1. Okwu mmalite
The Osram 70W HQI-TS Powerstar-Daylight lamp is a highly efficient metal halide lamp designed for use in enclosed luminaires. It provides excellent color rendition and a uniform distribution of light, making it suitable for various applications, including retail displays and environments requiring positive and welcoming illumination. This lamp features Powerstar quartz technology and UV filter technology, offering a long average life of 12,000 hours and hot restrike capability.
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Osram 70W HQI-TS Powerstar-Daylight R7s lamp.

Figure 1: Osram 70W HQI-TS Powerstar-Daylight R7s Lamp. This image shows the linear quartz metal halide lamp with its R7s base.
2. Ozi nchekwa
Na-edebe nchekwa nchekwa ndị a mgbe niile ka igbochi mmerụ ahụ ma ọ bụ mmebi ngwaahịa:
- Ensure power is disconnected before installation, removal, or maintenance.
- Nke a lamp requires a suitable ballast and igniter for operation. Do not connect directly to 230V mains supply.
- Only use in enclosed luminaires to prevent exposure to UV radiation and hot lamp fragments in case of rupture.
- Zere imetụ lamp with bare hands. Use a clean cloth or gloves during installation to prevent oil residue, which can cause hot spots and reduce lamp ndu.
- Kwe ka lamp ka ajụkwa kpamkpam tupu ejiri ya.
- Tụfuo ihe eji lamps dị ka iwu obodo si dị.
3. Ntọala na nwụnye
The Osram 70W HQI-TS Powerstar-Daylight lamp is designed for horizontal operation in R7s lamp holders within enclosed luminaires.
- Ịkwụsị ike: Ensure the power supply to the luminaire is completely disconnected before beginning installation.
- Luminaire Compatibility: Verify that your luminaire is designed for 70W metal halide lamps with an R7s base and is equipped with the correct ballast and igniter.
- Lamp Ijikwa: Jiri nlezianya wepụ ihe ọhụrụ lamp from its packaging. Hold the lamp by its ceramic ends or use a clean cloth/gloves to avoid touching the quartz envelope.
- Ntinye: Insert the R7s pins of the lamp into the corresponding lamp holder sockets. Ensure the lamp na-anọdụ ala na ntụkwasị obi.
- Mkpuchi: Close the luminaire enclosure securely. This lamp must only be operated in an enclosed fixture.
- Njikọ ike: Reconnect the power supply to the luminaire.
Mara: Incorrect installation or operation without the proper ballast and igniter can lead to lamp failure, fire hazard, or electric shock.
4. Ntuziaka ọrụ
Once installed correctly, operating the Osram 70W HQI-TS Powerstar-Daylight lamp dị mfe:
- Mgbanye mbido: Upon switching on, the lamp will ignite and gradually reach full brightness. This warm-up period typically takes approximately three minutes.
- Hot Restrike: Nke a lamp features hot restrike capability, meaning it can be re-ignited shortly after being switched off, without a prolonged cooling period.
- Agba ọkụ: This specific model provides a "Daylight" color temperature, ideal for applications requiring bright, natural-looking illumination. Other variants may offer Warm White (WDL), Neutral White (NDL), or Cool Daylight (CD) light.
- Arụmọrụ kacha mma: For optimal performance and lamp life, avoid frequent switching on and off.
5. Nlekọta
The Osram 70W HQI-TS Powerstar-Daylight lamp is designed for long-term, reliable operation with an average life of 12,000 hours. Minimal maintenance is required:
- Nhicha: Periodically clean the exterior of the luminaire and, if accessible and safe, the lamp itself with a soft, dry cloth to remove dust and debris. Ensure the power is off and the lamp is cool before cleaning.
- Ndochi: Dochie lamp when it reaches the end of its useful life (indicated by dimming, flickering, or failure to ignite). Always replace with a lamp nke otu ụdị na wattage.
- mkpofu: Dispose of old lamps responsibly according to local environmental regulations, as they may contain materials requiring special handling.
6. Nchọpụta nsogbu
If your Osram 70W HQI-TS Powerstar-Daylight lamp Ọ naghị arụ ọrụ dịka a tụrụ anya ya, tụlee nsogbu na ngwọta ndị a na-ahụkarị:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Lamp does not ignite. | No power supply, faulty lamp, faulty ballast/igniter, incorrect wiring. | Check power connection. Ensure lamp is correctly seated. Test with a known good lamp. Have a qualified electrician inspect ballast/igniter and wiring. |
| Lamp na-enwu enwu ma ọ bụ na-agbanyụ/gbanyụọ okirikiri. | Lamp nearing end of life, incorrect ballast, unstable power supply. | Dochie lamp. Verify ballast compatibility. Check power supply stability. |
| Reduced light output. | Lamp nearing end of life, dirty lamp/luminaire, incorrect wattage. | Dochie lamp. Clean lamp and luminaire. Ensure correct wattagelamp arụnyere. |
If troubleshooting steps do not resolve the issue, contact a qualified electrician or Osram customer support for assistance.
7. Nkọwapụta
Key technical specifications for the Osram 70W HQI-TS Powerstar-Daylight R7s lamp:
| Njirimara | Nkọwa |
|---|---|
| Ụdị | Osram |
| Nọmba nlereanya | 0800-0705o#1#fhu |
| Wattage | 70 watt |
| Ụdị ọkụ | Metal Halide (HQI-TS) |
| Isi Bulb | R7s, |
| Agba ọkụ | Ìhè ụbọchị |
| Voltage | 92 Volts (requires ballast) |
| Nkezi Ndụ | awa 12,000 |
| Atụmatụ pụrụ iche | Long Lasting, Powerstar quartz technology, UV filter technology, Hot Restrike Capability |
| Akụkụ ngwaahịa | 11.7 x 1.9 x 1.9 cm |
| Ibu | 17 g |
| Ojiji akọwapụtara | Suitable for outdoor and indoor use (in enclosed luminaires) |

Figure 2: Technical diagram illustrating the dimensions of the HQI-TS lamp. 'd' represents the diameter and 'a' represents the arc length or overall length depending on context.
8. Akwụkwọ ikike na nkwado
For warranty information or technical support regarding your Osram 70W HQI-TS Powerstar-Daylight R7s lamp, please refer to the official Osram websaịtị ma ọ bụ kpọtụrụ ngalaba ọrụ ndị ahịa ha. Debe nnata nzụta gị ka ihe akaebe nke ịzụrụ.
You can visit the official Osram store for more information: Osram Store