1. Okwu mmalite

This manual provides comprehensive instructions for the proper use and maintenance of your Horizon SF-400D Digital Precision Scale. Please read this manual thoroughly before operating the device to ensure accurate measurements and prolong its lifespan.

The Horizon SF-400D is a versatile digital precision scale designed for various weighing applications, including jewelry, coins, herbs, spices, and medication. It offers high accuracy and multiple weighing modes, along with a convenient counting function.

Horizon SF-400D Digital Precision Scale

Foto 1: Horizon SF-400D Digital Precision Scale. This image shows the overall design of the scale, featuring a black body, a stainless steel weighing platform, and a blue backlit LCD display with control buttons.

2. Nchekwa nchekwa

  • Do not overload the scale beyond its maximum capacity of 500g.
  • Zere ikpughe oke okpomọkụ, iru mmiri, ma ọ bụ ìhè anyanwụ kpọmkwem.
  • Debe ọnụ ọgụgụ ahụ pụọ na mpaghara electromagnetic siri ike.
  • Jiri nwayọ hichaa ọnụ ọgụgụ, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ tinye akụkụ ahụ n'ime mmiri.
  • Ensure the scale is placed on a stable, level surface during operation to ensure accuracy.

3. Ngwa ngwaahịa

Familiarize yourself with the main parts of your SF-400D scale:

  • Platform ịtụ atụ: Stainless steel surface for placing items.
  • Ngosipụta LCD: Backlit screen showing weight, units, and other indicators.
  • Bọtịnụ ngbanwu/ Gbanyụọ: Na-agbanye nha ma ọ bụ gbanyụọ.
  • Bọtịnụ MODE: Changes weighing units (g, oz, ct, dwt, gn, T).
  • Bọtịnụ TARE: Resets the display to zero, useful for weighing items in a container.
  • PCS Button: Activates the piece counting function.
  • CAL Button: Used for calibration.
  • Ụkwụ na-agbanwe agbanwe: Located on the bottom for leveling the scale.
  • Ọkwa afụ: Integrated on the scale to assist with leveling.
SF-400D Scale Display and Buttons

Foto 2: Close-up of the SF-400D display and control buttons. This image highlights the LCD screen, showing various unit indicators (g, ct, dwt, gn, T, oz), and the function buttons: PCS, MODE, TARE, ON/OFF, and CAL.

SF-400D Scale Adjustable Legs

Foto 3: Underside of the SF-400D scale showing adjustable legs. Green arrows indicate the location of the four adjustable feet, which are used to level the scale for accurate measurements.

4. Nhazi

4.1. Ike inye

The SF-400D scale operates on two AA batteries (included) or an optional AC power adapter (not included).

  1. Mepee mkpuchi mkpuchi batrị n'okpuru ọnụ ọgụgụ.
  2. Tinye batrị AA abụọ, hụ na polarity ziri ezi (+/-).
  3. Mechie oghere batrị.
  4. Alternatively, connect a compatible AC power adapter (6V, amperage not specified in product details, consult manufacturer if needed) to the power port.

4.2. Ntinye na ọkwa

For optimal accuracy, the scale must be placed on a stable, flat, and level surface.

  1. Place the scale on your desired weighing surface.
  2. Observe the integrated bubble level.
  3. Adjust the four adjustable legs on the bottom of the scale by rotating them until the bubble is centered within the level indicator.

5. Ntuziaka ọrụ

5.1. Basic Weighing

  1. Pịa Gbanye/ Gbanyụọ button to turn on the scale. The display will show "88888" and then "0.00" (or "0.0" depending on the unit).
  2. If the display does not show zero, press the NA-EGO bọtịnụ ka efu nha nha.
  3. Pịa MODE button to select your desired weighing unit (g, oz, ct, dwt, gn, T).
  4. Gently place the item(s) to be weighed on the center of the stainless steel platform.
  5. Read the stable weight displayed on the LCD screen.
  6. Iji gbanyụọ nha ahụ, pịa ma jide ya Gbanye/ Gbanyụọ button for a few seconds. The scale also features an auto shut-off function to conserve battery power.

5.2. Ọrụ Tare

The Tare function allows you to subtract the weight of a container, so only the contents are weighed.

  1. Debe ihe efu n'elu ikpo okwu nha.
  2. Wait for the display to stabilize and show the container's weight.
  3. Pịa NA-EGO button. The display will reset to "0.00" (or "0.0").
  4. Add the items you wish to weigh into the container. The display will now show only the net weight of the items.
  5. To clear the tare, remove all items from the platform and press NA-EGO again if the display does not return to zero automatically.

5.3. Piece Counting Function (PCS)

This function is useful for counting multiple identical items.

  1. Turn on the scale and ensure it is zeroed.
  2. Pịa PCS button. The display will show "PCS" and a sample size (e.g., "25", "50", "75", "100").
  3. Pịa MODE button to cycle through the available sample sizes (25, 50, 75, 100 pieces). Select the sample size that matches the number of items you will place on the scale for sampegbu oge.
  4. Place the exact number of sample items (e.g., 25 pieces) onto the weighing platform according to your selected sample size.
  5. Pịa PCS button again to confirm the sample. The display will now show the number of pieces.
  6. You can now add more items of the same type, and the scale will display the total count.
  7. To exit the counting mode, press the MODE bọtịnụ.

5.4. nhazi nhazi

Calibration ensures the accuracy of your scale. It is recommended to calibrate the scale periodically or if you suspect inaccurate readings. You will need a known calibration weight (e.g., 500g) for this process.

SF-400D Scale Calibration Display

Foto 4: SF-400D display showing "CAL" during calibration mode. This image illustrates the scale's screen indicating it is in calibration mode, prompting the user to place a calibration weight.

  1. Ensure the scale is on a stable, level surface and turned off.
  2. Pịa ma jide CAL bọtịnụ, wee pịa bọtịnụ Gbanye/ Gbanyụọ button simultaneously. Release both buttons when the display shows "CAL".
  3. The display will then show a flashing weight value (e.g., "500.00g"). This is the required calibration weight.
  4. Place the exact calibration weight (e.g., 500g) onto the center of the weighing platform.
  5. Wait for the display to stabilize and show "PASS" or return to normal weighing mode. This indicates successful calibration.
  6. Remove the calibration weight. The scale is now calibrated and ready for use.
  7. If "FAIL" or an error message appears, repeat the calibration process.

6. Nlekọta

6.1. Nhicha

  • Wipe the scale surface with a soft, slightly damp akwa .
  • Ejila kemịkalụ siri ike, ihe nhicha ihe na-emebi emebi, ma ọ bụ mikpuo ihe mkpuchi ahụ n'ime mmiri.
  • Gbaa mbọ hụ na ọnụ ọgụgụ ahụ akpọnwụwo kpamkpam tupu nchekwa ma ọ bụ ojiji ọzọ.

6.2. Nchekwa

  • Chekwaa ọnụ ọgụgụ ahụ n'ebe dị jụụ, kpọrọ nkụ, pụọ na ìhè anyanwụ kpọmkwem na oke okpomọkụ.
  • Ọ bụrụ na ị na-echekwa ruo ogologo oge, wepụ batrị ahụ ka ọ ghara ịwụpụ.

7. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Ọkwa anaghị agbanye.Low or dead batteries; incorrect battery installation; no power from AC adapter.Replace batteries; check battery polarity; ensure AC adapter is properly connected and functional.
Ọgụgụ na-ezighi ezi.Scale not level; unstable surface; needs calibration; overloaded; strong air currents or vibrations.Ensure scale is level using adjustable legs and bubble level; place on stable surface; perform calibration; do not exceed 500g capacity; operate in a stable environment.
"O_Ld" or "EEEE" displayed.Ọkọlọtọ bujuru oke.Remove excess weight immediately. Do not exceed 500g capacity.
Display shows "UNST".Unstable environment or surface.Move the scale to a more stable location, away from vibrations or drafts.
Counting function not working correctly.ezighi eziample size selected; sample items not identical in weight.Gbaa mbọ hụ na sample size matches the number of items placed for sampling; use identical items for accurate counting.

8. Nkọwapụta

NjirimaraNkọwa
NlereanyaSF-400D
Ike500 grams (g) / 17.5 ounces (oz)
Accuracy (Readability)0.01 grams (g) / 0.0005 ounces (oz)
Ụdị atụg (grams), oz (ounces), ct (carats), dwt (pennyweights), gn (grains), T (troy ounces), pcs (pieces)
Ngwa PlatformIgwe anaghị agba nchara
Platform Diameter4.2 sentimita asatọ
NgosipụtaLCD nwere ọkụ azụ
Ike2 x AA batteries (included) or 6V AC adapter (not included)
Akụkụ (L x W x H)8.25" x 6.0" x 1.75"
AtụmatụTare function, Piece Counting, Auto Shut-Off, Backlit Display, Adjustable Legs, Bubble Level

9. Akwụkwọ ikike na nkwado

For warranty information or technical support, please refer to the documentation included with your purchase or contact the retailer. Specific warranty terms may vary by region and retailer.

For general inquiries or to explore other products, you may visit the Horizon Store on Amazon.

Akwụkwọ ndị emetụtara - SF-400D

Tupuview SF-400D Digital Scale User Manual
User manual for the SF-400D digital scale, covering specifications, counting function, unit conversion, tare function, calibration, and handling instructions.
Tupuview Horizon TV gị: Ntuziaka mmalite ngwa ngwa maka gụgharia na ndekọ
Ntuziaka zuru oke maka ịtọlite ​​​​na iji Horizon TV gị, gụnyere ịnyagharị menus, ịnweta ntuziaka TV, ịdekọ mmemme, iji ọrụ Watch TV Everywhere, na ijikwa ọdịnaya gị.
Tupuview Horizon HZ51 5G Wi-Fi 6 AX5400 CPE Ntuziaka mmalite ngwa ngwa
Ntuziaka mmalite ngwa ngwa maka Horizon HZ51 5G Wi-Fi 6 AX5400 CPE, nhazi mkpuchi, nhazi, njikọta, nchọpụta nsogbu na ozi nchekwa.
Tupuview Horizon DG505G 5G/LTE CBRS USB-C Dongle Quick Start Guide
Quick start guide for the Horizon DG505G 5G/LTE CBRS USB-C Dongle. Learn how to insert the SIM card, connect the dongle to your device, check the LED indicator, access the Web UI for configuration, and review regulatory information.
Tupuview Horizon Remote Control User Guide
A comprehensive guide to the Horizon remote control, detailing its features, functions, and setup for connecting with Horizon boxes and televisions. Includes instructions for both front and rear controls, and troubleshooting tips.
Tupuview Akwụkwọ ndekọ aha ndị na-enye ọgwụ Horizon 2020 - Southern New Jersey
Akwụkwọ ndekọ aha 2020 a depụtara ndị dibịa na ndị ọkachamara ahụike maka Horizon Medicare Blue Advan.tage (HMO) na Horizon Medicare Blue Select (HMO-POS) atụmatụ na South New Jersey mpaghara. Chọta ndị na-eweta netwọk wee nweta ngwa nchọta n'ịntanetị.