1. Okwu mmalite
This manual provides essential information for the safe and efficient operation of your Cotek SP-3000-112 High Frequency Pure Sine Wave Inverter. This device converts 12V DC power from batteries into 120V AC power, suitable for a wide range of electronic appliances. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Ozi nchekwa
Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death. Always exercise caution when working with electrical equipment.
- Gụọ ntuziaka niile: Before operating the inverter, read all instructions and cautionary markings on the inverter, the batteries, and all appropriate sections of this manual.
- Ndị ọrụ tozuru oke: Installation and servicing should be performed by qualified personnel familiar with batteries and inverters.
- Igwe ikuku: Ensure adequate ventilation around the inverter. Do not install in a zero-clearance compartment.
- Zenarị mmiri: Do not expose the inverter to rain, snow, spray, or bilge water.
- Ndabere nke ọma: A ghaghị ịtọgbọ inverter ahụ nke ọma.
- Nchekwa batrị: Work near lead-acid batteries is dangerous. Batteries generate explosive gases during normal operation. Ensure proper ventilation and wear appropriate personal protective equipment.
- Kwụpụ ike: Always disconnect the battery supply before performing any maintenance or troubleshooting.
- Nke ziri ezi Voltage: Gbaa mbọ hụ na ntinye DC voltage matches the inverter's specifications (12VDC for this model).


3. Ngwaahịa gafereview
3.1 Atụmatụ
- Mmepụta ebili mmiri sine dị ọcha maka ngwa eletrọniki dị nro.
- Power ON / OFF remote control capability (Green Terminal).
- Input & output fully isolated for enhanced safety.
- Temperature & load controlled cooling fan for optimal performance.
- Njikọta dị mfe iji yana ihe ngosi ọnọdụ LED agba 3.
- Multiple protection features: Reverse Polarity (Fuse), Under Voltage / Over Voltage, Output Protection (Short Circuit / Overload / Over Temperature).
- E-13 / UL / CE / FCC approved.
3.2 Inverter Components




4. Ntọala na nwụnye
Proper installation is crucial for the safe and efficient operation of your inverter. Refer to local electrical codes and standards.
4.1 Ntinye
- Install the inverter in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
- Ensure sufficient clearance around the inverter for proper airflow, especially around the cooling fan vents.
- Mount the inverter securely on a stable, non-combustible surface.
- Avoid areas where dust, moisture, or corrosive fumes are present.
4.2 Waya
All wiring must comply with applicable electrical codes and be performed by a qualified electrician.
- Nda ala: Connect the inverter's chassis ground terminal to a reliable earth ground using appropriate gauge wire.
- Njikọ ntinye DC:
- Gbaa mbọ hụ na batrị batrị ahụ ruru ọkwatage bụ 12VDC.
- Use appropriately sized cables for the DC input to minimize voltage drop and ensure safety. Refer to cable sizing charts based on current and distance.
- Connect the positive (+) terminal of the battery bank to the red (+) terminal on the inverter.
- Connect the negative (-) terminal of the battery bank to the black (-) terminal on the inverter.
- Install a DC-rated fuse or circuit breaker between the battery bank and the inverter's positive terminal, as close to the battery as possible.
- Njikọ Mbupụ AC:
- Connect your AC loads to the hardwire AC output terminal block.
- Ensure the total load does not exceed the inverter's continuous power rating (3000W).
- Njikwa anya (Nhọrọ): Connect the remote control unit to the RJ45 port or use the green terminal for external ON/OFF control if desired.
5. Ntuziaka ọrụ
5.1 Gbanyụọ/ gbanyụọ
- Iji gbanye: Ensure all DC and AC connections are secure. Flip the main power switch on the inverter's rear panel to the 'ON' position. The Power LED indicator should illuminate.
- Iji gbanyụọ: Disconnect all AC loads from the inverter. Flip the main power switch to the 'OFF' position.
5.2 LED egosi
The inverter features 3-color LED status indicators on the control panel (refer to Figure 4) to provide operational feedback:
- Green ikanam: Indicates normal operation and power output.
- Ikanam edo edo: Indicates a warning condition, such as low battery voltage or high temperature. The inverter may continue to operate but requires attention.
- Red ikanam: Indicates a fault condition, such as overload, short circuit, or severe over/under voltage. The inverter will shut down to protect itself and connected devices.
5.3 Ntọala mgbanwe DIP
The DIP switches on the control panel allow for customization of certain inverter parameters, such as output voltage, frequency, and power saving mode. Refer to the detailed specifications table (Figure 5) or the product datasheet for specific configurations. Always adjust DIP switches when the inverter is powered off.
6. Nlekọta
Regular maintenance ensures the longevity and reliable operation of your inverter.
- Nhicha: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Njikọ: Regularly check all electrical connections (DC input, AC output, ground) for tightness and corrosion. Loose connections can cause overheating and poor performance.
- Nyocha batrị: Inspect batteries for signs of damage, corrosion, or electrolyte leakage. Ensure battery terminals are clean and tight.
- gburugburu: Nyochaa na gburugburu ebe ọrụ ka dị n'ime oke okpomọkụ na iru mmiri akọwapụtara.
7. Nchọpụta nsogbu
Nkebi a na-enye azịza maka nsogbu ndị ị na-enwekarị. Ọ bụrụ na nsogbu ahụ anọgide, kpọtụrụ ndị ọrụ nkwado ndị ahịa.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Inverter anaghị agbanye. | No DC input power; Loose battery connections; Blown DC fuse/breaker; Inverter switch OFF. | Lelee batrị voltage; Tighten connections; Replace fuse/reset breaker; Turn inverter switch ON. |
| Enweghị mmepụta AC. | Overload; Short circuit; Over-temperature shutdown; Low/High DC input voltage. | Reduce AC load; Check for short circuits in wiring/appliances; Allow inverter to cool; Check battery voltage. |
| Yellow LED illuminated. | Obere batrị voltage warning; High temperature warning. | Recharge batteries; Ensure adequate ventilation, reduce load. |
| Red LED illuminated / Inverter shut down. | Overload; Short circuit; Over-temperature; Under/Over voltage. | Identify and correct the fault (e.g., reduce load, fix short, allow cooling, check battery voltage), then restart the inverter. |
| Cooling fan runs constantly or loudly. | High internal temperature due to heavy load or poor ventilation. | Reduce load; Improve ventilation around the inverter. |
8. Nkọwapụta
The following table outlines the technical specifications for the Cotek SP-3000 Series Pure Sine Wave Inverter, specifically for the SP-3000-112 model.

| Otu | Oke | SP-3000-112 |
|---|---|---|
| Mpụta | AC Voltage | 100/110/115/120VAC ±5% |
| Enyere ike | 3000W | |
| Surge Power (1 Sec.) | 6000W | |
| Maximum Output Power (1 Min) | 3450W | |
| Mmepụta Waveform | Pure Sine Wave (THD<3%) | |
| Ugboro ugboro | 50/60 Hz ± 0.5% | |
| Ntinye | DC Voltage | 12VDC |
| Voltage Oke | 10.5 ~ 16.5VDC | |
| Enweghị ibu ugbu a | <3.0A@12VDC | |
| Ụdị Nchekwa Ike | <0.4A@12VDC | |
| arụmọrụ (Max.) | 90% | |
| Nchedo | Input Under - Voltage Nchedo | 10.5 ± 0.3VDC |
| Input Under - Voltagmkpu | 11.0 ± 0.3VDC | |
| Input Under - Voltage Iweghachite | 12.0 ± 0.3VDC | |
| Input Over - Voltage Nchedo | 16.5 ± 0.3VDC | |
| Input Over - Voltage Iweghachite | 14.5 ± 0.3VDC | |
| Mbufe oke | Mmechi mmechi voltage, restart to recover | |
| Mmepụta Short | Mmechi mmechi voltage, restart to recover | |
| gburugburu | Okpomọkụ na-arụ ọrụ. | -20°C ~ +40°C |
| Okpomọkụ nchekwa. & iru mmiri | -30°C ~ +70°C, 10 ~ 95% RH | |
| Izugbe | Akụkụ (W x H x D) | 442 x 214 x 102 mm (17.4 x 8.4 x 4.0 inch) |
| Ibu | 8.2kg (18.1 lbs) | |
| Na-ajụ oyi | Temperature & load controlled cooling fan |

9. Akwụkwọ ikike na nkwado
9.1 Ozi akwụkwọ ikike
The Cotek SP-3000-112 Pure Sine Wave Inverter comes with a Akwụkwọ ikike nke onye nrụpụta afọ 2. Akwụkwọ ikike a na-ekpuchi ntụpọ dị na ngwa na arụ ọrụ n'okpuru ojiji nkịtị. Biko dowe ihe akaebe nke ịzụrụ ihe maka akwụkwọ ikike.
9.2 Nkwado ndị ahịa
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Cotek customer support through their official website or your point of purchase. Provide your model number (SP-3000-112) and a detailed description of the issue to expedite service.