The YSI 251401Y DPD Free Chlorine Reagent Powder is an EPA-approved chemical reagent designed for accurate measurement of free chlorine concentrations. This product is specifically formulated for use with YSI pHotoFlex and 900 Chlorine Colorimeter instruments, providing reliable results within a range of 0.02 to 2 mg/L. Each pack contains 100 individual 10ml volume powder packets, ensuring convenience and consistent dosing for laboratory and field applications.

YSI 251401Y DPD Free Chlorine Reagent Powder Packet

Image 1.1: A single packet of YSI 251401Y DPD Free Chlorine Reagent Powder. The label indicates "Powder Packets," "Part Number: 251401Y," "Lot Code: L 01 A," and "Exp: 01.2017." It also includes safety warnings and manufacturer contact information.

2. Safety Information and Handling

This product is intended for professional laboratory and field use only. Adherence to all safety guidelines is critical for proper and safe operation.

3. Nhazi na Nkwadebe

Before beginning any measurement, ensure you have the necessary equipment and that your colorimeter is calibrated according to its specific user manual.

3.1 Required Materials (Not Included)

3.2 Nkwadebe Reagent

The YSI 251401Y DPD Free Chlorine Reagent is provided in pre-measured powder packets, eliminating the need for manual weighing or dilution. Each packet contains the precise amount of reagent for a 10ml sample olu.

4. Operating Instructions for Free Chlorine Measurement

Follow these steps for accurate free chlorine measurement using the YSI 251401Y DPD Free Chlorine Reagent Powder with a compatible YSI colorimeter.

  1. Kwadebe SampCell: Rinse a clean sample cell thoroughly with deionized water, then with a small amount of the sample ka a nwale.
  2. Jupụta SampCell: Jupụta sample cell with 10 ml of the water sample to be analyzed. Ensure the sample volume is precise.
  3. Add Reagent: Carefully open one YSI 251401Y DPD Free Chlorine Reagent Powder packet. Add the entire contents of the powder packet to the 10 ml sample na cell.
  4. Ngwakọta: Kpuchie sample cell and invert it gently several times to dissolve the powder completely. Avoid shaking vigorously, which can introduce air bubbles. A pink color will develop if free chlorine is present.
  5. Oge mmeghachi omume: Allow a reaction time of approximately 1 minute for the color to fully develop. Consult your colorimeter's manual for specific reaction time recommendations.
  6. tụọ: Insert the prepared sample cell into the YSI pHotoFlex or 900 Chlorine Colorimeter. Follow the instrument's instructions to initiate the measurement. The colorimeter will display the free chlorine concentration in mg/L.
  7. Record Results: Record the measurement results immediately.
  8. Hichapụ: After measurement, empty the sample cell and rinse it thoroughly with deionized water.

Mara: For best results, perform measurements promptly after sample collection. The DPD method is sensitive to light and temperature; protect samples and reagents from direct sunlight and extreme temperatures.

5. Mmezi na Nchekwa

Proper storage of the reagent packets is essential to maintain their integrity and ensure accurate results.

6. Nchọpụta nsogbu

This section addresses common issues that may arise during the use of the DPD Free Chlorine Reagent.

NsogbuIhe nwere ike imeNgwọta
No color development or faint color when chlorine is expected.
  • Expired reagent.
  • Insufficient mixing.
  • Sample pH outside optimal range.
  • Interfering substances in sample.
  • Check expiration date; use fresh reagent.
  • Ensure complete dissolution of powder.
  • Verify sample pH is within the colorimeter's specified range for DPD method.
  • Consult colorimeter manual for known interferences.
Ọgụgụ na-ekwekọghị ekwekọ ma ọ bụ na-agbanwe agbanwe.
  • Na-ekwesịghị ekwesị sample olu.
  • Emeru sample cell.
  • Air bubbles in sample cell.
  • Colorimeter calibration issue.
  • Ensure precise 10 ml sample olu.
  • Thoroughly clean sample cells before each use.
  • Gently invert to mix, avoid vigorous shaking.
  • Perform colorimeter calibration as per instrument manual.

7. Nkọwapụta

8. Akwụkwọ ikike na nkwado

For technical support, product inquiries, or to request a Safety Data Sheet (SDS), please contact YSI directly using the information below.

YSI stands behind the quality of its products. Please refer to the official YSI website or contact customer support for detailed warranty information applicable to this reagent.

Akwụkwọ ndị emetụtara - 251401Y

Tupuview Ihe Nlereanya YSI 32 ntuziaka ntuziaka ntuziaka
Ntuziaka ntuziaka maka YSI Model 32 Conductance Mita, na-akọwapụta nkọwa ya n'ozuzu ya, nkọwapụta, usoro ọrụ, mmezi na nhazi ya.
Tupuview YSI Pro20/Pro20i Quick Start Guide: Calibration and Operation
Concise guide for calibrating and operating the YSI Pro20/Pro20i dissolved oxygen meters, covering membrane installation, sensor setup, barometer and DO calibration, salinity compensation, and measurement taking. Includes essential operational steps and contact information.
Tupuview YSI 3821 Buffer Solution pH 4.00 Mpempe akwụkwọ data nchekwa (SDS)
Mpempe akwụkwọ data nchekwa zuru oke (SDS) maka YSI 3821 Buffer Solution pH 4.00, na-akọwapụta njirimara ngwaahịa, ihe egwu, mejupụtara, enyemaka mbụ, njikwa, nchekwa na ozi nhazi.
Tupuview YSI EcoSense DO200A/DO200M Dissolved Oxygen and Temperature Instruments User Manual
This user manual provides comprehensive instructions for operating, installing, maintaining, and troubleshooting the YSI EcoSense DO200A and DO200M dissolved oxygen and temperature instruments. It includes details on specifications, accessories, and warranty information.
Tupuview YSIT-1 Ntuziaka Satịlaịtị Ọrụ na Nlekọta
Akwụkwọ ntuziaka onye ọrụ zuru oke maka YSI Model YSIT-1 Satellite Transmitter, na-ekpuchi ọrụ ya, mmezi ya, ntọlite ​​ngwaike, yana nrụtụ aka iwu. Nkọwa gụnyere njikwa oge, nchekwa data, nhazi data GOES, njikwa nnyefe RF, yana mmekọrịta GPS.
Tupuview YSI IQ Sensor Net MIQ/CHV PLUS Akwụkwọ ntuziaka na-arụ ọrụ
Akwụkwọ ntuziaka a na-enye ntuziaka zuru ezu maka modulu valvụ YSI IQ Sensor Net MIQ/CHV PLUS, nke na-ekpuchi ntinye, ntọala, mmezi, na ntuziaka nchekwa maka isi nhicha sensọ ejiri ikuku rụọ.