The Rectorseal Aspen Mini Lime Condensate Pump Kit is designed for efficient removal of condensed water from ductless mini-split AC systems. This compact unit integrates both the pump and reservoir, facilitating flexible installation options. It is engineered for quiet operation and easy maintenance, making it an ideal solution for managing condensate in various HVAC applications.

Rectorseal Aspen Mini Lime Condensate Pump with Slimline Cover components

Image: Components of the Aspen Mini Lime Condensate Pump Kit, including the pump unit, tubing, and slimline cover.

Ozi nchekwa

Always disconnect power before installing or servicing the pump. Ensure all electrical connections comply with local codes and regulations. This device operates with electrical components and water; improper installation can lead to electric shock or fire. Do not operate the pump if it is damaged or if any wires are frayed. Keep out of reach of children.

Ntọala na nwụnye

The Aspen Mini Lime pump is designed for easy installation, either to the left or right of the evaporator unit. It integrates the pump and reservoir into a single unit, eliminating the need for separate connecting tubes or wires for the reservoir.

Ngwa achọrọ:

Nzọụkwụ nwụnye:

  1. Kwadebe Mpaghara: Ensure the area around the mini-split evaporator is clean and accessible. Identify the condensate drain outlet.
  2. Ịkwanye mgbapụta ahụ: The pump can be mounted directly onto the reservoir. Position the pump unit in a location that allows for minimal suction lift from the evaporator's condensate tray. The slimline cover is designed to conceal the unit and line set.
  3. Jikọọ eriri mmiri mmiri: Connect the condensate drain line from the evaporator coil to the inlet of the pump's reservoir. Ensure a secure, watertight connection.
  4. Connect Discharge Line: Attach the discharge tubing from the pump's outlet to a suitable drain point, ensuring a continuous downward slope to prevent water traps. The pump can lift water up to 33 feet vertically.
  5. Njikọ eletrik:
    • Connect the pump's power supply wires to a suitable 100-250V AC power source. Refer to the wiring diagram provided with the product for specific connections.
    • Safety Switch (NC Dry Contacts): Connect the 3A NC (Normally Closed) dry contacts to the AC unit's control circuit. This safety switch will shut down the AC unit if the pump reservoir reaches a high water level, preventing overflow. These contacts are rated at 5A inductive at 230V AC.
  6. Ngwa ndị echedoro: Secure all tubing and electrical wiring using appropriate fasteners or clips. Install the slimline cover to conceal the line set and pump unit for a clean finish.
  7. Ọrụ nnwale: After installation, power on the AC unit and observe the condensate drainage. Ensure the pump activates when the reservoir fills and effectively discharges water. Check for any leaks.

Ntuziaka ọrụ

The Aspen Mini Lime pump operates automatically. When condensate water from the AC unit fills the pump's reservoir to a predetermined level, the internal float switch activates the pump. The pump then discharges the water through the drain line until the reservoir level drops, at which point the pump deactivates.

Nlekọta

Regular maintenance ensures optimal performance and longevity of your condensate pump. It is recommended to perform maintenance at least once a year, or more frequently in dusty environments.

Cleaning the Reservoir and Filter:

  1. Kwụpụ ike: Always turn off the power to the AC unit and the condensate pump before performing any maintenance.
  2. Access Reservoir: The transparent reservoir easily clips off for quick access. Carefully remove the elbow cover and detach the reservoir.
  3. Ngwa dị ọcha: Remove any debris, sludge, or algae buildup from the reservoir, float switch, and filter screen. Use warm water and a mild detergent. Avoid abrasive cleaners.
  4. Nyochaa Tubing: Check the inlet and outlet tubing for any blockages or kinks. Clear any obstructions.
  5. Gbakọtaghachi: Reattach the reservoir and elbow cover securely. Ensure all connections are tight.
  6. Nwalee: Restore power and verify proper operation by observing the pump's cycle.

Nchọpụta nsogbu

If your Aspen Mini Lime pump is not functioning as expected, refer to the following common issues and solutions:

NsogbuIhe nwere ike imeNgwọta
Mgbapu anaghị agba ọsọNo power; Clogged reservoir/float; Safety switch activated; Motor failureCheck power supply; Clean reservoir and float; Check safety switch wiring; Contact qualified technician
Mgbapụta ọkụ na-aga n'ihuFloat stuck; Check valve faulty; Leak in discharge line; Excessive condensate productionClean float; Inspect/replace check valve; Check for leaks; Verify AC unit size/humidity levels
Water overflow from reservoirPump not running (see above); Discharge line blocked/kinked; Pump undersizedAddress pump not running; Clear discharge line; Ensure pump capacity matches AC unit BTU/hr
Oke mkpọtụAir in pump; Pump not securely mounted; Debris in pumpAllow air to purge; Secure pump mounting; Clean pump/reservoir

For issues not listed or if solutions do not resolve the problem, contact Rectorseal customer support or a qualified HVAC technician.

Nkọwapụta

NjirimaraNkọwa
Nlereanya83849 (Aspen Mini Lime)
VoltageAC AC 100-250V
Wattage16 watt
Oke. IkeRuo 54,600 BTU/awa
Flow Rate (Zero Head)2.9-3.2 GPH (Gallons Per Hour)
Flow Rate (33ft Head)1.3-1.5 GPH (Gallons Per Hour)
Ọkwa ụda25.5dB(A)
Kọntaktị nchekwa3A NC dry contacts rated @ 5A inductive at 230V AC
Lineset Elbow Casing NhaH-5 1/4" x W-5 1/4" x D-2 3/4"
Lineset Duct Casing NhaH-31" x W-5 1/4" x D-2 3/4"
Ihe onwunwePlastic
Ibu Ibu3.5 pound

Ozi akwụkwọ ikike

Rectorseal products are manufactured to high standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Rectorseal websaịtị. Debe ihe akaebe nke ịzụrụ maka akwụkwọ ikike.

Nkwado ndị ahịa

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Rectorseal customer support:

Mgbe ị na-akpọtụrụ nkwado, biko nwee nọmba nlereanya ngwaahịa gị (83849) yana ụbọchị ịzụrụ dị.

Akwụkwọ ndị emetụtara - 83849

Tupuview RectorSeal AquaGuard AG-1200+ Ntuziaka nwụnye
Ntuziaka nrụnye zuru ezu maka RectorSeal AquaGuard AG-1200+ magnetik float mgba ọkụ, gụnyere nchekwa nchekwa, ịrị elu, na eserese wiring maka sistemu HVAC na-emekarị na na-ekwurịta okwu.
Tupuview RectorSeal AquaGuard AG-3180E Installation Instructions and Warranty
Comprehensive installation guide and warranty information for the RectorSeal AquaGuard AG-3180E, a safety switch designed to prevent HVAC system overflow by shutting off the unit when condensate accumulates. Includes safety warnings, wiring diagrams, and warranty terms.
Tupuview RectorSeal AquaGuard AG-1200+ Ntuziaka nwụnye
Nrụnye zuru ezu na ntuziaka wiring maka RectorSeal AquaGuard AG-1200+ magnetik float switch, emebere maka sistemụ HVAC. Gụnyere ịdọ aka ná ntị nchekwa, ntụzịaka nzọụkwụ site n'usoro maka ịgbanye pan na njikọ eletrik na sistemụ HVAC nke ochie na nke na-ekwurịta okwu.
Tupuview RectorSeal AQUAGUARD® 4200E Sensọ mmiri & Ntuziaka nwụnye Port Drain
Ntuziaka nrụnye zuru oke maka RectorSeal AQUAGUARD® 4200E Water Sensor & Drain Port, gụnyere eserese wiring na nkọwa nwụnye pan maka ụdị Titan, Goliath na Goliath Furnace.
Tupuview Espen Pump Kit Wiring Eserese maka GREE 208/230 Volt Evaporators
Ntuziaka wiring na eserese maka ịwụnye nfuli condensate Aspen na GREE 208/230 Volt evaporators. Gụnyere nọmba nlereanya na ndetu nchekwa dị mkpa.
Tupuview Ntuziaka nwụnye RectorSeal AquaGuard AG-1100+ Igwe Ọdụdọ Igwe Ọdụdọ
Nrụnye zuru ezu na ntuziaka wiring maka RectorSeal AquaGuard AG-1100+ magnetik float mgba ọkụ, emebere iji gbochie mmebi sistemu HVAC site na njupụta condensate. Gụnyere ịdọ aka ná ntị nchekwa na eserese.