1. Okwu mmalite
The AL-KO HW 6000 FMS Premium Domestic Water Pump is a high-performance system designed for reliable water supply and pressure boosting. It is ideal for drawing rainwater from wells, cisterns, and rainwater tanks, and for enhancing water pressure in domestic, yard, and garden applications. This manual provides essential information for safe installation, operation, and maintenance of your pump.
2. Ozi nchekwa
Na-edebe nchekwa nchekwa ndị a mgbe niile iji gbochie mmerụ ahụ na mmebi nke akụrụngwa:
- Nchekwa Eletriki: Ensure the power supply matches the pump's specifications (230V). Always disconnect power before performing any maintenance or installation. Use a ground fault circuit interrupter (GFCI) for outdoor use.
- Nchekwa mmiri: Do not pump flammable or corrosive liquids. Ensure all connections are watertight to prevent leaks and electrical hazards.
- Nwụnye: The pump must be installed in a location protected from rain and splashes. Ensure stable placement on a level surface.
- Ọrụ: Never operate the pump dry. The integrated dry-run protection helps, but manual checks are crucial during initial setup.
- Ụmụaka na anụ ụlọ: Debe ụmụaka na anụ ụlọ ka ha ghara ịbanye na pamụpụ a na-arụ ọrụ.
- Nlekọta: Only perform maintenance tasks described in this manual. For complex repairs, contact qualified service personnel.
3. Ntọala na nwụnye
Proper installation is crucial for the optimal performance and longevity of your AL-KO HW 6000 FMS Premium pump.
3.1 Mwepu na nyocha
Carefully remove the pump from its packaging. Inspect for any signs of damage during transit. Ensure all components listed in the packing contents are present, including the instruction manual, corner connection, and filter wrench.
3.2 Ntinye
Place the pump on a firm, level surface. It must be protected from direct weather exposure (rain, splashes). Ensure adequate ventilation around the unit.

Ọgụgụ 1: Ọpụample installation of the AL-KO HW 6000 FMS Premium pump in a utility room, demonstrating connections to the household water system.
3.3 Njikọ eriri mmiri
- Ahịrị mmiri: Connect a robust, non-kinking suction hose to the pump's suction inlet. Ensure the suction line is completely airtight to prevent air ingress, which can impair pump performance. For optimal self-priming, the suction height should not exceed 8 meters.
- Pressure Line: Connect the pressure line to the pump's outlet. The included corner connection and check valve should be used to prevent backflow and maintain pressure.
- Ịmepụta mgbapụta ahụ: Before initial operation, fill the pump housing completely with water through the designated filling opening until no more air bubbles emerge. This is essential for self-priming.
3.4 Njikọ eletrik
Connect the pump to a properly grounded 230V power outlet. Ensure the electrical circuit is protected by a residual current device (RCD/GFCI) for safety, especially in damp environments or outdoor installations.
4. Ọrụ
The AL-KO HW 6000 FMS Premium pump features intelligent electronic control for efficient and safe operation.
4.1 Ịmalite mgbapụta
- Ensure the pump is properly primed (see Section 3.3).
- Connect the pump to the power supply. The pump will perform a self-check.
- The Flow-Measurement System (FMS) display will show the current operating status.
- Open a water tap in your system. The pump will automatically start to deliver water.

Figure 2: The control panel of the AL-KO HW 6000 FMS Premium, highlighting the FMS display and mode selection buttons.
4.2 Eco Ọnọdụ
To save energy, switch the pump to Eco mode. This mode can reduce energy consumption by approximately 15% compared to normal operation. Refer to the pump's display and controls for activating Eco mode.
4.3 Dry-Run Protection
The integrated dry-run protection system automatically shuts off the pump if no water is detected in the suction line, preventing damage. If the pump stops due to dry-run protection, check your water source and suction line for issues before restarting.
5. Nlekọta
Regular maintenance ensures the long-term performance and reliability of your pump.
5.1 Nhicha Nzacha Tupu
The pump is equipped with a large, easy-to-clean pre-filter that protects the pump's interior from dirt and debris. Regularly check and clean the filter, especially if you notice a decrease in pump performance.
- Kwụpụ mgbapụta na ọkụ ọkụ.
- Close any valves on the suction and pressure lines.
- Use the provided filter wrench to carefully open the filter housing.
- Remove the filter element and rinse it thoroughly under clean running water.
- Inspect the filter element for damage and replace if necessary.
- Reinsert the clean filter element and securely close the filter housing using the wrench.
- Reconnect power and prime the pump if necessary before restarting.

Figure 3: Using the filter wrench to access and clean the pre-filter.
5.2 Oge oyi
If the pump is exposed to freezing temperatures, it must be drained completely to prevent frost damage. Disconnect all water lines and open the drain plug to allow all water to escape. Store the pump in a frost-free location.
6. Nchọpụta nsogbu
This section provides solutions to common issues you might encounter with your AL-KO HW 6000 FMS Premium pump.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Pump does not start or deliver water. | No power supply; pump not primed; air in suction line; dry-run protection activated; clogged filter. | Check power connection; prime the pump; check suction line for leaks; check water source; clean pre-filter. |
| Reduced water flow or pressure. | Clogged pre-filter; air in suction line; low water level in source; partially closed valves. | Clean pre-filter; check suction line for leaks; ensure adequate water supply; open all valves fully. |
| Pump runs continuously or cycles frequently. | Leak in pressure system; check valve faulty; insufficient air in pressure tank. | Inspect all connections for leaks; check/replace check valve; ensure proper air charge in the pressure tank (refer to specific instructions for pressure tank maintenance). |
| Mkpọtụ na-adịghị ahụkebe n'oge arụ ọrụ. | Air in pump/lines; foreign object in pump; motor bearing issue. | Bleed air from the system; disconnect power and inspect pump impeller for obstructions (if safe to do so); if noise persists, contact service. |
If you are unable to resolve the issue using the troubleshooting guide, please contact AL-KO customer support or a qualified service technician.
7. Nka na ụzụ nkọwa
| Njirimara | Nkọwapụta |
|---|---|
| Nlereanya | HW 6000 FMS Premium |
| Nọmba akụkụ | 112852 |
| Onye nrụpụta | AL-KO |
| Ike moto | 1400 W |
| Oke. Ọnụego mgbaba | 6000 lita kwa elekere |
| Oke. Isi nnyefe | 60 mita |
| Oke. Isi Elu | 8 Meters (typical for self-priming pumps) |
| Pressure Tank Volume | Lita 20 (Ígwè anaghị agba nchara) |
| Voltage | 230.01 Volt |
| Ọkwa mkpọtụ | 73 dB |
| Akụkụ (L x W x H) | 51.6 x 28.4 x 64.7 cm |
| Ibu | 20 n'arọ |
| Ihe onwunwe | Igwe anaghị agba nchara |
| Ngwa gụnyere | Instruction manual, corner connection, filter wrench |
8. Akwụkwọ ikike na nkwado
AL-KO provides a manufacturer's warranty for this product. Please refer to the warranty card included with your purchase or visit the official AL-KO websaịtị maka nkọwa zuru oke usoro na ọnọdụ nke akọwapụtara mpaghara gị.
For technical assistance, spare parts, or service inquiries, please contact AL-KO customer support:
- AL-KO Official Websaịtị: www.al-ko.com (Lelee maka ozi kọntaktị mpaghara)
- Ndị ọrụ nlekọta ndị ahịa: Refer to your purchase documentation or the AL-KO website for regional contact numbers and email addresses.
When contacting support, please have your model number (HW 6000 FMS Premium) and part number (112852) ready.