1. Okwu mmalite
Ihe ndekọTag UTRIX-16 is a high-performance, multi-use temperature data logger designed for reliable and accurate monitoring across a wide range of applications. This device records temperature data and generates comprehensive PDF reports without requiring special software or hardware. Its integrated USB connector allows for easy data transfer and configuration.
2. Ozi nchekwa
- Do not expose the device to extreme physical shock or vibration.
- Avoid immersing the device in liquids.
- Do not attempt to open or modify the device, as this will void the warranty and may cause damage.
- Tụfuo batrị dịka iwu mpaghara siri dị.
- Ensure the USB connector is clean and dry before connecting to a computer.
3. Ihe ngwugwu
Chọpụta na ihe niile dị na ngwugwu:
- NdekọTag UTRIX-16 PDF Temperature Data Logger
- Akwụkwọ ntuziaka (akwụkwọ a)
4. Ngwaọrụ gafereview
The UTRIX-16 features a compact design with clear indicators and control buttons.
Foto 1: N'ihu view of the LogTag UTRIX-16 PDF Temperature Data Logger. This image displays the device's front panel, showing the "ALERT" and "OK" indicator lights, and the "STOP" and "START/Mark" buttons. The LogTag brand and "USB PDF TEMPERATURE RECORDER" text are visible, along with a serial number barcode.
- ALERT Indicator: Flashes when a pre-configured temperature alert threshold has been exceeded.
- OK Indicator: Flashes to confirm normal operation and within-range temperature readings.
- Bọtịnụ Kwụsị: Press to stop the current logging session.
- START/Mark Button: Press to start a new logging session or to insert a mark into the data stream during logging.
- Integrated USB Connector: Located at the bottom, used for connecting to a computer for configuration and data download.
Foto 2: Ihe ndekọTag UTRIX-16 with its integrated USB connector extended. This view highlights the USB-A plug, ready for connection to a computer's USB port, facilitating direct data transfer and device configuration.
5. Nhazi
5.1 Nhazi izizi
The UTRIX-16 is typically pre-configured for immediate use. However, for custom settings (e.g., logging interval, alert thresholds, start delay), you will need to use the LogTag Analyzer software. This software is available for download from the official LogTag websaịtị.
- Download and install the LogTag Akụrụngwa nyocha sitere na NdekọTag Recorders Software.
- Connect the UTRIX-16 to a USB port on your computer.
- Ihe ndekọTag Analyzer software should automatically detect the connected device.
- Follow the on-screen prompts within the software to configure logging parameters as needed.
Foto 3: Ihe ndekọTag UTRIX-16 data logger connected to a computer's USB port. This illustrates the direct connection method for data download and configuration, eliminating the need for a separate interface cradle.
5.2 Ozi batrị
The UTRIX-16 uses a CR2 battery (included). The battery is designed for long life and is generally not user-replaceable without specialized tools. If battery replacement is required, it is recommended to contact LogTag support or an authorized service center.
6. Ọrụ
6.1 Starting a Logging Session
To start a new logging session:
- Ensure the device is not currently logging (check the OK/ALERT indicators).
- Pịa ma jide Malite/Mark button for approximately 5 seconds until the OK indicator flashes rapidly.
- Release the button. The OK indicator will flash at regular intervals, indicating that logging has started.
6.2 Stopping a Logging Session
To stop an active logging session:
- Pịa ma jide KWỤSỊ button for approximately 5 seconds until the ALERT indicator flashes rapidly.
- Release the button. The device will cease logging.
6.3 Marking Data
During an active logging session, you can insert a mark into the data stream:
- Pịa nkenke Malite/Mark button (less than 2 seconds).
- A mark will be recorded in the data, visible when the data is downloaded and analyzed.
7. Data Retrieval and Reporting
The UTRIX-16 generates a PDF report directly when connected to a computer.
- Connect the UTRIX-16 to a USB port on your computer.
- The device will appear as a removable drive.
- Locate and open the generated PDF report file. This report contains a summary of the logging session, temperature graphs, and statistical data.
- For advanced analysis and configuration, use the LogTag Akụrụngwa nyocha.
8. Nlekọta
8.1 Nhicha
Wipe the device clean with a soft, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
8.2 nnọchi batrị
The battery in the UTRIX-16 is designed for extended use and is not intended for user replacement. If the battery life is depleted, contact LogTag support for service options.
9. Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Device does not start logging. | Incorrect button press duration; device already logging; battery depleted. | Ensure the START/Mark button is held for approximately 5 seconds. Check if the device is already logging. Connect to LogTag Analyzer to check battery status. |
| Kọmputa anaghị amata ngwaọrụ ahụ. | Loose USB connection; faulty USB port; driver issue. | Ensure the USB connector is fully inserted. Try a different USB port. Reinstall LogTag Akụrụngwa nyocha. |
| No PDF report generated. | Logging session not completed; device not recognized as a drive. | Ensure the logging session has been stopped. Verify the device appears as a removable drive. |
| ALERT indicator flashing. | Temperature exceeded pre-set limits. | This indicates an alert condition. Review the PDF report or LogTag Analyzer data to identify when and for how long the limits were exceeded. |
10. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nọmba nlereanya | UTRIX-16 |
| Oke okpomọkụ | -25°C ruo +70°C (-13°F ruo +158°F) |
| Njikọta | USB agbakwunyere |
| Isi Iyi Ike | 1 CR2 batrị (gụnyere) |
| Akụkụ ngwaahịa | 3.66 x 2.15 x 0.34 sentimita asatọ |
| Ibu | 1.27 ounces |
| Ihe onwunwe | Plastic |
| Njirimara Pụrụ Iche | High Accuracy, PDF Reporting |
11. Akwụkwọ ikike na nkwado
NdekọTag products are manufactured to high standards. For warranty information and technical support, please refer to the official LogTag websaịtị ma ọ bụ kpọtụrụ onye nkesa mpaghara gị. Debe nnata nzụta gị ka ihe akaebe nke ịzụrụ.
Official LogTag Websaịtị: www.logtag-recorders.com





