The YSI 251398Y DPD Free Chlorine Reagent Powder is designed for accurate measurement of free chlorine in water samples using a compatible colorimeter. Each pack contains 100 individual powder packs, with each pack formulated for a 5ml sample volume and capable of measuring free chlorine in the range of 0 to 3.5 mg/L.

This reagent utilizes the DPD (N,N-Diethyl-p-phenylenediamine) method, which reacts with free chlorine to produce a magenta color, the intensity of which is proportional to the chlorine concentration and measured by a colorimeter.

Ozi nchekwa

Always handle chemical reagents with care. Read the Safety Data Sheet (SDS) for this product before use. Wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when handling the reagent powder. Avoid ingestion and contact with skin or eyes. In case of contact, rinse thoroughly with water and seek medical attention if irritation persists.

Nhazi na Nkwadebe

Before beginning any measurements, ensure you have the following:

  • YSI 251398Y DPD Free Chlorine Reagent Powder pack
  • Compatible colorimeter or spectrophotometer
  • Dị ọcha sample cells/vials
  • Deionized or distilled water for blanks and dilutions (if necessary)
  • Mmiri sample to be tested
  • Ngụ oge

Nzọụkwụ Nkwadebe:

  1. Ensure all glassware and sample cells are clean and free from contamination. Rinse with deionized water before use.
  2. Calibrate your colorimeter according to its specific instruction manual before use.

Ntuziaka ọrụ

Follow these steps to accurately measure free chlorine using the YSI 251398Y DPD Free Chlorine Reagent Powder:

  1. Sampmkpokọta: Collect a fresh water sample in a clean sample cell. The required volume is 5ml. Ensure the sample is representative of the water being tested.
  2. Add Reagent: Carefully tear open one YSI 251398Y DPD Free Chlorine Reagent Powder pack. Add the entire contents of the powder pack to the 5ml water sample na sample cell.
  3. Ngwakọta: Kpuchie sample cell and invert several times to thoroughly mix the reagent with the sample. Ensure all powder dissolves completely. A magenta color will develop if free chlorine is present.
  4. Oge mmeghachi omume: Allow a reaction time of 1 minute for the color to fully develop. Do not exceed 6 minutes, as color fading may occur, leading to inaccurate results.
  5. Ntụ: Insert the prepared sample cell into your calibrated colorimeter. Follow your colorimeter's instructions to initiate the measurement. The colorimeter will display the free chlorine concentration in mg/L.
  6. Record Results: Record the measured free chlorine concentration.
Close-up of a silver foil reagent powder packet with 'VARIO.LIT Chlorine FREE-DPD' printed on it.

Image: A single YSI DPD Free Chlorine Reagent Powder packet. This silver foil packet contains the pre-measured reagent powder for a single test. The text "VARIO.LIT Chlorine FREE-DPD" is visible on the packet, indicating its contents and purpose.

Nlekọta na Nchekwa

Proper storage and handling are crucial for maintaining the integrity and effectiveness of the reagent powder:

  • Nchekwa: Store the reagent powder packs in their original packaging in a cool, dry place, away from direct sunlight and extreme temperatures. Do not store near strong acids or bases.
  • Ndụ nchekwa: Refer to the expiration date printed on the packaging. Do not use expired reagents, as they may yield inaccurate results.
  • mkpofu: Dispose of used reagent and sample solutions according to local environmental regulations. Consult your local authorities for proper chemical waste disposal procedures.
  • Ịdị ọcha: Always ensure sample cells and equipment are thoroughly cleaned after each use to prevent cross-contamination.

Nchọpụta nsogbu

If you encounter issues during testing, consider the following common problems and solutions:

NsogbuIhe nwere ike imeNgwọta
No color developmentNo free chlorine present; Expired reagent; Incorrect sample olu.Verify sample contains chlorine; Check reagent expiration date; Ensure 5ml sample olu.
Fading color or inaccurate readingReaction time exceeded; Contaminated sample cell; Turbidity in sample.Adhere strictly to 1-minute reaction time; Clean sample cells thoroughly; Filter turbid samples ma ọ bụrụ na ọ dị mkpa.
Nsonaazụ na-ekwekọghị ekwekọImproper mixing; Temperature variations; Colorimeter not calibrated.Ensure complete dissolution of powder; Perform tests at consistent temperatures; Recalibrate colorimeter.

Nkọwapụta

  • Aha ngwaahịa: YSI DPD Free Chlorine Reagent Powder
  • Nọmba nlereanya: 251398Y
  • Reagent Type: DPD (N,N-Diethyl-p-phenylenediamine)
  • Analyte: Chlorine efu (Cl2)
  • Sampna olu: 5 ml
  • Oke nha: 0 ruo 3.5 mg/L (ppm)
  • Nkwakọ ngwaahịa: Powder packs, 100 per pack
  • Onye nrụpụta: YSI
  • ASIN: B00CMX0PDK
  • Akụkụ ngwugwu: 8.1 x 6.9 x 1.2 sentimita asatọ
  • Ibu ihe: 3.2 ounces

Akwụkwọ ikike na nkwado

For information regarding product warranty, technical support, or to purchase additional reagents, please contact YSI customer service or visit the official YSI website. Refer to your purchase documentation for specific warranty terms and conditions.

YSI Contact Information:

  • Websaịtị: www.ysi.com (Please note: This is a placeholder link, refer to official YSI documentation for exact contact details.)

Akwụkwọ ndị emetụtara - 251398Y

Tupuview Ihe Nlereanya YSI 32 ntuziaka ntuziaka ntuziaka
Ntuziaka ntuziaka maka YSI Model 32 Conductance Mita, na-akọwapụta nkọwa ya n'ozuzu ya, nkọwapụta, usoro ọrụ, mmezi na nhazi ya.
Tupuview YSI Pro20/Pro20i Quick Start Guide: Calibration and Operation
Concise guide for calibrating and operating the YSI Pro20/Pro20i dissolved oxygen meters, covering membrane installation, sensor setup, barometer and DO calibration, salinity compensation, and measurement taking. Includes essential operational steps and contact information.
Tupuview YSI 3821 Buffer Solution pH 4.00 Mpempe akwụkwọ data nchekwa (SDS)
Mpempe akwụkwọ data nchekwa zuru oke (SDS) maka YSI 3821 Buffer Solution pH 4.00, na-akọwapụta njirimara ngwaahịa, ihe egwu, mejupụtara, enyemaka mbụ, njikwa, nchekwa na ozi nhazi.
Tupuview YSI EcoSense DO200A/DO200M Dissolved Oxygen and Temperature Instruments User Manual
This user manual provides comprehensive instructions for operating, installing, maintaining, and troubleshooting the YSI EcoSense DO200A and DO200M dissolved oxygen and temperature instruments. It includes details on specifications, accessories, and warranty information.
Tupuview YSIT-1 Ntuziaka Satịlaịtị Ọrụ na Nlekọta
Akwụkwọ ntuziaka onye ọrụ zuru oke maka YSI Model YSIT-1 Satellite Transmitter, na-ekpuchi ọrụ ya, mmezi ya, ntọlite ​​ngwaike, yana nrụtụ aka iwu. Nkọwa gụnyere njikwa oge, nchekwa data, nhazi data GOES, njikwa nnyefe RF, yana mmekọrịta GPS.
Tupuview YSI IQ Sensor Net MIQ/CHV PLUS Akwụkwọ ntuziaka na-arụ ọrụ
Akwụkwọ ntuziaka a na-enye ntuziaka zuru ezu maka modulu valvụ YSI IQ Sensor Net MIQ/CHV PLUS, nke na-ekpuchi ntinye, ntọala, mmezi, na ntuziaka nchekwa maka isi nhicha sensọ ejiri ikuku rụọ.