1. Okwu mmalite
The Jebao APP-2000 Pond & Waterfall Pump is a high-performance, energy-efficient submersible pump designed for use in fish ponds, fountains, and waterfalls. This manual provides essential information for the safe and effective installation, operation, and maintenance of your pump.
Akụkụ ndị bụ isi:
- Versatile design suitable for various water garden applications.
- Powerful, efficient magnetic drive motor.
- Fish-safe operation due to oil-free design.
- Heavy-duty pre-filter with increased surface area to resist clogging.
- Capable of pumping particles up to 6mm in size.
- Designed for continuous duty operation.
- Completely submersible and UL Listed for safety.
- Equipped with a 28-foot long power cord with a 3-prong US plug.
2. Ntuziaka nchekwa
Read all instructions carefully before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Nchekwa Eletriki: Always connect the pump to a properly grounded outlet. Do not modify the plug or use an adapter. Ensure the power cord is free from damage.
- Ntinye mmiri: The pump must be fully submerged in water during operation. Operating the pump dry will cause damage and void the warranty.
- Okpomọkụ mmiri: Do not operate the pump in water exceeding 95°F (35°C) or below freezing temperatures.
- Ijikwa: Disconnect power before handling or performing any maintenance on the pump.
- Ezubere iji: This pump is designed for water garden and pond use only. Do not use for swimming pools, potable water, or with flammable or corrosive liquids.
- Ụmụaka na anụ ụlọ: Keep children and pets away from the pump and water feature during operation and maintenance.
3. Ihe ngwugwu
Chọpụta na ihe niile dị na ngwugwu:
- Jebao APP-2000 Pond & Waterfall Pump
- Hose Adapter (multi-size)
- Akwụkwọ ntuziaka

Image: The Jebao APP-2000 pump with its included multi-size hose adapter attached to the outlet.

Image: The Jebao APP-2000 pump showing its long, coiled 28-foot power cord.
4. Nhazi
- Họrọ ebe: Select a suitable location in your pond or water feature where the pump can be fully submerged and will not pump air. Ensure the location allows for easy access for maintenance.
- Tinye ihe nkwụnye ọkụ: Connect the multi-size hose adapter to the pump's outlet. Securely attach your desired hose (3/4" ID to 1-1/2" ID flexible tubing) to the appropriate barb on the adapter.
- Igwe mgbapụta ọnọdụ: Carefully place the pump into the water, ensuring it is completely submerged. The pump should rest on a stable surface to prevent movement.
- Njikọ Ike: Route the 28-foot power cord to a grounded 110V AC outlet. Ensure the cord is not pinched or damaged.
5. Ntuziaka ọrụ
Once the pump is set up and fully submerged:
- Ike Na: Plug the pump's power cord into the grounded electrical outlet. The pump will begin to operate immediately.
- Verify Flow: Check that water is flowing correctly through your hose to the waterfall, fountain, or filter system.
- Ọrụ na-aga n'ihu: The Jebao APP-2000 pump is designed for continuous duty operation.
6. Nlekọta
Nlekọta anya mgbe niile na-eme ka arụmọrụ dị mma ma gbasaa ndụ nke mgbapụta gị.
- Kwụpụ ike: Kwapụ pampụ ahụ mgbe niile site na isi iyi ike tupu ị rụọ ọrụ ọ bụla.
- Clean Pre-filter: Periodically inspect and clean the pre-filter housing to remove debris, leaves, and other particles that may reduce flow or cause clogging. The heavy-duty pre-filter is designed to resist clogging, but regular cleaning is still recommended.
- Inspect Impeller: Remove the pre-filter and inspect the impeller for any obstructions or damage. Clear any debris carefully. The pump features a wear-proof ceramic shaft for longer life.
- Oge oyi: In freezing climates, remove the pump from the pond before winter. Clean it thoroughly and store it in a frost-free location, submerged in a bucket of water if possible, to keep seals moist.
7. Nchọpụta nsogbu
If your pump is not operating as expected, consult the following common issues:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Mgbapụ anaghị amalite ma ọ bụ na-agba ọsọ mgbe ụfọdụ. | No power, clogged impeller, thermal overload. | Check power connection. Disconnect power, clean impeller and pre-filter. Allow pump to cool if thermal overload is suspected. |
| Mbelata mmiri eruba. | Clogged pre-filter, kinked hose, pump not fully submerged. | Disconnect power, clean pre-filter. Check hose for kinks or blockages. Ensure pump is fully submerged. |
| Oke mkpọtụ ma ọ bụ ịma jijiji. | Debris in impeller, pump not stable, air in pump. | Disconnect power, clean impeller. Ensure pump is on a flat, stable surface. Verify pump is fully submerged and not drawing air. |
If troubleshooting steps do not resolve the issue, contact Jebao customer support.
8. Nkọwapụta
| Nlereanya | APP-2000 |
| Ọnụego ebugharị (GPH) | Ihe dị ka 2000 GPH |
| Kachasị Elu Elu | 16.4 ụkwụ |
| Isi Iyi Ike | AC 110V |
| Ugbu a | 1.20A |
| Akụkụ ngwaahịa (L x W x H) | 9" x 4" x 5.5" |
| Ibu Ibu | 7 pound |
| Ihe onwunwe | Plastic |
| Ụdị | Na-asọba mmiri |
| Ngwa gụnyere | Water Pump, Hose adapter |
| Asambodo | Edepụtara UL |

Image: Dimensional diagram of the Jebao APP-2000 pump, indicating its length, width, and height.
9. Akwụkwọ ikike na nkwado
For warranty information, please refer to the documentation included with your product or visit the official Jebao website. For technical support or further assistance, please contact Jebao customer service.
Onye nrụpụta: Jebao
Nọmba nlereanya: APP-2000
UPC: 651046601449