1. Okwu mmalite
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Legrand LEG04704 Multifunction Timer. Please read these instructions carefully before installation and retain them for future reference.
The Legrand LEG04704 is a single-module multifunction timer designed for controlling lighting circuits with adjustable timing and various load types. It operates on a 230V~ 50/60Hz power supply and provides a 16A 250V output.
2. Akụrụngwa Ngwaahịa
- Module Count: 1 module.
- Ịnye ọkụ: 230 V~ 50/60 Hz.
- Mpụta: 16 A - 250 V~ (cos φ = 1).
- Oge a na-agbanwe agbanwe: Site na nkeji 0.5 ruo 12.
- Ndakọrịta ibu:
- Ọkụ lamps: 3680 W
- Halogen lamps (230 V~): 2000 W
- Halogen lamps with ferromagnetic transformer: 500 W
- Halogen lamps with electronic transformer: 2000 W
- Kọmpat fluorescent lamps: 1000 VA
- Fluorescent lamps (parallel compensated, ≤ 100 µF): 1000 VA
- Ịchekwa ume lamps: 1000 W
- Wiring: Automatic recognition for 3 or 4-wire operation.
- Ntinye njikwa: Separate inputs (8-230V) for presence detection or intercom lighting control.
- Ọrụ: End-of-timing pre-warning, 1-hour long duration function, and manual override.
- Nchedo: Self-protection mechanism in case of a blocked push-button.
- ndakọrịta: Accepts supply busbars.
- gburugburu: Ihe enwere ike imeghari.
3. Ozi nchekwa
Ịdọ aka ná ntị: Electrical installation should only be performed by qualified personnel in accordance with national wiring regulations and safety standards.
- Always disconnect the main power supply before performing any installation, maintenance, or wiring work.
- Gbaa mbọ hụ na ntọ ala kwesịrị ekwesị ebe achọrọ ya.
- Do not exceed the specified load ratings for the timer.
- Protect the device from moisture, dust, and extreme temperatures.
- Chọpụta njikọ niile echekwara tupu iweghachi ike.
4. Nwụnye
The Legrand LEG04704 timer is designed for DIN rail mounting within an electrical enclosure.

Image showing the Legrand LEG04704 multifunction timer. It is a grey, single-module device designed for DIN rail mounting. Visible features include screw terminals labeled 'N' and 'B' at the top, a timing adjustment dial marked from 0.5 to 12 minutes, and a manual override switch below it. The Legrand logo and model number '0047 04' are also visible. Lower terminals are labeled 'L' and '4'.
4.1. Ịkwanye
- Ensure the main power supply to the installation is disconnected.
- Clip the timer onto a standard DIN rail inside a suitable electrical enclosure.
4.2. Njikọ njikọ
Refer to the wiring diagram provided with the product and the labels on the device. The timer automatically recognizes 3 or 4-wire operation.
- N: Neutral connection.
- B: Input for control push-button (e.g., from a switch or presence detector).
- L: Live (Phase) input connection.
- 4: Switched Live (Phase) output to the load (e.g., lighting circuit).
Ensure all wire connections are tight and secure. Use appropriate wire gauges for the load current.
5. Ntuziaka ọrụ
5.1. Setting the Timer Duration
The timing duration can be adjusted using the rotary dial on the front of the device. Use a small screwdriver to turn the dial to the desired time setting, ranging from 0.5 minutes to 12 minutes.
5.2. Manual Override Switch
The timer features a manual override switch, typically located below the timing dial. This switch allows for continuous operation or manual OFF, bypassing the timed function. Refer to the symbols on the device for specific positions (e.g., timed operation, continuous ON, continuous OFF).
5.3. Ọrụ Pụrụ Iche
- Pre-warning Function: The timer may provide a visual indication (e.g., a brief flicker of the light) before the end of the timing period, allowing users to react before the light switches off.
- Long Duration Function: A specific input or sequence might activate a 1-hour timing period, useful for extended lighting needs.
6. Nlekọta
The Legrand LEG04704 timer requires minimal maintenance.
- Hụ na ewepụla ọkụ eletrik tupu ị sachaa ya.
- Jiri ákwà dị nro ma kpọọ nkụ hichaa mpụta ya. Ejila ihe nhicha ma ọ bụ ihe mgbaze.
- There are no user-serviceable parts inside the device. Do not attempt to open or repair the timer.
7. Nchọpụta nsogbu
- Timer not activating:
- Check if the main power supply is connected and active.
- Verify all wiring connections (L, N, B, 4) are correct and secure.
- Ensure the control push-button is functioning correctly.
- Check the manual override switch position.
- Incorrect timing duration:
- Adjust the rotary dial to the desired time setting.
- Load not switching off:
- Check the manual override switch position; it might be set to continuous ON.
- Ensure the load does not exceed the maximum specified rating.
- If issues persist, consult a qualified electrician or contact Legrand customer support.
8. Nkọwapụta
| Ụdị | Legrand |
| Nlereanya | LEG04704 |
| Ịnye ọkụ | 230V ~ 50/60 Hz |
| Mmepụta ugbu a | 16 A |
| Mmepụta Voltage | 250 V~ (cos φ = 1) |
| Ogologo oge | Nkeji 0.5 ruo 12 |
| Nha modul | 1 modul |
| Ihe onwunwe | PVC |
| Agba | Agba ntụ |
| Ibu Ibu | 92 grams |
| GTIN | 03245060047047 |
9. Akwụkwọ ikike na nkwado
Legrand products are manufactured to high-quality standards and are covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Legrand websaịtị.
For technical support, troubleshooting assistance, or inquiries regarding your Legrand LEG04704 Multifunction Timer, please contact Legrand customer service through their official channels.