FLIR MR77

Ntuziaka Onye Ọrụ nke Mita Mmiri Na-enweghị Mmiri FLIR MR77

Comprehensive instructions for operation and maintenance of your FLIR MR77 Moisture Meter.

1. Okwu mmalite

The FLIR MR77 Pinless Moisture Meter is a professional-grade instrument designed for accurate moisture and environmental measurements. This device combines pinless moisture detection with an external pin probe, relative humidity, and temperature sensing capabilities, making it a versatile tool for various applications.

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your FLIR MR77 meter to ensure optimal performance and longevity.

2. Mwepu na ọdịnaya

Carefully unpack all items from the packaging. Verify that all components are present and undamaged. If any items are missing or damaged, contact your supplier immediately.

Ọdịnaya ngwugwu:

FLIR MR77 Pinless Moisture Meter

Figure 2.1: The FLIR MR77 Pinless Moisture Meter with its integrated sensor and display.

3. Ntọala na Ntinye Batrị

3.1 Ntinye batrị

  1. Chọta ebe batrị dị n'azụ mita ahụ.
  2. Mepee mkpuchi nke batrị batrị.
  3. Insert the included 9V battery, observing correct polarity.
  4. Mechie mkpuchi nke batrị batrị nke ọma.

3.2 Attaching Sensors

The MR77 comes with an integrated pinless sensor and ports for external sensors.

External Temperature and Relative Humidity Sensor

Figure 3.1: The external temperature and relative humidity sensor (MR01).

Pin Probe and Cable

Figure 3.2: The pin probe (MR02) for penetrating moisture measurements.

4. Ntuziaka ọrụ

4.1 Gbanyụọ/ gbanyụọ

Pịa Ike button (usually located at the bottom of the device) to turn the meter on or off.

4.2 Ngosipụta karịrịview

Close-up of FLIR MR77 display showing moisture and temperature readings

Figure 4.1: Close-up of the MR77 display showing various readings.

The backlit LCD displays moisture readings, relative humidity, air temperature, dew point, and other relevant data. Icons indicate measurement mode, battery status, and other functions.

Ụdị nha 4.3

The FLIR MR77 offers multiple measurement capabilities:

Hand holding FLIR MR77 performing a pinless moisture measurement

Figure 4.2: Performing a pinless moisture measurement with the FLIR MR77.

Hand holding FLIR MR77 using the integrated IR thermometer with laser pointer

Figure 4.3: Using the integrated IR thermometer with laser targeting.

4.4 Material Group Selection

The MR77 allows selection of different material groups for more accurate moisture readings. Refer to the "Material Group Reference" table in the Specifications section for details on specific materials.

FLIR MR77 display showing material group and relative humidity

Figure 4.4: The display indicating the selected material group (M09) and Relative Humidity (RH).

4.5 Nchekwa na Ncheta Data

Jiri ihe Echekwaa/Cheta button to save and retrieve measurement data. Consult the full user manual for detailed instructions on data logging and management.

4.6 Meter Link Smartphone App

The FLIR MR77 can connect to a smartphone app via Bluetooth for enhanced data monitoring, comparison, and reporting. Download the Meter Link app from your device's app store.

Screenshots of the FLIR Meter Link smartphone app showing data logging and comparison features

Figure 4.5: The Meter Link smartphone app interface for data monitoring and comparison.

5. Nlekọta

5.1 Nhicha

Wipe the meter's exterior with a damp cloth. Do not use abrasive cleaners or solvents. Keep the sensor areas clean and free of debris.

5.2 Ndochi ihe mmetụta

The temperature/relative humidity sensor (MR01) is field-replaceable. If readings become inaccurate or the sensor is damaged, replace it with an authorized FLIR replacement part. Refer to the full user manual for detailed replacement instructions.

5.3 Nchekwa

Store the FLIR MR77 in a cool, dry place when not in use. Remove the battery if storing for extended periods to prevent leakage.

6. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Mita ahụ anaghị agba ọkụ.Batrị nwụrụ anwụ ma ọ bụ arụnyere na ezighi ezi.Check battery polarity, replace battery.
Ọgụgụ mmiri na-ezighi ezi.Incorrect material group selected; sensor dirty or damaged; external interference.Verify material group; clean or replace sensor; move away from strong electromagnetic fields.
Inaccurate RH/Temperature readings.Sensor dirty or damaged.Clean or replace the MR01 sensor.
Nsogbu njikọ Bluetooth.Meter not in pairing mode; app issues; distance from device.Ensure meter Bluetooth is active; restart app/meter; reduce distance.

For further assistance, refer to the official FLIR MR77 User Manual (PDF) or contact FLIR customer support.

7. Nkọwapụta

Nkọwa n'ozuzu:

Nkọwa nha:

FLIR MR77 Specifications including moisture and environmental measurements

Figure 7.1: Detailed specifications for the FLIR MR77.

Material Group Reference:

Table of Material Group Reference for FLIR MR77

Figure 7.2: Reference table for selecting appropriate material groups for moisture measurements.

This table provides common names of timbers and other materials, along with their corresponding material group numbers (e.g., Group 1-8 for timbers, Group 9 for plywood, drywall, and oriented strand board, Group 10 for brick, cement screed, and concrete, Group 11 for cement mortar, anhydrite screed, lime mortar, and plaster). Groups 10 and 11 are not specified for accuracy and should be used for reference only.

8. Akwụkwọ ikike Ozi

The FLIR MR77 Pinless Moisture Meter is covered by a Akwụkwọ ikike ndụ nwere oke. For specific terms and conditions, including details on coverage and how to make a warranty claim, please refer to the official warranty documentation provided with your product or visit the FLIR websaịtị.

9. Nkwado na Akụrụngwa Ndị Ọzọ

For further information, technical support, or to access the complete user manual, please use the resources below:

Akwụkwọ ndị emetụtara - MR77

Tupuview Ntuziaka Onye Ọrụ FLIR MR77: Pinless Moisture Psychrometer nwere Thermometer IR na Bluetooth
Akwụkwọ ntuziaka maka FLIR MR77, ihe na-eme ka mmiri dị nro nke nwere temometa infrared na njikọ Bluetooth METERLiNK. Mụta maka atụmatụ ya, ọrụ ya, na nkọwapụta ya.
Tupuview FLIR MR77 User's Manual: Pinless Moisture Psychrometer with IR Thermometer
User's manual for the FLIR MR77, a pinless moisture psychrometer featuring an infrared thermometer and Bluetooth METERLiNK connectivity. Learn about its features, operation, and technical specifications.
Tupuview FLIR MR59 Ball Probe Moisture Meter Quick Start Guide
Quick start guide for the FLIR MR59 Ball Probe Moisture Meter with Bluetooth, covering setup, operation, meter description, function buttons, display indicators, and Bluetooth connectivity.
Tupuview FLIR MR59 Ball Probe Moisture Meter User Manual with Bluetooth
User manual for the FLIR MR59 Ball Probe Moisture Meter with Bluetooth. Provides detailed information on features, operation, maintenance, specifications, and safety guidelines for accurate moisture detection in building materials.
Tupuview FLIR MR176 Imaging Moisture Meter Plus with IGM User Manual
User manual for the FLIR MR176 Imaging Moisture Meter Plus, detailing its features, operation, maintenance, and specifications. Learn how to use its thermal imaging, pinless, and pin probe moisture measurement capabilities.
Tupuview Ngwa ngwa ngwa FLIR E60: Ndepụta zuru oke nke ngwa igwefoto ọkụ
Ndepụta ngwa zuru ezu maka igwefoto onyonyo thermal FLIR E60, gụnyere ikpe, eriri, akụrụngwa ọkụ, chaja, batrị, kaadị ebe nchekwa, na akwụkwọ sitere na Advanced Test Equipment Corp.