Ohaus PA4102C

OHAUS PA4102C Pioneer Precision Balance User Manual

1. Okwu mmalite

This manual provides essential instructions for the proper installation, operation, and maintenance of your OHAUS PA4102C Pioneer Precision Balance. To ensure accurate results and prolong the lifespan of your instrument, please read this manual thoroughly before use and keep it for future reference.

The OHAUS PA4102C is a precision laboratory balance designed for accurate weighing applications, featuring a 4100g capacity and internal calibration for reliable performance.

2. Ozi nchekwa

  • Operate the balance only under the environmental conditions specified in this manual.
  • Gbaa mbọ hụ na ọkọnọ ọkụ voltage matches the requirements specified on the balance.
  • Do not operate the balance in hazardous environments or with unstable power sources.
  • Avoid spilling liquids or powders into the balance housing.
  • Do not attempt to open or service the balance yourself. Refer all servicing to qualified personnel.
  • Always place the balance on a stable, level surface away from vibrations, drafts, and direct heat sources.

3. Ngwaahịa gafereview

The OHAUS PA4102C Pioneer Precision Balance is engineered for reliable and precise weighing. Key features include a clear digital LCD display, a front-mounted bubble level for easy leveling, and selectable environmental settings to adapt to various operating conditions.

OHAUS Pioneer Precision Balances, illustrating models with and without a draft shield

An image showing two OHAUS Pioneer precision balances. The balance on the left features a transparent draft shield, typically used for higher precision models. The balance on the right is a simpler model without a draft shield, designed for general weighing tasks. Both balances have a digital LCD display and a stainless steel weighing pan. The PA4102C model is a precision balance with a 4100g capacity and internal calibration.

4. Nhazi

4.1 Nwepu

Carefully remove the balance and all accessories from the packaging. Retain the packaging for future transport or storage.

4.2 Ntinye

Place the balance on a firm, stable, and level surface. Ensure the location is free from vibrations, drafts, direct sunlight, and rapid temperature changes. Allow the balance to acclimate to the room temperature for at least 30 minutes before operation.

4.3 Leveling the Balance

Adjust the leveling feet located at the base of the balance until the air bubble in the front-mounted level indicator is centered within the circle. This ensures accurate weighing results.

4.4 Njikọ ike

Connect the supplied AC adapter to the balance and then to a suitable power outlet. The balance may perform a self-test upon initial power-up.

4.5 Nhazi mbụ

The PA4102C features internal calibration. After initial setup and warm-up, it is recommended to perform an internal calibration. Refer to the operating instructions section for details on initiating the internal calibration procedure.

5. Ntuziaka ọrụ

5.1 Gbanyụọ / gbanyụọ

  • Iji gbanye: Pịa [Gbanye/ Gbanyụọ] button. The display will show a self-test sequence and then settle at 0.00g.
  • Iji gbanyụọ: Pịa ma jide [Gbanye/ Gbanyụọ] bọtịnụ ruo mgbe ngosi gbanyụọ.

5.2 Ibu Ibu Dị Mkpa

  1. Ensure the balance is level and displaying 0.00g.
  2. Carefully place the item to be weighed onto the center of the weighing pan.
  3. Wait for the stability indicator (usually a star or circle) to appear on the display.
  4. Read the stable weight value from the digital LCD display.

5.3 Taring (Zeroing a Container)

  1. Place an empty container onto the weighing pan.
  2. Pịa [TARE] or [ZERO] button. The display will return to 0.00g.
  3. Add the material to be weighed into the container. The display will show the net weight of the material.

5.4 Nhọrọ nkeji

Pịa [UNIT] button (if available) to cycle through available weighing units (e.g., grams, kilograms, milligrams, ounces). The selected unit will be indicated on the display.

5.5 Environmental Settings

The balance allows selection of environmental settings to optimize performance in varying conditions. Consult the on-screen menu or specific button functions to adjust these settings (e.g., for stable, normal, or unstable environments). This helps to compensate for drafts or vibrations.

6. Nlekọta

6.1 Nhicha

Clean the balance regularly using a soft cloth dampened with a mild detergent or water. Do not use abrasive cleaners, solvents, or harsh chemicals. Ensure no liquids enter the balance housing.

6.2 Calibration Checks

Although the PA4102C has internal calibration, it is recommended to periodically verify its accuracy using external calibration weights. If discrepancies are found, perform an internal calibration.

6.3 Nchekwa

When not in use for extended periods, disconnect the power adapter and store the balance in a clean, dry, and stable environment, ideally in its original packaging.

7. Nchọpụta nsogbu

  • Ọgụgụ na-adịghị akwụsi ike: Check for drafts, vibrations, or temperature fluctuations. Ensure the balance is level. Recalibrate if necessary.
  • Display Shows 'Error': Refer to the balance's on-screen error codes (if any) or consult the manufacturer's support. Often, this indicates an overload or internal fault.
  • Balance Does Not Turn On: Verify the power adapter is correctly connected and the power outlet is functional.
  • Ọgụgụ na-ezighi ezi: Ensure the balance is level and has been calibrated recently. Check for debris under the weighing pan.

8. Nkọwapụta

NjirimaraNkọwapụta
ỤdịOhaus
Nọmba nlereanyaPA4102C (Article No. 001530)
Ike4100 g
nhazi nhaziNhazi nhazi
NgosipụtaDigital LCD (without backlight)
ỊkwadoFront Bubble Level
Ntọala gburugburuSelectable for optimal adaptation
Nha ngwugwu dị ka nha10 x 10 x 10 cm
Odika Ngwungwu Ibu10 kilogram
Ihe onwunweMgbe niile

9. Akwụkwọ ikike na nkwado

For warranty information, please refer to the warranty card included with your product or contact your authorized OHAUS dealer. Technical support can be obtained by contacting OHAUS customer service directly or through your local distributor. Please have your model number (PA4102C) and serial number ready when requesting support.

Akwụkwọ ndị emetụtara - PA4102C

Tupuview OHAUS Scout STX Balances: Ntuziaka mmalite ngwa ngwa
Ntuziaka mmalite ngwa ngwa zuru oke maka itule OHAUS Scout STX, na-akọwa mwepu, nhazi, ịrụ ọrụ, nhazigharị, ịkpachara anya nchekwa, yana atụmatụ ndị ọzọ.
Tupuview OHAUS Explorer Plus™ Balances Instruction Manual - Comprehensive Guide
Detailed instruction manual for OHAUS Explorer Plus™ balances, covering installation, operation, weighing applications, menu settings, maintenance, and technical specifications for precise laboratory weighing.
Tupuview OHAUS Explorer™ Balances: Comprehensive Instruction Manual for Precision Weighing
This comprehensive instruction manual provides detailed guidance on the installation, operation, maintenance, and technical specifications of OHAUS Explorer™ balances, designed for laboratory and industrial weighing applications.
Tupuview OHAUS Explorer™ EXR Balances: Comprehensive Instruction Manual
Detailed guide for OHAUS Explorer™ EXR laboratory balances, covering installation, operation, features, weighing modes, settings, and technical specifications for accurate laboratory weighing.
Tupuview OHAUS Explorer Plus™ Balances Instruction Manual
Detailed instruction manual for OHAUS Explorer Plus™ balances, covering features, operation, application modes, maintenance, and technical specifications for precise laboratory weighing.
Tupuview OHAUS Adventurer Pro Balances Instruction Manual
Comprehensive instruction manual for OHAUS Adventurer Pro balances, covering installation, operation, maintenance, technical specifications, and troubleshooting for precision weighing instruments.