Weintek eMT3070A1WK

MT8100iE Weintek 10.2" Graphic HMI User Manual

Model: eMT3070A1WK

1. Okwu mmalite

The Weintek MT8100iE is a 10.2-inch Human Machine Interface (HMI) designed for industrial automation applications. It features an 800 x 480 TFT industrial-grade LCD and is built to fully support major PLCs such as Rockwell, Siemens, Mitsubishi, and Omron. This manual provides essential information for the proper installation, operation, and maintenance of your MT8100iE HMI.

2. Ozi nchekwa

Please read and understand all safety instructions before operating the device. Failure to comply may result in injury or damage to the equipment.

  • Hụ na ewepụla ọkụ eletrik tupu ị rụọ ọrụ nrụnye ma ọ bụ ndozi ọ bụla.
  • Naanị ndị ọrụ tozuru etozu kwesịrị ịwụnye ma nyekwa akụrụngwa a ọrụ.
  • Do not expose the device to excessive moisture, dust, or extreme temperatures.
  • Verify correct wiring and connections to prevent electrical hazards.
  • The front panel is NEMA4/IP65 compliant, but ensure proper sealing during installation to maintain this rating.

3. Ihe ngwugwu

Chọpụta na ihe niile dị na ngwugwu:

  • MT8100iE HMI Unit
  • Ihe nkwado ndị a na-etinye (4x)
  • Njikọ ọkụ
  • Akwụkwọ ntuziaka (akwụkwọ a)
  • CD-ROM with EasyBuilder Pro Software (or download link)

4. Ngwaahịa gafereview

Familiarize yourself with the components and interfaces of the MT8100iE HMI.

4.1 N'ihu View

N'ihu view of the Weintek MT8100iE HMI displaying an industrial boiler control system interface.

Foto 4.1: N'ihu view of the MT8100iE HMI, showing the 10.2-inch TFT LCD touchscreen and the power indicator LED at the top left.

4.2 Akụkụ View

Akụkụ profile of the Weintek MT8100iE HMI, showing its slim design.

Ọgụgụ 4.2: Akụkụ profile of the MT8100iE, illustrating its compact form factor suitable for panel mounting.

4.3 N'azụ View

N'azụ view of the Weintek MT8100iE HMI, showing mounting points, fuse holder, and reset button.

Ọgụgụ 4.3: N'azụ view of the MT8100iE, highlighting the mounting holes for panel installation, the fuse holder for power protection, and the system reset button.

4.4 ọdụ ụgbọ mmiri

N'okpuru view of the Weintek MT8100iE HMI showing USB, Ethernet, and serial communication ports.

Onyonyo 4.4: N'okpuru view of the MT8100iE, detailing the various communication ports including USB, Ethernet, COM1 (RS-232), and COM2 (RS-485 2W/4W).

5. Nhazi

5.1 Panel arịọnụ

  1. Cut an opening in the control panel according to the dimensions provided in the installation guide (refer to the separate installation template for precise measurements).
  2. Insert the MT8100iE HMI into the cutout from the front.
  3. From the rear of the panel, insert the four mounting brackets into the slots on the HMI unit.
  4. Tighten the screws on the mounting brackets evenly until the HMI is securely fastened to the panel. Do not overtighten.

5.2 Njikọ ike

  • Connect a 24V DC power supply to the power input terminal block on the rear of the HMI.
  • Ensure correct polarity (+ and -).
  • Secure the connection firmly.

5.3 Njikọ njikọ

  • Ọdụ ụgbọ mmiri Oghere Usoro: Use the COM1 (RS-232) and COM2 (RS-485 2W/4W) ports to connect to PLCs or other serial devices. Refer to your PLC's documentation for specific wiring diagrams.
  • Njikọ Ethernet: Connect an Ethernet cable to the RJ45 port for network communication with PLCs or for remote access.
  • ọdụ ụgbọ mmiri USB: Use the USB host ports for connecting USB flash drives for project transfers or other peripherals.

6. Ntuziaka ọrụ

6.1 Na-agbanye ike

Once all connections are secure, apply power to the HMI. The power indicator LED will illuminate, and the HMI will boot up, displaying the configured project.

6.2 Project Download

To load a new project or update an existing one:

  1. Create or modify your HMI project using the EasyBuilder Pro software on a PC.
  2. Connect the PC to the HMI via Ethernet or USB.
  3. In EasyBuilder Pro, use the 'Download' function to transfer the project to the HMI.
  4. The HMI will restart with the new project loaded.

6.3 Touchscreen arụ ọrụ

The MT8100iE features a resistive touchscreen. Use your finger or a non-sharp stylus to interact with the on-screen elements such as buttons, input fields, and displays.

6.4 PLC Communication

The HMI is designed to communicate with various PLCs. Ensure the communication settings (protocol, baud rate, station ID, etc.) configured in your EasyBuilder Pro project match those of your connected PLC.

7. Nlekọta

Regular maintenance ensures optimal performance and longevity of your HMI.

  • Nhicha: Jiri nwayọọ, damp cloth to clean the screen and casing. Do not use abrasive cleaners or solvents. Ensure no liquid enters the device.
  • Mmelite femụwe: Periodically check the Weintek website for firmware updates to ensure your HMI has the latest features and bug fixes.
  • Ndochi fiusi: If the HMI does not power on, check the fuse located on the rear panel. Replace it with a fuse of the same type and rating if necessary. Always disconnect power before replacing the fuse.
  • Ọnọdụ gburugburu: Gbaa mbọ hụ na gburugburu ebe ọrụ ka dị n'ime oke okpomọkụ na iru mmiri akọwapụtara iji gbochie mmebi.

8. Nchọpụta nsogbu

Akụkụ a na-enye azịza maka nsogbu nkịtị ị nwere ike izute.

NsogbuIhe nwere ike imeNgwọta
HMI does not power on.No power supply, incorrect wiring, blown fuse.Check power connection, verify wiring polarity, replace fuse if blown.
Touchscreen is unresponsive.Screen calibration issue, hardware fault.Perform screen calibration (refer to EasyBuilder Pro documentation), contact support if issue persists.
Cannot communicate with PLC.Incorrect communication settings, wrong cable, PLC offline.Verify communication protocol, baud rate, and station ID in EasyBuilder Pro. Check cable connections. Ensure PLC is powered on and running.
Project download fails.Network issue, incorrect IP address, firewall blocking.Check network cable, verify HMI and PC IP addresses are in the same subnet. Temporarily disable firewalls for testing.

9. Nkọwapụta

NjirimaraNkọwa
Nọmba nlereanyaeMT3070A1WK
Nha ihuenyo10.2 sentimita asatọ
Mkpebi800 x480
Akụkụ akụkụ1.66:1
Ihu Ihuenyokenkowaputa
Ebe nchekwaEbe nchekwa Flash 128 MB arụnyere n'ime ya
Ezigbo oge elekere (RTC)Ee
Ntụle ihu ihuNEMA4/IP65 Compliant
Ọdụ ụgbọ mmiri SerialCOM1 RS-232 / COM2 RS-485 (2W/4W)
Ozi emailStatus e-Mail notification feature

10. Akwụkwọ ikike na nkwado

Weintek products are manufactured to high quality standards. For warranty information and technical support, please refer to the official Weintek website or contact your authorized distributor. Keep your purchase receipt as proof of purchase for warranty claims.

For software downloads, drivers, and additional resources, visit the official Weintek support portal.

Akwụkwọ ndị emetụtara - eMT3070A1WK

Tupuview WEINTEK cMT3106XM Handheld HMI Datasheet | Specifications & Features
Detailed datasheet for the WEINTEK cMT3106XM 10.1-inch WVA Handheld HMI. Explore features, technical specifications, environmental ratings, and ordering information.
Tupuview Weintek cMT2108X2 10.1-inch TFT HMI - Akwụkwọ data na nkọwapụta.
Mpempe akwụkwọ ozi zuru ezu maka Weintek cMT2108X2, TFT HMI 10.1 inch nwere mkpebi 1024 × 600, ebe nchekwa 4GB, yana njirimara ọkwa ụlọ ọrụ. Gụnyere nkọwapụta, akụkụ na ozi ịtụ.
Tupuview WEINTEK MODBUS RTU, RTU over TCP PLC Connection Guide
Technical guide from WEINTEK detailing the configuration and connection of HMIs using MODBUS RTU and RTU over TCP protocols. Covers HMI and PLC settings, device addressing, wiring diagrams, and Modbus RTU function codes for industrial automation.
Tupuview Weintek cMT-G02X Series HMI Installation Instructions
Detailed installation instructions for the Weintek cMT-G02X Series HMI, covering environment setup, power and communication connections, software configuration, safety precautions, and warranty information.
Tupuview Weintek cMT-CTRL01 Series HMI Installation Guide
Installation instructions for the Weintek cMT-CTRL01 Series HMI. This guide covers environmental setup, unpacking, physical installation, power and communication connections, system settings, LED indicators, reset procedures, battery replacement, and warranty information. Designed for industrial automation professionals.
Tupuview cMT-G05X Series Installation Instructions | Weintek HMI
Official installation instructions for the Weintek cMT-G05X Series HMI. Covers setup, environment, power connections, system settings, communication, software, and warranty.