TTI BS407

TTI BS407 Precision Milli/Micro Ohmmeter User Manual

Ụdị: BS407

Ngwaahịa gafereview

The TTI BS407 is a high-precision digital microohmmeter designed for accurate resistance measurements from 1 micro-ohm up to 20 kilo-ohms. It features a 4-wire connection method to eliminate lead resistance errors, ensuring high accuracy for critical applications. This instrument is suitable for a wide range of industrial and scientific testing requirements.

N'ihu view of the TTI BS407 Precision Milli/Micro Ohmmeter showing the display, controls, and terminals.

The image displays the front panel of the TTI BS407 Precision Milli/Micro Ohmmeter. Key features visible include the digital display, the 'ZERO ADJUST' knob, buttons for 'Operate', 'Set Zero', '20mV Clamp', and 'Polarity', and the input terminals for 'SENSE' and 'FORCE' connections. Below the display, various resistance ranges (µΩ, mΩ, Ω, kΩ) and corresponding force currents (250mA, 50mA, 10mA, 5mA, 500µA, 50µA, 50µA, 10µA) are indicated.

Ntọala na Njikọ

Before operating the BS407, ensure it is placed on a stable, level surface and connected to a suitable power source. The instrument uses a 4-wire connection method for precise resistance measurements.

Njikọ ike:

4-Wire Measurement Connection:

The 4-wire (Kelvin) connection method eliminates the resistance of the test leads from the measurement, providing higher accuracy, especially for low resistance values.

  1. Identify the 'SENSE' terminals (red and black) and 'FORCE' terminals (red and black) on the front panel.
  2. Connect the 'FORCE' leads to the points on the component or circuit where the test current will be injected. The red 'FORCE' terminal is positive (+), and the black 'FORCE' terminal is negative (-).
  3. Connect the 'SENSE' leads as close as possible to the points where the voltage drop across the component is to be measured. The red 'SENSE' terminal corresponds to the positive voltage sense, and the black 'SENSE' terminal to the negative voltage uche.
  4. Ensure good contact between the test leads and the component under test to prevent measurement errors.

Ntuziaka ọrụ

This section details the steps for performing resistance measurements using the BS407.

Basic Measurement Procedure:

  1. Ike Na: Flip the 'On/Off' switch on the front panel to the 'On' position. The display will illuminate.
  2. Ndozi efu: Before connecting the test leads to the component, ensure the leads are open-circuited (not touching anything). Use the 'ZERO ADJUST' knob to fine-tune the display to read zero. For more precise zeroing, press the 'Set Zero' button.
  3. Select Range and Force Current: The BS407 automatically selects the appropriate range. However, you can observe the selected range (µΩ, mΩ, Ω, kΩ) and the corresponding force current (e.g., 250mA, 50mA, 10mA, 5mA, 500µA, 50µA, 10µA) indicated by the LEDs below the display. The instrument will apply the necessary force current for the selected range.
  4. Jikọọ Ndị Nnwale: Connect the 4-wire test leads to the component as described in the "Setup and Connections" section.
  5. Gụọ nha: The resistance value will be displayed on the large digital readout.
  6. Polarity: If measuring components with inherent polarity or when observing voltage drop, the 'Polarity' button can be used to reverse the current direction if needed, or to observe the polarity of the measured voltage.
  7. 20mV Clamp: The '20mV Clamp' function limits the voltage across the device under test to 20mV, which is useful for testing sensitive components like thermistors or fuses without causing self-heating errors.
  8. Operate Button: The 'Operate' button initiates or holds a measurement cycle.

Understanding Display Indicators:

Nlekọta

Proper maintenance ensures the longevity and accuracy of your TTI BS407.

Nchọpụta nsogbu

Akụkụ a na-enye azịza maka nsogbu nkịtị ị nwere ike izute.

NsogbuIhe nwere ike imeNgwọta
Ngwa anaghị arụ ọrụ.No power supply; faulty power cord; internal fuse blown.Check power cord connection and wall outlet. Try a different power cord. If issue persists, contact service.
Inaccurate readings or fluctuating display.Poor lead connection; incorrect zero adjustment; external interference; damaged test leads.Ensure leads are securely connected. Perform zero adjustment. Move instrument away from strong electromagnetic fields. Inspect and replace damaged leads.
"OVERLOAD" or "OL" displayed.Resistance value exceeds selected range; open circuit.Ensure the component is connected. The instrument should auto-range, but if not, check the component's expected resistance.

Nkọwapụta

OkeUru
Oke Nledo Nguzogide1µohm to 20kohm
Mkpebi1µohm
Izi ezi± 0.1%
Nwale Ugbu aUp to 250mA (range dependent)
Njikọ waya4-Wire (Kelvin)
External Height88mm
Obosara Mpụga220mm
External Depth230mm
Ibu1.3kg (Instrument only), 6.02 Pounds (Shipping weight)
Isi Iyi IkeIgwe ọkụ eletrik
Nọmba nlereanyaBS407
Onye nrụpụtaAIM-TTI Instruments
RoHS kwadoroEe

Akwụkwọ ikike na nkwado

For information regarding product warranty, technical support, or service, please contact AIM-TTI Instruments directly or refer to their official websaịtị. Debe nnata nzụta gị dị ka ihe akaebe nke ịzụrụ maka nkwupụta ikike.

Onye nrụpụta: AIM-TTI Instruments

Websaịtị: www.aimtti.com (Note: This is a general manufacturer website, specific support details may vary.)

Akwụkwọ ndị emetụtara - BS407

Tupuview TTI TSC-100RA Multiband Scanning Receiver Instruction Manual
This manual provides comprehensive instructions for operating the TTI TSC-100RA Multiband Scanning Receiver, covering setup, controls, general operation, frequency scanning, memory management, and troubleshooting.
Tupuview Akwụkwọ ntuziaka ntuziaka TTi TCB-550evo 4W Mobile CB Transceiver
Comprehensive instruction manual for the TTi TCB-550evo 4W Mobile CB Transceiver, covering installation, operation, specifications, safety, and troubleshooting.
Tupuview TTI 2026 Benefits Summary: Health, Wealth, and Life
A keukwu overview of TTI's 2026 employee benefits, detailing medical, dental, vision, prescription drug coverage, mental health and work-life services, financial benefits like HSAs, FSAs, and 401(k) plans, disability and life insurance options, costs, and IRS plan limits.
Tupuview TTI 2026 Employee Benefits Summary: Health, Wealth, and Life
Zuru okeview of TTI's 2026 employee benefits, including medical, dental, vision, financial planning, life insurance, disability, and more. Details on costs, coverage, and enrollment.
Tupuview 創科實業 2021年報:電動工具與戶外設備的增長動力
創科實業有限公司的2021年報,詳細介紹了公司在電動工具、戶外園藝工具、地板護理及清潔產品領域的強勁財務表現和戰略發展。報告強調了MILWAUKEE和RYOBI等品牌的增長,以及對充電式技術和可可技術和可可。
Tupuview Connecting TTi Instruments Over LAN with NI-VISA
This application note provides step-by-step instructions on how to establish a LAN/TCP-IP connection to TTi instruments using National Instruments' NI-VISA software, enabling communication via raw sockets.