Schellenberg 25555

Schellenberg 25555 Zeitschaltuhr Plus User Manual

Brand: Schellenberg | Model: 25555

1. Okwu mmalite na gafereview

The Schellenberg 25555 Zeitschaltuhr Plus is an advanced, flush-mounted timer switch designed for the automated and convenient control of roller shutter motors. This device allows you to program daily and weekly schedules for your roller shutters, enhancing comfort, security, and energy efficiency in your home. Its user-friendly interface, featuring a large display and three intuitive buttons, ensures easy operation and programming.

This timer switch is compatible with Schellenberg STANDARD and PLUS tube motors and can be expanded with an optional sun sensor PLUS for additional automated functions.

2. Kedu ihe dị na Igbe ahụ

Upon unpacking your Schellenberg 25555 Zeitschaltuhr Plus, please ensure all the following components are present:

Schellenberg Zeitschaltuhr Plus product packaging

Image: The retail packaging of the Schellenberg Zeitschaltuhr Plus, showing the timer switch and indicating "Made in Germany" and "Optional Sensor."

3. Atụmatụ

The Schellenberg 25555 Zeitschaltuhr Plus offers a range of features designed for optimal roller shutter control:

N'ihu view of Schellenberg Zeitschaltuhr Plus timer switch

Foto: Ihe dị nso n'ihu view of the Schellenberg Zeitschaltuhr Plus, showing its digital display and three control buttons.

4. Ntọala na nwụnye

Installation of the Schellenberg Zeitschaltuhr Plus requires electrical work and should ideally be performed by a qualified electrician or a person with appropriate technical knowledge. Always ensure the main power supply to the circuit is switched off before beginning any installation work.

4.1. Nkwalite chọrọ

The timer switch is designed for flush-mounted installation in a standard electrical switch box. Ensure the switch box is adequately sized to accommodate the device and its wiring. The provided screws are for securing the unit within the flush-mounted box.

4.2. Ihe nkedo

Refer to the detailed wiring diagram provided in the comprehensive assembly and operating instructions included with your product. Incorrect wiring can lead to malfunction or electrical hazards. Pay close attention to the connections for power supply, motor control (up/down), and any optional sensor connections.

4.3. Ike Mmalite

After installation and wiring are complete, restore power to the circuit. The display should illuminate. You may need to set the current time and date as part of the initial setup process.

Schellenberg Zeitschaltuhr Plus installed controlling a roller shutter

Image: The Schellenberg Zeitschaltuhr Plus installed on a wall, demonstrating its use in controlling a roller shutter.

5. Ntuziaka ọrụ

The Schellenberg Zeitschaltuhr Plus is operated using its three front-facing buttons and the digital display. The exact sequence for programming may vary slightly, so always consult the included manual for precise steps.

5.1. Setting Current Time and Date

Upon initial power-up or after a prolonged power outage (beyond the 5-hour reserve), you will need to set the current time and day of the week. Use the designated buttons (typically up/down arrows or menu buttons) to navigate and adjust values, confirming with a central 'OK' or 'Set' button.

5.2. Ọrụ ntuziaka

The device allows for manual control of the roller shutters. Typically, dedicated buttons or a specific mode will enable you to open or close the shutters instantly, overriding any programmed schedules temporarily.

5.3. Programming Schedules (Daily/Weekly)

Access the programming menu to set specific opening and closing times for your roller shutters. You can usually set different times for each day of the week or apply a single schedule to all weekdays and another for weekends. The large display facilitates easy entry and review of these times.

5.4. Ọrụ Pụrụ Iche

6. Nlekọta

The Schellenberg Zeitschaltuhr Plus is designed for long-term, maintenance-free operation. Follow these guidelines to ensure its longevity:

7. Nchọpụta nsogbu

If you encounter issues with your Schellenberg Zeitschaltuhr Plus, consider the following common troubleshooting steps:

NsogbuIhe nwere ike imeNgwọta
Ngosipụta bụ oghere ma ọ bụ na ọ naghị enwu.Enweghị ọkụ ọkụ; ike gitage; internal fault.Check the circuit breaker. Verify power supply to the unit. If power is restored after an outage, the internal reserve should maintain settings for up to 5 hours. If still blank, consult a professional.
Roller shutter does not move according to program.Incorrect programming; manual override active; motor issue; sensor interference.Verify programmed times and days. Ensure the device is in automatic mode, not manual. Check if the random generator or sun/twilight function is active and overriding. Consult the motor's manual if the motor itself is unresponsive to manual commands.
Time or settings are lost after a power outage.Ike gitage exceeded the 5-hour power reserve.Reset the current time and reprogram any lost schedules. This is normal behavior if the power reserve is depleted.
Bọtịnụ anaghị anabata ya.Temporary software glitch; physical damage.Try briefly cutting power to the unit at the circuit breaker and then restoring it. If the issue persists, the unit may require professional inspection.

For more complex issues or if the above steps do not resolve the problem, please refer to the detailed troubleshooting section in your product's full instruction manual or contact Schellenberg customer support.

8. Nkọwapụta

NjirimaraNkọwa
ỤdịSchellenberg
Nọmba nlereanya25555
Akụkụ ngwaahịa5 x 2.5 x 5 cm (ihe dị ka 2 x 1 x 2 sentimita)
Ibu Ibu200g (ihe dị ka 0.44 lbs)
AgbaỌcha
Ike ReserveApprox. 5 hours (in case of power failure)
Oge mgbanweAutomatic summer/winter time adjustment
NdakọrịtaSchellenberg STANDARD and PLUS tube motors

9. Ozi nchekwa

Please read and adhere to all safety instructions to prevent injury or damage to the device:

Akwụkwọ ndị emetụtara - 25555

Tupuview Schellenberg Gurtführung Standard Mini: ⚠ Safety Instructions
Essential safety instructions and warnings for the Schellenberg Gurtführung mit Doppelleiterrolle Standard Mini (14mm belt width). Covers safe operation, child safety, and packaging hazards for roller shutter systems.
Tupuview Schellenberg ROLLOPOWER PLUS / STANDARD Roller Shutter Motor Installation Manual
Comprehensive installation and user manual for the Schellenberg ROLLOPOWER PLUS and STANDARD roller shutter motors, including model numbers, safety instructions, assembly steps, wiring diagrams, and end-position adjustment procedures.
Tupuview Schellenberg Rollladen-Gurtwickler Maxi Safety Instructions and Warnings
Read important safety precautions and warnings for the Schellenberg Rollladen-Gurtwickler Maxi (model 10425049) from Alfred Schellenberg GmbH. Ensure safe usage and handling.
Tupuview SCHELLENBERG Notentriegelungsschloss Modell 60611 Montagnke ọma
Montageanleitung für das SCHELLENBERG Notentriegelungsschloss, Modell 60611. Bietet detaillierte Anweisungen für die sichere und korrekte Installation dieses Sicherheitsgeräts.
Tupuview Schellenberg Controller 1 Kanal Bedienungsanleitung
Die Bedienungsanleitung für den Schellenberg Controller 1 Kanal (Modelle 20015/20019/20021/20022). Enthält wichtige Sicherheitshinweise, technische Daten, Montage- und Programmierungsanleitungen für Rollladenanlagen und Markisen.
Tupuview Schellenberg Funk-Codierschloss 60872: Montage- und Bedienungsanleitung
Detaillierte Anleitung für das Schellenberg Funk-Codierschloss Modell 60872. Erfahren Sie, wie Sie das Gerät installieren, PIN-Codes ändern und mit Garagentorantrieben koppeln. Mehrsprachig verfügbar.