1. Okwu mmalite
The Inogen One G3 External Battery Charger (Model BA-303) is designed to provide a convenient and efficient method for charging Inogen One G3 standard and extended batteries independently of the Inogen One G3 portable oxygen concentrator. This manual provides essential information for the safe and effective use of your charger.

Image: The Inogen One G3 External Battery Charger with an Inogen One G3 battery inserted, ready for charging.
2. Ozi nchekwa
Please read all safety instructions before using the Inogen One G3 External Battery Charger. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Use only with Inogen One G3 standard (BA-300) and extended (BA-316) batteries.
- Ekwela ka chaja ahụ banye na mmiri ma ọ bụ oke mmiri.
- Anwala ịkwasa ma ọ bụ gbanwee chaja.
- Ensure the charger is connected to a compatible electrical outlet (100-240V AC, 50-60Hz).
- Debe chaja na ebe okpomọkụ na ìhè anyanwụ kpọmkwem.
- If the charger or power cord is damaged, discontinue use immediately and contact customer support.
Nkwusa iwu: Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition. This product is an accessory for a medical device.
3. Ihe ngwugwu
Chọpụta na ihe niile dị na ngwugwu:
- Inogen One G3 External Battery Charger (Model BA-303)
- eriri ntinye AC
4. Ndakọrịta
This external battery charger is specifically designed for use with Inogen One G3 batteries. It supports both the standard (BA-300) and extended (BA-316) Inogen One G3 battery models.

Image: An accessory compatibility chart showing the Inogen One G3 External Battery Charger (BA-303) is compatible with Inogen One G3 Standard (BA-300) and Extended (BA-316) batteries.
5. Nhazi ntuziaka
Follow these steps to set up your Inogen One G3 External Battery Charger:
- Jikọọ ike AC: Plug the AC input cord into an electrical outlet.

Image: Step 1 of the charging process, showing the AC power cord being plugged into a wall outlet.
- Jikọọ na chaja: Plug the other end of the AC input cord into the designated port on the external battery charger.

Image: Step 2 of the charging process, illustrating the AC power cord connected to the external battery charger.
- Fanye batrị: Slide your Inogen G3 battery onto the charger until it clicks and locks into place. Ensure it is seated correctly.

Image: Step 3 of the charging process, showing an Inogen G3 battery being slid onto the charger until it locks.
6. Ntuziaka ọrụ
Once the charger is set up and a battery is inserted, the charging process will begin automatically.
Ngosipụta Nchaji
- Ìhè uhie siri ike: When the battery is correctly positioned on the charger, a solid red light will illuminate, indicating that the battery is actively charging.

Image: Step 4 of the charging process, showing the charger with a solid red light, indicating the battery is charging.
- Ọkụ ndụ ndụ: When the green light illuminates, the battery is fully charged and ready for use.

Image: Step 5 of the charging process, showing the charger with a green light, indicating the battery is fully charged.
Oge nchaji
Approximate charging times are as follows:
- Standard Inogen One G3 Battery: Up to 5 hours
- Extended Inogen One G3 Battery: Up to 8 hours

Image: The Inogen One G3 External Battery Charger with a battery, illustrating the approximate charging times for standard and extended batteries.
For continuous use, consider having multiple batteries and an additional external charger to ensure batteries are always ready.
7. Nlekọta
The Inogen One G3 External Battery Charger requires minimal maintenance.
- Keep the charger clean and free from dust. Wipe with a dry, soft cloth.
- Ejila ihe nhicha mmiri ma ọ bụ ihe ndị na-eme ka ihe dị nro mee ihe.
- Chekwaa chaja n'ebe dị jụụ, kpọrọ nkụ mgbe anaghị eji ya.
- Inspect the power cord regularly for any signs of damage.
8. Nchọpụta nsogbu
Ọ bụrụ na ị hụ nsogbu na chaja gị, lee nsogbu na ngwọta ndị a na-ahụkarị:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Charger light not illuminating | No power to charger, battery not inserted correctly, or charger malfunction. |
|
| Ọkụ na-acha uhie uhie na-egbu maramara | Error during charging process. |
|
| Batrị anaghị achacha cha cha | Battery issue or charger malfunction. |
|
9. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nọmba nlereanya | BA-303 |
| Ndakọrịta | Inogen One G3 Standard (BA-300) and Extended (BA-316) Batteries |
| Ntinye Voltage | 100-240V AC, 50-60Hz |
| Mmepụta Voltage | 15 volts |
| Akụkụ (W x L x H) | 3.3 inch x 2.75 inch x 1 inch. |
| Ibu | 0.12 n'arọ. (ihe dị ka.) |
| Standard Battery Charge Time | Ruo awa iri abụọ |
| Extended Battery Charge Time | Ruo awa iri abụọ |
10. Akwụkwọ ikike na nkwado
For warranty information and customer support, please refer to the documentation provided with your original Inogen One G3 portable oxygen concentrator or visit the official Inogen websaịtị.