1. Okwu mmalite
This manual provides essential information for the proper installation, operation, and maintenance of your Sartorius Cubis Balance MSA2202S100D0. The Cubis Balance is a precision toploading instrument designed for accurate mass determination in laboratory and industrial settings. It features a high-resolution color TFT touchscreen, integrated software, and advanced functions such as automatic internal calibration (isoCAL) and motorized leveling.
2. Ozi nchekwa
Observe the following safety precautions to ensure safe operation and to prevent damage to the balance or injury to personnel:
- Operate the balance only in a stable, level environment free from vibrations and drafts.
- Gbaa mbọ hụ na ọkọnọ ọkụ voltage matches the requirements specified for the balance.
- Do not expose the balance to extreme temperatures, humidity, or direct sunlight.
- Avoid spilling liquids on the balance. If spills occur, disconnect power and clean immediately.
- Naanị ndị ọrụ tozuru etozu kwesịrị ịrụzi ma ọ bụ rụzie ya.
3. Ihe ngwugwu
Nyochaa na ihe niile dị na adịghị emebi emebi mgbe ebupụ ya:
- Sartorius Cubis Balance MSA2202S100D0
- Universal power supply with 120V line cord
- Akwụkwọ ntuziaka (akwụkwọ a)
- Standard factory certificate of conformity to specifications
4. Nhazi
4.1 Mwepu na ntinye
Carefully remove the balance from its packaging. Place the balance on a stable, level, and vibration-free surface. Ensure adequate space around the balance for operation and ventilation. Avoid locations near air conditioning vents, open windows, or heavy machinery that could cause air currents or vibrations.

Figure 1: Sartorius Cubis Balance MSA2202S100D0. This image shows the balance from an angled front view, highlighting the stainless steel weighing pan, the white housing, and the integrated color TFT touchscreen display showing "0.00" g.
4.2 Njikọ ike
Connect the universal power supply to the balance and then plug the 120V line cord into a suitable electrical outlet. The balance will perform an initial self-test upon power-up.
4.3 Ịkwado
The Cubis Balance features automatic motorized leveling. Upon initial setup or relocation, the balance will prompt for leveling or can be initiated via the touchscreen interface. Follow the on-screen instructions to ensure the balance is perfectly level for accurate measurements.
4.4 Initial Calibration (isoCAL)
The balance is equipped with isoCAL, a fully automatic internal temperature- and time-controlled calibration function. It is recommended to perform an initial isoCAL cycle after setup and before first use to ensure optimal accuracy. This can be initiated through the balance's menu system.
5. Ntuziaka ọrụ
5.1 Ihuenyo mmetụ
The balance features a 5.7" high-resolution color TFT touchscreen. This interface provides interactive guidance for managing weighing tasks, user settings, and system settings. Basic functions can also be accessed via the physical keypad buttons surrounding the screen.
5.2 Ibu Ibu Dị Mkpa
- Ensure the weighing pan is clean and empty.
- Pịa Tare button (if applicable) or use the touchscreen to zero the balance.
- Jiri nlezianya tinye sample on the center of the weighing pan.
- Read the stable weight displayed on the screen.
- Wepu sample.
5.3 Advanced Applications
The Cubis Balance includes 18 built-in applications customizable for complex lab weighing tasks. Access these applications through the touchscreen menu. Examples gụnyere:
- Ngbanwe nke otu: Change between various weighing units (g, kg, ct, lb, oz, ozt, grain, dwt, mg, parts per pound, Austrian carat, Newton, lb:oz, microgram).
- SQmin Function: For minimum initial weight according to USP standards.
- Mkpebi njupụta: Calculate the density of samples.
- Nhazi: For multi-component weighing processes.
- Nguko: Determine the number of pieces based on a reference weight.
- Checkweighing: Verify if a sample's weight falls within a defined tolerance range.
- Ọnụọgụ: Perform statistical analysis on a series of weighings.
5.4 nhazi nhazi
Regular calibration is crucial for maintaining accuracy.
- isoCAL (Internal Calibration): The balance automatically performs internal calibration based on temperature and time changes. This function can also be manually initiated via the menu.
- Nhazi nke mpụga: The balance supports calibration using external weights. Refer to the on-screen prompts or the detailed menu instructions for the procedure.
5.5 Data Interface
The balance offers multiple interfaces for data management:
- Ọdụ ụgbọ mmiri USB: For connecting to a computer (Windows OS) for data transfer.
- Ọdụ ụgbọ mmiri RS-232C: For connecting peripheral devices.
- Njikọ Ethernet: For network integration.
- Onye na-agụ kaadị SD: For importing and exporting data.
6. Nlekọta
6.1 Nhicha
To clean the balance, disconnect it from the power supply. Use a soft, damp cloth with a mild detergent. Do not use abrasive cleaners or solvents. Ensure no liquids enter the balance housing. The weighing pan can be removed for separate cleaning.
6.2 Nlekọta n'ozuzu
Protect the balance from dust and debris when not in use. Avoid placing heavy objects on the weighing pan when the balance is off. The balance is IP54 certified, providing protection against dust and water splashes from all directions.
7. Nchọpụta nsogbu
If you encounter issues with your balance, consider the following common solutions:
- Ọgụgụ na-ezighi ezi: Check if the balance is level. Perform an isoCAL or external calibration. Ensure the environment is stable and free from drafts or vibrations.
- Ngosipụta anaghị arụ ọrụ: Verify the power connection. Ensure the power supply is functioning correctly.
- Balance Not Responding: Try restarting the balance by disconnecting and reconnecting the power.
- Ozi mperi: Refer to the on-screen error codes or the detailed product documentation for specific error interpretations and solutions.
8. Nkọwapụta
| Oke | Uru |
|---|---|
| Capacity/Readability | 2,200g / 10mg (0.01g) |
| Linearity/Repeatability | 20mg / 7mg |
| Opekempe Sample Weight (USP) | 8.2g (typical) |
| Nkeji na-atụ atụ | gram, kilogram, carat, pound, ounce, troy ounce, grain, pennyweight, milligram, parts per pound, Austrian carat, Newton, pound:ounce, microgram |
| Ngosipụta | 5.7" high-resolution color TFT touchscreen |
| Built-in Applications | Unit conversion, SQmin function, isoCAL, individual identifiers, density determination, statistics, calculations, averaging, formulation, weighing in percent, time-controlled functions, totalizing, DKD measurement uncertainty, second tare memory, counting, checkweighing, alibi memory, audit trail (18 total) |
| Ọnụ ụzọ | USB, RS-232C, Ethernet, SD card reader |
| Atụmatụ nchekwa | User passwords, fastening point for anti-theft locking device |
| Oke okpomoku na-arụ ọrụ | 5 to 40 degrees C at 80% RH (up to 31 degrees C), decreasing linearly to 50% RH at 40 degrees C |
| nnabata | ISO, FDA, USP, GxP; IP54 |
| Ike | 100-240V, 50-60Hz (120V line cord included) |
| Weighing Pan (Stainless Steel) | 206 x 206mm (W x D) |
| Ibu Ibu | 20 pound |
| Ihe onwunwe | Stainless Steel (weighing pan) |
9. Akwụkwọ ikike na nkwado