Simplex LL1011-26D-41

Simplex Kaba LL1011-26D-41 Cylindrical Push Button Lever Lock Instruction Manual

Model: LL1011-26D-41

1. Ngwaahịa gafereview

The Simplex Kaba LL1011-26D-41 is a heavy-duty cylindrical mechanical lock designed for residential or commercial door locking applications where keyless, single access code entry is desired. This lock features a cast front housing, a brass unified trim plate, and a fixed cast lever. It is ADA compliant and offers an economical access control solution.

Simplex Kaba LL1011-26D-41 Cylindrical Push Button Lever Lock, Satin Chrome finish

Image 1.1: Simplex Kaba LL1011-26D-41 Cylindrical Push Button Lever Lock in Satin Chrome finish. This image displays the exterior view of the lock with its push-button keypad and lever handle.

Akụkụ ndị bụ isi:

  • Heavy-duty Construction: Cylindrical lock housing with cast front housing and brass unified trim plate.
  • Ngwaọrụ mkpọchi: Cylindrical Latch with 3-Hour UL/ULC Fire Rating on "A" Labeled Doors.
  • Single Access Code: One easy-to-manage code for all users.
  • Mmemme dị mfe: Lock is easily programmed via keypad without removing it from the door.
  • Inye aka: Factory-handed (Left Hand), not field reversible.
  • ADA kwadoro: Meets accessibility standards.

2. Ngwa gụnyere

Nyochaa na akụrụngwa niile dị tupu ịmalite nrụnye.

  • Lock Assembly (Exterior and Interior)
  • Latch Mechanism
  • Key (for emergency override or specific models)
  • Mounting Hardware (screws, spindle, etc.)
  • Template nwụnye
  • Ntuziaka mmemme

3. Ntọala na nwụnye

Installation of the Simplex Kaba LL1011-26D-41 lock requires basic tools and adherence to the provided template. It is recommended to have a qualified professional perform the installation to ensure proper function and security.

3.1 Nlele Tupu Nwụnye:

  • Ensure the door thickness is between 1-3/8" (35 mm) and 2-1/4" (57 mm).
  • Verify the backset is 2-3/4" (70 mm).
  • Confirm the minimum stile requirement of 5" (127 mm) is met.
  • This lock is factory-handed for Left Hand doors and is not field reversible. Ensure it matches your door's handing.

3.2 Installation Steps (General Guidance):

  1. Kwadebe Ọnụ ụzọ: Use the provided template to mark and drill necessary holes for the lock body and latch mechanism.
  2. Wụnye Latch: Tinye usoro mkpọchi ahụ n'ọnụ ụzọ ma jiri skru mechie ya.
  3. Wụnye Mgbakọ Mpụga: Position the exterior lock assembly (with keypad) onto the door, ensuring the spindle aligns with the latch.
  4. Wụnye Mgbakọ ime ụlọ: Attach the interior lock assembly, connecting it to the exterior assembly and securing it with mounting screws.
  5. Ọrụ nnwale: Before closing the door, test the latch and lever operation.
  6. Set Initial Code: Refer to the separate programming instructions for setting the initial access code.

For detailed, step-by-step installation instructions, please refer to the dedicated installation guide included in your product packaging.

4. Ntuziaka ọrụ

The Simplex Kaba LL1011-26D-41 lock operates using a mechanical push-button keypad and a lever handle.

4.1 Unlocking the Door:

  1. Enter the correct access code by pressing the corresponding buttons on the keypad in sequence.
  2. After entering the code, turn the lever handle to retract the latch and open the door.
  3. The lock will automatically re-lock once the lever is released and the door is closed.

4.2 Locking the Door:

The lock automatically engages when the door is closed. No manual action is required to lock the door from the exterior once the code has been entered and the door opened and closed.

4.3 Changing the Access Code:

The access code can be changed directly on the keypad without removing the lock from the door. This process typically involves a specific sequence of button presses and a programming key or tool. Refer to the separate programming instructions for your specific model for detailed steps on how to change the code.

It is recommended to change the access code periodically for enhanced security.

5. Nlekọta

Proper maintenance ensures the longevity and reliable operation of your Simplex Kaba lock.

  • Nhicha: Jiri nwayọ hichaa elu mpụta, damp cloth. Avoid abrasive cleaners or solvents, which can damage the finish.
  • mmanu mmanu: Periodically apply a small amount of graphite lubricant or a silicone-based spray to the latch bolt and internal mechanisms to ensure smooth operation. Do not use oil-based lubricants as they can attract dirt.
  • Nyocha: Regularly inspect the lock for any signs of wear, loose screws, or damage. Tighten any loose screws immediately.
  • Igodo ahụigodo: Ensure all keypad buttons depress and release smoothly. If a button feels sticky or unresponsive, light lubrication may be applied.

6. Nchọpụta nsogbu

This section addresses common issues you might encounter with your Simplex Kaba LL1011-26D-41 lock.

Nsogbu Ihe nwere ike ime Ngwọta
Lever does not retract latch after code entry. Incorrect code entered, or internal mechanism issue. Re-enter the code carefully. Ensure all buttons are fully depressed. If issue persists, check programming or consult support.
Buttons feel stiff or sticky. Accumulation of dirt or lack of lubrication. Clean buttons and apply a small amount of graphite or silicone lubricant.
Ọnụ ụzọ anaghị akpọchi akpaghị aka. Latch bolt not fully extending, or door alignment issue. Check for obstructions around the latch bolt. Ensure the door closes properly and the strike plate is aligned. Lubricate the latch bolt.
Code change procedure fails. Incorrect programming sequence. Jiri nlezianya review and follow the specific programming instructions provided with your lock.

If you encounter issues not listed here or if solutions do not resolve the problem, please contact Simplex Kaba customer support.

7. Nkọwapụta

  • Ụdị: LL1011-26D-41
  • Akara: Simplex Kaba
  • Ụdị mkpọchi: Cylindrical Mechanical Push Button Lock
  • Mechaa: Satin Chrome (US26D)
  • Ihe: Zinc (Lever), Cast Front Housing
  • Inye aka: Left Hand (Factory-Handed, Not Field Reversible)
  • Mbido: 2-3/4" (70 mm)
  • Ọkpụrụkpụ ọnụ ụzọ: 1-3/8" (35 mm) to 2-1/4" (57 mm)
  • Minimum Stile Requirement: 5" (127 mm)
  • Ọnụọgụ ọkụ: 3-Hour UL/ULC Fire Rating on "A" Labeled Doors
  • Njikwa Type: Pịa bọtịnụ
  • Ibu ihe: Ihe dị ka 9 lbs (4.1 n'arọ)
  • Akụkụ ngwugwu: 10.6 x 10.4 x 8.6 sentimita (26.9 x 26.4 x 21.8 cm)
  • Mba onye si: United States

8. Akwụkwọ ikike na nkwado

For specific warranty information regarding your Simplex Kaba LL1011-26D-41 lock, please refer to the warranty card included with your product or visit the official Simplex Kaba webEbe a na-edebe akwụkwọ ikike. Usoro akwụkwọ ikike na-ekpuchi ntụpọ nrụpụta n'oge ojiji nkịtị.

If you require technical assistance, have questions about installation, programming, or troubleshooting, please contact Simplex Kaba customer support. Contact details can usually be found on the product packaging or the manufacturer's official websaịtị.

Onye nrụpụta: KABA

Akara: Simplex

Akwụkwọ ndị emetụtara - LL1011-26D-41

Tupuview Simplex IDNet/MAPNET II ọdụ ụgbọ oti mkpu ọkụ - Data ngwaahịa
Ozi zuru ezu na Simplex 4099 Series addressable manual fire alert station, dakọtara na IDNet na sistemụ MAPNET II. Ngosipụta, nkọwapụta, nhọrọ ịrịgo, na nhọrọ ngwaahịa maka ụdị dị iche iche, gụnyere otu omume, ime ihe ugboro abụọ (glass na ntugharị), yana nhọrọ GRIP. Dabara na ihe ADA chọrọ yana UL, ULC, FM na CSFM depụtara ya.
Tupuview Simplex 4004 Fire Alarm Control Panel: Installation and Operation Instructions
Comprehensive guide for installing, operating, and programming the Simplex 4004 Fire Alarm Control Panel (FACP), including system overview, requirements, wiring, module descriptions, and troubleshooting.
Tupuview Echiche na Ntuziaka Sistemụ Mkpu Ọkụ nke Simplex 2001-8001
Akwụkwọ ntuziaka teknụzụ zuru ezu na-akọwa echiche, modulu, na nhazi nke Sistemụ Mkpu Ọkụ Simplex 2001-8001, gụnyere ọrụ ndị na-anaghị ada ụda, ụda olu, mkpu nhọrọ, koodu koodu, na ọrụ ndị e ji koodu ukwu rụọ.
Tupuview Simplex 4010 Ọkụ Mkpu: Nrụnye, Ọrụ, na Ntuziaka Mmemme
Ntuziaka zuru oke maka Simplex 4010 Fire Alarm System, mkpuchi mkpuchi, ọrụ, na ntụziaka mmemme. Na-agụnye usoro gafereview, wiring, nhazi, nchoputa, na nchọpụta nsogbu.
Tupuview Simplex 4010ES: Systèmes de commande d'extinction automatique pour gicleurs
Guide technique Simplex 4010ES détaillant les modules de commande pour les systèmes d'extinction automatique par gicleurs, couvrant les modes déluge et préventif, avec spécifications, homologations et schémas de câblage.
Tupuview Simplex 4010 Ọkụ Mkpu: Nrụnye, Ọrụ, na Ntuziaka Mmemme
Ntuziaka zuru oke maka ịwụnye, ịrụ ọrụ, na mmemme nke Simplex 4010 Fire Alarm. Sistemụ kpuchieview, wiring, nhazi, nchoputa, na nchọpụta nsogbu.