1. Okwu mmalite
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Grundfos UPS15-58FRC 3-Speed Circulation Pump. Please read these instructions carefully before installation and retain them for future reference.
1.1 Ozi nchekwa
Ịdọ aka ná ntị: Electrical shock hazard. Ensure power is disconnected before installation or servicing. All electrical work must be performed by a qualified electrician in accordance with local codes and regulations.
kpachara anya: Hot surfaces. The pump and connected piping may become hot during operation. Allow to cool before handling. Wear appropriate personal protective equipment.
- Do not operate the pump without liquid.
- Gbaa mbọ hụ na ntọ ala kwesịrị ekwesị.
- Debe ụmụaka na ndị ọrụ na-enweghị ikike na mgbapụta mgbe a na-arụ ọrụ.
2. Akụrụngwa Ngwaahịa
The Grundfos UPS15-58FRC is a robust and reliable circulation pump designed for various water circulation applications. Key features include:
- Durable Cast Iron Construction: Provides extended lifespan and protection against corrosion.
- 3-arụ ọrụ ọsọ: Allows for adjustment of flow rates to suit specific system requirements.
- Integrated Flow Check Valve: Limits water flow to a single direction, preventing backflow.
- Arụ ọrụ dị jụụ: Engineered for low noise levels during use.
- Hardwire Electrical Connection: Designed for direct connection to your electrical supply.

Figure 1: Grundfos UPS15-58FRC 3-Speed Circulation Pump. This image shows the compact design and cast iron housing of the pump.
3. Ntọala na nwụnye
Installation of the Grundfos UPS15-58FRC pump should be performed by a qualified professional to ensure proper function and adherence to all local plumbing and electrical codes.
3.1 Na-arịgo
- Choose a suitable location that allows for easy access for maintenance and is protected from freezing temperatures.
- Ensure the pump is mounted securely to a stable surface, minimizing vibration.
- The pump should be installed with the motor shaft in a horizontal position for optimal performance and longevity.
3.2 Njikọ Plumbing
- Connect the pump to the piping system using appropriate fittings. Ensure all connections are watertight.
- Observe the flow direction arrow on the pump housing to ensure correct installation relative to the system flow. The integrated check valve will enforce this direction.
- Avoid placing excessive strain on the pump connections from misaligned piping.
3.3 Igwe ọkụ eletrik
- Ịdọ aka ná ntị: Disconnect power at the main circuit breaker before beginning any electrical work.
- Wire the pump according to the wiring diagram provided on the pump's terminal box cover and local electrical codes.
- Gbaa mbọ hụ na ntọ ala kwesịrị ekwesị iji gbochie ihe egwu eletrik.
- Chọpụta na ọkọnọ voltage kwekọrọ na ihe mgbapụta ahụ chọrọ.
4. Ntuziaka ọrụ
Once installed and filled with liquid, the Grundfos UPS15-58FRC pump is ready for operation.
4.1 Mmalite mbụ
- Ensure the system is completely filled with water and properly vented to remove any air. Air in the system can damage the pump.
- Weghachite ike na mgbapụta.
- The pump will begin operating at the selected speed. Listen for unusual noises, which may indicate air in the system or an installation issue.
4.2 Nhọrọ ọsọ ọsọ
The UPS15-58FRC features a 3-speed selector switch, typically located on the motor housing. Adjust the switch to select the desired speed (I, II, or III) based on your system's flow requirements. Higher speeds provide greater flow and head.
- Ọsọ I: Lowest flow/head.
- Ọsọ II: Medium flow/head.
- Ọsọ nke atọ: Highest flow/head.
5. Nlekọta
The Grundfos UPS15-58FRC pump is designed for reliable operation with minimal maintenance. Regular inspections can help ensure its longevity.
- Nyocha kwa afọ: Check for any signs of leaks around the pump or piping connections.
- Nyochaa mkpọtụ: Listen for any unusual noises during operation, which could indicate air in the system or a mechanical issue.
- Ịdị ọcha: Keep the pump and surrounding area clean and free from debris to ensure proper ventilation and prevent overheating.
- Oge oyi: If the pump is installed in an area subject to freezing temperatures, ensure the system is properly drained or protected from freezing when not in use.
No lubrication or other routine servicing of internal components is typically required for this sealed unit.
6. Nchọpụta nsogbu
Before attempting any troubleshooting, ensure the power supply to the pump is disconnected. If you are unable to resolve an issue, contact a qualified technician.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Mgbapụta anaghị amalite ma ọ bụ na-agba ọsọ. | Enweghị ọkụ. Wiwi na-ezighi ezi. Motor seized. | Lelee ihe nbibi/fuse sekit. Nyochaa njikọ eletrik. Kpọtụrụ onye ọrụ nka tozuru oke. |
| Pump runs but no flow or low flow. | Ikuku na usoro. valves mechiri emechi. Pump installed against flow direction. Mkpọchi akpọchiri. | Wepụ sistemu ahụ. Open all necessary valves. Check pump installation direction. Kpọtụrụ onye ọrụ nka tozuru oke. |
| Mkpọtụ ma ọ bụ ịma jijiji na-adịghị ahụkebe. | Ikuku na usoro. Nkwalite rụrụ arụ. Foreign object in pump. Bearings na-eyi. | Wepụ sistemu ahụ. Gbanyụọ bolts mgbago. Kpọtụrụ onye ọrụ nka tozuru oke. |
| Leakage from pump. | Njikọ rụrụ arụ. Akara mebiri emebi. | Tighten pipe connections. Contact a qualified technician for seal replacement. |
7. Nkọwapụta
| Ụdị: | UPS15-58FRC |
| Akara: | Grundfos |
| Ike inyinya (HP): | 1 / 25 HP |
| Ọsọ ọsọ: | 3-Ọsọ |
| Ihe: | Nkedo Ígwè |
| Isi mmalite ike: | Igwe ọkụ eletrik |
| Atụmatụ agbakwunyere: | Nleba anya mmiri |
8. Akwụkwọ ikike na nkwado
For detailed warranty information, please refer to the official Grundfos website or the warranty card included with your product. For technical support or service inquiries, please contact Grundfos customer service directly.
Ị nwere ike ịchọta ozi kọntaktị na onye ọrụ mmepụta ihe websaịtị: www.grundfos.com