1. Okwu mmalite
Thank you for choosing the BESTTEN 1U PDU Rack Mount Power Strip. This unit is designed to provide reliable power distribution and surge protection for your electronic equipment, particularly in server racks or similar installations. Please read this manual thoroughly before installation and operation to ensure safe and optimal performance.
2. Ntuziaka nchekwa
- Nchekwa Eletriki: Always connect the PDU to a properly grounded outlet. Do not remove the grounding prong.
- Nchekwa ibu ibu: Do not exceed the maximum electrical rating of 15A/125V/1875W. Overloading can cause damage to the unit and connected devices, and may pose a fire hazard.
- Eji ime ụlọ naanị: A na-eme ngwaahịa a maka ojiji n'ime ụlọ n'ebe kpọrọ nkụ. Etinyela ya n'ebe mmiri na-anaghị eru oke okpomọkụ.
- Zere Tampihe: Do not attempt to open, modify, or repair the unit. Refer all servicing to qualified personnel.
- Njikwa ụdọ: Ensure the power cord is not pinched, walked on, or placed under heavy objects.
- Ụmụaka na anụ ụlọ: Debe ebe ụmụaka na anụ ụlọ na-apụghị iru.
3. Ihe ngwugwu
- BESTTEN 1U PDU Rack Mount Power Strip (Model USM-0U8A-9C)
- Akwụkwọ ntuziaka
Note: Mounting hardware (screws) may not be included and should be sourced separately if needed for your specific installation.
4. Akụrụngwa Ngwaahịa
- 8 Oghere AC: Na-enye ample power connections for multiple devices.
- eriri ike nke ụkwụ 9: Offers flexibility in placement and reach.
- Nchekwa 900 Joules: Safeguards connected electronics from power surges and spikes.
- Heavy-Duty Metal Housing: Durable construction for demanding environments.
- 1U Rack Mountable Design: Easily integrates into standard 19-inch server racks.
- Illuminated Power Switch: Controls power to all outlets and indicates operational status.
- ETL edepụtara: Asambodo maka nchekwa yana ụkpụrụ ịdị mma.
5. Ntọala na nwụnye
The BESTTEN 1U PDU is designed for versatile installation, including rack mounting or surface mounting.

Figure 1: BESTTEN 1U PDU Rack Mount Power Strip. This image displays the BESTTEN 1U PDU Rack Mount Power Strip. It features a black metal housing with eight standard AC outlets arranged linearly. A red illuminated power switch and a 'SurgePro' indicator are visible at one end. A coiled 9-foot power cord with a standard three-prong plug extends from the unit. Mounting brackets are visible at both ends for rack installation.
5.1 Rack arịọnụ
- Identify an available 1U space in your standard 19-inch server rack.
- Align the mounting brackets on both ends of the PDU with the rack posts.
- Secure the PDU to the rack using appropriate rack screws (not included). Ensure it is firmly attached.
5.2 Surface Mounting (e.g., under desk, wall)
- Choose a flat, stable surface for mounting.
- Use the mounting brackets on the PDU as a template to mark screw locations.
- Gwuo oghere ndị na-anya ụgbọelu ma ọ dị mkpa.
- Secure the PDU to the surface using appropriate screws (not included). Ensure it is firmly attached and stable.
5.3 Ijikọ n'ike
- Once the PDU is securely mounted, plug its 9-foot power cord into a grounded 125V AC wall outlet.
- The power switch on the PDU should illuminate when power is supplied and the switch is in the 'ON' position.
6. Ntuziaka ọrụ
6.1 Gbanyụọ/ gbanyụọ
- To turn on the PDU and supply power to its outlets, press the red illuminated power switch to the 'ON' position. The switch will light up.
- To turn off the PDU and cut power to all connected devices, press the power switch to the 'OFF' position. The light will extinguish.
6.2 Ngwa jikọọ
- Plug your electronic devices into the 8 AC outlets on the PDU.
- Ensure that the total power draw of all connected devices does not exceed the PDU's maximum rating of 1875W (15A at 125V).
6.3 Nchekwa ịwa ahụ
This PDU includes 900 Joules of surge protection to shield your connected equipment from voltage spikes. In the event of a significant power surge, the surge protection feature will activate to absorb the excess energy. If the surge protection is compromised, the 'SurgePro' indicator light (if present and functional) may turn off or change color, indicating that the unit no longer provides surge protection. In such a case, the unit should be replaced.
7. Nlekọta
- Nhicha: Disconnect the PDU from the power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- Nyocha: Periodically inspect the power cord and the PDU for any signs of damage, such as frayed wires, cracks, or loose connections. If damage is found, discontinue use and replace the unit.
- Outlet Caps: The unit may come with safety caps for unused outlets. Use these to prevent dust accumulation and accidental contact.
8. Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| PDU has no power / Power switch light is off. |
|
|
| Connected devices are not receiving power. |
|
|
| 'SurgePro' indicator light is off. |
|
|
9. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nọmba nlereanya | USM-0U8A-9C |
| Mkpokọta ọdụ ọkụ | 8 |
| Voltage Ntụle | 125 volts |
| Ogo dị ugbu a | 15 Amps |
| Oke ike kacha | 1875 Watt |
| Nchedo ịwa ahụ | 900 Joules |
| Ogologo eriri | 9 ụkwụ |
| Akụkụ ngwaahịa | 19 x 1.75 x 1.75 sentimita asatọ |
| Ibu Ibu | 2.11 pound |
| Ihe onwunwe | Ọla dị arọ |
| Asambodo | ETL edepụtara |
10. Akwụkwọ ikike na nkwado
BESTTEN products are manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your purchase or visit the official BESTTEN website. If you encounter any issues or have questions regarding your BESTTEN 1U PDU, please contact BESTTEN customer support for assistance.
Websaịtị: Visit the BESTTEN Store on Amazon