This manual provides detailed instructions for the safe and efficient installation, operation, and maintenance of your Schellenberg 20615 Maxi Standard Tubular Motor. Please read this manual thoroughly before beginning any procedures to ensure proper use and to prevent damage or injury.

Akụkụ ndị bụ isi:

2. Ntuziaka nchekwa

Ịdọ aka ná ntị: Failure to follow these safety instructions could result in electric shock, fire, and/or serious injury.

3. Ihe ngwugwu

Nyochaa na etinyere ihe niile edepụtara n'okpuru na ngwugwu gị:

Schellenberg 20615 Maxi Standard Tubular Motor with accessories

Image 3.1: Complete package contents including the tubular motor, adapter, wall bracket, end stop adjustment tool, and mounting hardware.

4. Nka na ụzụ nkọwa

Onye nrụpụtaỤlọ ọrụ Alfred Schellenberg GmbH
Nọmba nlereanya20615
Akụkụ ngwaahịa58 x 10.5 x 7.5 cm
Ibu Ibu2.84 n'arọ
Size/Torque15 Nm Maxi
ỤdịỌkọlọtọ
Ihe onwunwePlastic
Wattage138 watt
Ọnụọgụ nke ihe1
Ngbanwe Ụdị1 way, Emergency switch
Electrical Socket TypeEnwere ike ịgbanye mgbidi
AsambodoIP44, installation safety standard
Agụnyere batrị / achọrọMba
Schellenberg 20615 Maxi Standard Tubular Motor with dimensions

Foto 4.1: Zuru ezu view of the Schellenberg 20615 motor with key dimensions highlighted.

5. Nwụnye

The Schellenberg 20615 motor is designed for easy integration into existing roller shutter systems with 60 mm octagonal shafts. Ensure all safety precautions are followed before proceeding.

5.1 Preparing the Roller Shutter

  1. Disconnect power to the roller shutter system at the main circuit breaker.
  2. Remove the existing roller shutter mechanism from the octagogwe onal.
  3. Ensure the roller shutter box is clean and free of debris.

5.2 Installing the Tubular Motor

  1. Attach the provided adapter to the motor head. The adapter ensures optimal power transmission to the roller shutter shaft.
  2. Slide the tubular motor into the 60 mm octagonal shaft. Ensure it fits snugly.
  3. Secure the motor and shaft assembly using the wall bracket and mounting hardware.
  4. Connect the motor's electrical wires (brown, blue, black, green/yellow) to the appropriate power supply and control switch, following local electrical codes.
Close-up of Schellenberg 20615 motor head with wiring

Foto 5.1: nso nso view of the Schellenberg 20615 motor head, showing the wiring connections and adjustment screws.

Video 5.1: Product Summary - This video provides an overview of the Schellenberg tubular motor and its features, demonstrating its application in roller shutter systems.

6. Ọrụ

Once installed, the motor can be operated via a wall switch or a compatible remote control (sold separately).

6.1 Setting End Stops (Mechanical Adjustment)

The motor features mechanical end stop adjustment. Use the provided adjustment tool (rangefinder) to set the upper and lower limits of the roller shutter's travel.

  1. Locate the two adjustment screws on the motor head (often colored yellow and white).
  2. Use the adjustment tool to turn the screws. One screw controls the upper limit, the other controls the lower limit.
  3. Operate the roller shutter up and down to test the limits. Adjust as necessary until the desired positions are reached. Turning the screw in one direction extends the travel, while turning it in the other shortens it.
Hand adjusting end stop screw on tubular motor

Image 6.1: A hand using the adjustment tool to set the mechanical end stops on the tubular motor. The screws are typically located on the motor head.

Video 6.1: Motor End Stop Adjustment - This video demonstrates the process of mechanically adjusting the upper and lower end stops of the tubular motor for precise roller shutter positioning.

6.2 Using a Wall Switch

Press the "Up" button to raise the roller shutter and the "Down" button to lower it. Pressing the button again during movement will stop the shutter.

Woman operating a wall switch for roller shutters

Image 6.2: A person operating a wall-mounted switch to control the roller shutter.

Video 6.2: Roller Shutter Switch With RF Remote Control - This video illustrates how to operate a roller shutter using a wall switch, including integration with an RF remote control system.

7. Nlekọta

The Schellenberg tubular motor is designed for long-term, maintenance-free operation. However, periodic checks can help ensure its longevity and optimal performance.

8. Nchọpụta nsogbu

If you encounter problems with your Schellenberg tubular motor, refer to the following common issues and solutions:

NsogbuIhe nwere ike imeNgwọta
moto anaghị azaNo power supply; faulty switch/remote; motor overload protection activated.Check power connection and circuit breaker. Test switch/remote. Allow motor to cool down if it has been continuously operated.
Roller shutter stops prematurelyIncorrectly set end stops; obstruction in the path.Re-adjust end stops (refer to Section 6.1). Remove any obstructions.
Mkpọtụ na-adịghị ahụkebe n'oge arụ ọrụObstruction; worn components; motor malfunction.Lelee ma ọ bụrụ na mkpọtụ anọgide, kpọtụrụ ọkachamara n'ihe gbasara ọrụ.

9. Akwụkwọ ikike na nkwado

Schellenberg products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Schellenberg websaịtị.

For technical support, troubleshooting assistance, or spare parts, please contact Schellenberg customer service:

Akwụkwọ ndị emetụtara - 20615

Tupuview Schellenberg ROLLOPOWER PLUS / STANDARD Roller Shutter Motor Installation Manual
Comprehensive installation and user manual for the Schellenberg ROLLOPOWER PLUS and STANDARD roller shutter motors, including model numbers, safety instructions, assembly steps, wiring diagrams, and end-position adjustment procedures.
Tupuview Schellenberg Rollladen-Gurtwickler Maxi Safety Instructions and Warnings
Read important safety precautions and warnings for the Schellenberg Rollladen-Gurtwickler Maxi (model 10425049) from Alfred Schellenberg GmbH. Ensure safe usage and handling.
Tupuview Schellenberg Gurtführung Standard Mini: ⚠ Safety Instructions
Essential safety instructions and warnings for the Schellenberg Gurtführung mit Doppelleiterrolle Standard Mini (14mm belt width). Covers safe operation, child safety, and packaging hazards for roller shutter systems.
Tupuview SCHELLENBERG Notentriegelungsschloss Modell 60611 Montagnke ọma
Montageanleitung für das SCHELLENBERG Notentriegelungsschloss, Modell 60611. Bietet detaillierte Anweisungen für die sichere und korrekte Installation dieses Sicherheitsgeräts.
Tupuview Schellenberg Funk-Codierschloss 60872: Montage- und Bedienungsanleitung
Detaillierte Anleitung für das Schellenberg Funk-Codierschloss Modell 60872. Erfahren Sie, wie Sie das Gerät installieren, PIN-Codes ändern und mit Garagentorantrieben koppeln. Mehrsprachig verfügbar.
Tupuview Schellenberg Garagentorantrieb 600P, 700P, 850P Bedienungsanleitung
Umfassende Anleitung für den Schellenberg Garagentorantrieb Modelle 600P, 700P und 850P. Enthält Informationen zu Montage, Bedienung, Sicherheitshinweisen und Fehlerbehebung.