleta Ọtụtụ: Na-agụnye Voltage, Resistance, Continuity, Diode, and Capacitance.
- Input Terminal for AC/DC Current Measurements: Dedicated input for current measurements up to 10A.
2. Ozi nchekwa
Always adhere to safety precautions when using any electrical testing equipment. Failure to do so may result in injury or damage to the meter or equipment under test.
- Gụọ ntuziaka: Read and understand all instructions and safety information before use.
- Ojiji nke ọma: Use the multimeter only as specified in this manual; otherwise, the protection provided by the multimeter might be impaired.
- Ogo Voltage: Etinyekwala ihe karịrị ogo voltage, as marked on the multimeter, between the terminals or between any terminal and earth ground.
- Inspect Leads: Inspect test leads for damaged insulation or exposed metal. Replace damaged leads.
- Avoid Live Circuits: Do not use the multimeter on live circuits with exposed conductors or bus bars.
- Ngwa nchekwa nkeonwe (PPE): Always wear appropriate personal protective equipment, such as safety glasses and insulated gloves, when working with electrical systems.
- CAT III 600V: This meter is rated for CAT III 600V. Do not use it in environments exceeding this rating.
3. Kedu ihe dị na Igbe ahụ
Your Fluke 15B+ Digital Multimeter package includes the following items:
- Fluke 15B+ Digital Multimeter
- TL75 Test Leads
- Batrị AA 2 (etinyere ya ma ọ bụ tinye ya iche)

Image: The Fluke 15B+ Digital Multimeter shown alongside its red and black TL75 test leads and protective caps.
4. Nhazi
4.1 Ntinye batrị
The Fluke 15B+ requires two AA batteries for operation. These are typically included with your purchase.
- Hụ na agbanyụrụla multimeter ahụ.
- Chọta mkpuchi nke ebe batrị ahụ n'azụ multimeter ahụ.
- Jiri skrudị mee ka skru ahụ dị jụụ nke na-ejide mkpuchi ahụ.
- Remove the cover and insert the two AA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Replace the battery compartment cover and tighten the screw(s).
4.2 Njikọ Ndị Nnwale Nlele
Proper connection of test leads is crucial for accurate and safe measurements.
- Fanye ya nwa ule ndu n'ime COM (nkịtị) ntinye.
- Maka ọtụtụ voltage, resistance, continuity, diode, and capacitance measurements, insert the uhie ule ndu n'ime VΩHzCAP jakị ntinye.
- For current measurements (mA/A), insert the uhie test lead into the appropriate current input jack (e.g., mA/A or 10A FUSED), depending on the expected current level. Refer to the multimeter's faceplate for specific jack labels.
5. Ntuziaka ọrụ
5.1 Ọrụ izugbe
- Gbanyụọ/ Gbanyụọ: Rotate the central dial from the OFF position to any desired measurement function to turn the meter on. Rotate back to OFF to power off.
- Nhọrọ ọrụ: Use the central rotary dial to select the desired measurement function (e.g., V~ for AC Voltage, V- maka DC Voltage, Ω maka Nguzogide).
- Bọtịnụ oke: Pịa RANGE button to manually select a measurement range if auto-ranging is not desired. Press again to cycle through ranges or hold to return to auto-ranging.
- Bọtịnụ jide: Pịa Jide bọtịnụ iji mee ka ihe dị ugbu a dị na ngosipụta ahụ gbụchie. Pịa ọzọ ka ọ hapụ.
- Bọtịnụ ọkụ azụ: Press the backlight button (sun icon) to illuminate the display in low-light conditions.

Image: A gloved hand holding the Fluke 15B+ Digital Multimeter, demonstrating its ergonomic design.
5.2 Ọrụ Nha
5.2.1 AC/DC Voltage Ntụ
- Tụgharịa ọkpụkpọ rotary ka V~ (Mpịakọta ACtage) ma ọ bụ V- (DC Voltagna).
- Connect the black test lead to the COM terminal and the red test lead to the VΩHzCAP terminal.
- Carefully touch the test probes to the points where voltage is to be measured (in parallel with the circuit).
- Gụọ voltage uru na ngosi.
5.2.2 Nha AC/DC Ugbu a
Ịkpachara anya: Always ensure the circuit is de-energized before connecting the multimeter in series for current measurements. Incorrect connection can blow the fuse or damage the meter.
- Tụgharịa ọkpụkpọ rotary ka A~ (AC Current) or A- (DC Current).
- Jikọọ ụzọ ule ojii na ọdụ COM.
- For currents up to 400mA, connect the red test lead to the mA/A terminal. For currents up to 10A, connect the red test lead to the 10A FUSED Ọnụ.
- Open the circuit where current is to be measured and connect the multimeter in series.
- Re-energize the circuit and read the current value on the display.

Image: The Fluke 15B+ Digital Multimeter connected to an electrical panel, displaying a voltagna ịgụ.
5.2.3 Nledo Nguzogide
- Tụgharịa ọkpụkpọ rotary ka Ω (Resistance).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Ensure the component or circuit under test is de-energized.
- Touch the test probes across the component or circuit.
- Gụọ uru ndị na-eguzogide na ngosipụta.
5.2.4 Nnwale na-aga n'ihu
- Tụgharịa ọkpụkpọ rotary gaa na Na-aga n'ihu symbol (looks like a sound wave).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Ensure the circuit under test is de-energized.
- Touch the test probes across the points to be tested.
- The meter will beep if a continuous path (low resistance) is detected. The display will show the resistance value.
5.2.5 Diode Ule
- Tụgharịa ọkpụkpọ rotary gaa na Diode symbol (looks like an arrow with a bar).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Gbaa mbọ hụ na a kwụsịrị diode na sekit.
- Touch the red probe to the anode and the black probe to the cathode. A forward voltage drop (e.g., 0.5V to 0.8V for silicon diodes) should be displayed.
- Reverse the probes. The display should show OL (Open Loop) for a good diode.
5.2.6 Mmesho ikike
- Tụgharịa ọkpụkpọ rotary gaa na Ike symbol (looks like two parallel lines).
- Connect the black test lead to COM and the red test lead to VΩHzCAP.
- Ensure the capacitor is fully discharged before testing.
- Touch the test probes across the capacitor terminals.
- Gụọ uru capacitance na ngosipụta.

Image: A technician wearing safety gear, using the Fluke 15B+ Digital Multimeter to take a reading inside an electrical panel.
6. Nlekọta
6.1 Nhicha
Iji hichaa multimeter, hichaa akpa ahụ na mgbasa oziamp ákwà na ihe nchacha dị nro. Ejila ihe nchacha ma ọ bụ ihe mgbaze. Hụ na mita ahụ kpọrọ nkụ kpamkpam tupu e jiri ya.
6.2 nnọchi batrị
Replace the batteries when the low battery indicator appears on the display. Refer to Section 4.1 for battery installation instructions.
6.3 Mgbanwe Fuse
If the current measurement function stops working, the fuse may need replacement. Always replace with a fuse of the specified type and rating to maintain safety and performance.
- Ensure the multimeter is turned OFF and test leads are disconnected.
- Mepee mkpuchi nke batrị dịka akọwara na Nkebi nke 4.1.
- Carefully remove the old fuse.
- Install a new fuse of the correct type and rating (refer to the specifications section or the meter's internal markings).
- Replace the battery compartment cover and tighten the screw(s).
7. Nchọpụta nsogbu
- Enweghị Ngosipụta: Lelee ntinye batrị ma chajịa ya. Dochie batrị ma ọ bụrụ na ọ dị mkpa.
- Ọgụgụ na-ezighi ezi: Ensure test leads are correctly connected to the appropriate input jacks for the selected function. Verify the rotary dial is set to the correct measurement function. Check for damaged test leads.
- Nha ugbu a anaghị arụ ọrụ: Check the fuse. Replace if blown (refer to Section 6.3). Ensure the red test lead is in the correct current input jack.
- "OL" Display: This typically means "Overload" or "Open Loop." For resistance, it indicates an open circuit. For diode test, it indicates a reverse-biased good diode. For voltage/current, it means the measured value exceeds the selected range (if not in auto-range) or the meter's maximum capability.
8. Nkọwapụta
| Nkọwapụta | Uru |
|---|---|
| Nọmba nlereanya | FLUKE-15B+ |
| Ogo nchekwa | CAT III 600V |
| AC/DC Voltage | Ruo 1000V |
| AC/DC dị ugbu a | Ruo 10A |
| Nguzogide | Ee |
| Na-aga n'ihu | Ee |
| Nnwale Diode | Ee |
| Ike | Ee |
| Isi Iyi Ike | 2 batrị AA (gụnyere) |
| Akụkụ ngwaahịa | 8.46 x 2.76 x 5.91 sentimita asatọ |
| Ibu Ibu | 1.01 pound (gram 460) |
| Onye nrụpụta | Ụlọ ọrụ Fluke Corporation |
9. Akwụkwọ ikike na nkwado
The Fluke 15B+ Digital Multimeter is manufactured by Fluke Corporation. For detailed warranty information, technical support, or service, please refer to the official Fluke website or contact their customer service directly. Always ensure you purchase from authorized distributors to guarantee product authenticity and valid warranty coverage.
Maka akụrụngwa ndị ọzọ na ozi ngwaahịa, gaa na Fluke Store on Amazon.