1. Okwu mmalite
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Finder 140182300000PAS Multifunction Timer/Staircase Relay. Please read this manual carefully before installation and use to ensure proper function and safety.
2. Ozi nchekwa
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel in accordance with all local and national electrical codes.
- Kwụpụ ọkụ eletrik mgbe niile tupu ị wụnye ma ọ bụ rụzie ngwaọrụ ahụ.
- Ensure the device is installed in a suitable enclosure to protect against environmental factors.
- Verify correct wiring connections to prevent damage to the device or connected equipment.
- Agafela voltage na ọkwa dị ugbu a.
3. Ngwaahịa gafereview
The Finder 140182300000PAS is a versatile multifunction timer and staircase relay designed for various electrical control applications. It features a 230V operating voltage, a 1 NO (normally open) contact, and a 16A current rating. Its compact design allows for easy integration into electrical panels.

Foto 1: N'ihu view of the Finder 140182300000PAS Multifunction Timer/Staircase Relay. This image shows the device's casing, terminals, and the adjustable timer dial.

Foto 2: Example application of the Finder 140182300000PAS controlling staircase lighting. The relay is shown in an inset, demonstrating its use in a typical residential or commercial setting.

Foto 3: Another application example, showing the Finder 140182300000PAS managing lighting for a modern spiral staircase. This highlights the device's suitability for various architectural lighting designs.
4. Ntọala na nwụnye
4.1 Akụkụ anụ ahụ
Refer to the dimensional drawing for precise measurements to ensure proper fit and mounting.

Foto 4: Dimensional drawing for the Type 14.01 relay, showing height, width, and depth in millimeters. This diagram is crucial for planning installation space.
4.2 eserese waya
The Finder 140182300000PAS supports both 3-wire and 4-wire connection types. Select the appropriate diagram for your installation.

Foto 5: Wiring Diagram Type 14.01 for a 3-wire connection. This diagram illustrates how to connect the relay to the power supply and load using a 3-wire configuration, typically for staircase lighting with a common neutral.

Foto 6: Wiring Diagram Type 14.01 for a 4-wire connection. This diagram shows the connections for a 4-wire setup, which might be used in systems requiring separate control wires for the relay and the load.
5. Ntuziaka ọrụ
5.1 Timer Adjustment
The device features an adjustable timer dial on its front face. To set the desired timing duration:
- Locate the orange dial labeled 'T(min)' on the front of the relay.
- Rotate the dial to align the indicator with the desired time setting (e.g., 5, 10, 15, 20 minutes).
- The selected time will determine how long the connected load remains active after activation.
5.2 Multifunction Operation
The Finder 140182300000PAS operates as both a staircase timer and a multifunction relay. When activated (e.g., by a push-button switch), the relay will close its contact, powering the connected load for the duration set on the timer. It can be used for applications such as:
- Staircase lighting control.
- Timed ventilation systems.
- General purpose timed switching.
6. Nlekọta
The Finder 140182300000PAS is designed for long-term, maintenance-free operation. However, periodic checks are recommended:
- Gbaa mbọ hụ na njikọ waya niile ka dị nchebe.
- Debe ngwaọrụ ahụ pụọ na uzuzu na irighiri ihe.
- Lelee ma ọ bụrụ na ihe ịrịba ama ọ bụla nke mmebi anụ ahụ ma ọ bụ oke okpomọkụ.
- If the device is exposed to harsh environments, consider more frequent inspections.
ỊDỌ AKA NA NTỊ: Kwụpụ ike mgbe niile tupu ịmee mmezi ma ọ bụ nyocha ọ bụla.
7. Nchọpụta nsogbu
If the device is not functioning as expected, consider the following:
- No power to the load: Check the main power supply, circuit breaker, and all wiring connections. Ensure the device is receiving 230V.
- Timer not activating: Verify the input signal (e.g., from the push-button switch) is correctly connected and functioning.
- Incorrect timing duration: Re-check the setting on the 'T(min)' dial.
- ekpo oke ọkụ ngwaọrụ: Ensure the load current does not exceed 16A. Check for proper ventilation around the device.
If issues persist after checking these points, consult a qualified electrician or contact Finder customer support.
8. Nkọwapụta
| Njirimara | Nkọwapụta |
|---|---|
| Onye nrụpụta | Chọta |
| Nọmba nlereanya | 140182300000PAS |
| Akụkụ ngwaahịa (L x W x H) | 8.4 x 1.8 x 5.9 cm |
| Ibu | 60 grams |
| Agba | Agba ntụ |
| Ihe onwunwe | Plastic |
| Voltage | 230 volts |
| Ụdị kọntaktị | 1 NO (Normally Open) |
| Ogo dị ugbu a | 16 A |
| Ọnụọgụ nke Ntọala | 8 (Timer functions) |
| Batrị(ndị) dị n'ime ya | Mba |
| A chọrọ batrị(ndị) | Mba |
| Nnweta akụkụ mapụtara | Ozi adịghị |
8.1 Asambodo
The product complies with various international standards.

Foto 7: Product certifications, including CE, UKCA, EAC, and Q-Mark, indicating compliance with European, UK, Eurasian, and quality standards respectively.
9. Akwụkwọ ikike na nkwado
For warranty information and technical support, please refer to the official Finder websaịtị ma ọ bụ kpọtụrụ onye nkesa mpaghara gị. Debe nnata nzụta gị ka ihe akaebe nke ịzụrụ.