Bogen BG-C10

Bogen Classic C10 AmpAkwụkwọ ntuziaka onye ọrụ lifier

Model: BG-C10

1. Ngwaahịa gafereview

The Bogen Classic Series C10 Amplifier is designed to provide dependable audio performance and flexibility for various applications. This model is rated at 10 watts RMS output power and is UL and CSA listed, ensuring compliance with safety standards. It features discreet complementary transistor circuitry for maximum reliability of its power output stages.

C10 amplifier is part of a series that includes models with music-on-hold (MOH) output capabilities, though the C10 specifically focuses on amplification. It offers screw terminal connections for 600 Ohm 1 volt and 8 Ohm at 1 watt, along with a rear panel level control for easy adjustment.

Bogen Classic C10 Ampihu ihe mkpuchi view

Foto 1: N'ihu view of the Bogen Classic C10 Amplifier, showing the main controls and branding.

2. Atụmatụ

3. Ozi nchekwa

Please read and understand all safety instructions before operating this device. Failure to follow these instructions may result in electric shock, fire, or damage to the unit.

4. Ihe ngwugwu

Upon opening the package, verify that all components are present and in good condition. The standard package for the Bogen Classic C10 Amplifier typically includes:

If any items are missing or damaged, please contact your dealer or Bogen customer support immediately.

5. Nhazi

Follow these steps to set up your Bogen Classic C10 Ampntughari:

  1. Nkwanye: Debe ya amplifier on a stable, flat surface with adequate ventilation around the unit. Avoid placing it near heat sources or in direct sunlight.
  2. Njikọ Ọkà Okwu: Connect your speakers to the appropriate screw terminals on the rear panel. The C10 supports 8 Ohm at 1 watt speaker connections. Ensure correct polarity (+ to + and - to -) for optimal sound.
  3. Njikọ ntinye: Connect your audio source (e.g., mixer, pre-amplifier) to the input terminals. The amplifier provides screw terminal connections for 600 Ohm 1 volt input sources.
  4. Njikọ ike: Gbaa mbọ hụ na amplifier's power switch is in the OFF position. Connect the power cord to the amplifier's power inlet, then plug the other end into a suitable AC power outlet.
  5. Ntọala mbụ: Before powering on, ensure all volume/level controls on the amplifier are set to their minimum position to prevent sudden loud sounds.

6. Ntuziaka ọrụ

Ozugbo amplifier is set up, follow these steps for operation:

  1. Ike Na: Flip the power switch on the front panel to the ON position. The power indicator light should illuminate.
  2. Adjust Input Source: Ensure your audio source is playing.
  3. Adjust Level Control: Slowly increase the level control knob on the rear panel until the desired output volume is achieved. Avoid setting the level too high, which can cause distortion.
  4. Ndozi Treble: Use the treble equalizer control to fine-tune the high-frequency response of your audio.
  5. Gbanyụọ: When finished, turn the level control down, then flip the power switch to the OFF position.

7. Nlekọta

Proper maintenance ensures the longevity and optimal performance of your Bogen Classic C10 Ampna -emegharị ihe.

8. Nchọpụta nsogbu

If you encounter issues with your Bogen Classic C10 Amplifier, refer to the following troubleshooting guide:

NsogbuIhe nwere ike imeNgwọta
No Power / Power Indicator Off
  • Ejikọghị eriri ọkụ na nchekwa.
  • Ọwa ọkụ anaghị arụ ọrụ.
  • Igwe ọkụ dị n'ime fụrụ.
  • Check power cord connections at both amplifier and wall outlet.
  • Jiri ngwaọrụ ọzọ nwalee ọpụpụ.
  • Contact qualified service personnel for fuse replacement.
Enweghị mpụta ụda
  • Input source not playing or connected incorrectly.
  • Speaker connections loose or incorrect polarity.
  • Level control set too low.
  • Faulty speaker.
  • Verify input source is active and connected correctly.
  • Check all speaker wire connections and polarity.
  • Slowly increase the level control.
  • Test with a different speaker.
Ụda agbagọ
  • Level control set too high.
  • Mgbaàmà ntinye siri ike nke ukwuu.
  • Mgbochi okwu na-ezighi ezi.
  • Damaged speaker or cable.
  • Reduce the level control.
  • Lower the output level from the input source.
  • Ensure speakers match the amplifier's impedance requirements (8 Ohm).
  • Inspect speakers and cables for damage.

If the problem persists after trying these solutions, please contact Bogen customer support or a qualified service technician.

9. Nkọwapụta

NjirimaraUru
ỤdịBogen
Nọmba nlereanyaBG-C10
Ike Mmepụta RMS10 W
Eji ike arụ ọrụ38 W
Nzaghachi ugboro kacha nta70 Hz
Nzaghachi ugboro ugboro kacha16 kHz
Mgbagwoju anya Harmonic Distortion (THD)1%
Ụdị nha nhataTreble
Ibu Ibu4.85 pound
Akụkụ ngwaahịa13.75 x 10.25 x 5.25 sentimita asatọ
Onye nrụpụtaBOGEN

10. Akwụkwọ ikike na nkwado

Bogen Communications International, Inc. provides a limited warranty for its products. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Bogen websaịtị.

For technical support, service, or inquiries regarding your Bogen Classic C10 Amplifier, please contact Bogen customer support through their official channels. Have your model number (BG-C10) and serial number (if applicable) ready when contacting support.

Akụrụngwa dị n'ịntanetị: For additional information, FAQs, and product updates, visit the official Bogen websaịtị.

Akwụkwọ ndị emetụtara - BG-C10

Tupuview Bogen NQ-GA20P2 Nyquist Integrated Power Amplifier Configuration Manual
Configuration guide for the Bogen NQ-GA20P2 Nyquist 20-watt integrated power amplifier, covering setup, network settings, firmware updates, and DSP parameter adjustments.
Tupuview Bogen CC4041 CC Series Amplifier Installation and Use Manual
Installation and use manual for the Bogen CC4041 CC Series Amplifier, detailing its features, connections, operation, safety instructions, and technical specifications.
Tupuview Bogen BPA60 Power Amplifier Installation & Use Manual
Comprehensive installation and usage guide for the Bogen BPA60 60-watt mono-channel power amplifier, detailing technical specifications, safety precautions, connection diagrams, operation instructions, and warranty information.
Tupuview Bogen Platinum Series PS240-G2, PS120-G2 Public Address Amplifier Installation and Use Guide
Comprehensive installation and use guide for the Bogen Platinum Series PS240-G2 and PS120-G2 public address amplifiers, detailing features, panel descriptions, connections, operation, troubleshooting, and technical specifications.
Tupuview Bogen TPU Series Telephone Paging Amplifiers: Installation and Use Manual
Comprehensive installation and use manual for Bogen TPU35B, TPU60B, TPU100B, and TPU250 telephone paging amplifiers, covering setup, wiring, operation, and specifications.
Tupuview Bogen ike Vector Amplifiers V35, V60, V100, V150, V250 Installation and Use Manual
Comprehensive installation and use manual for Bogen Power Vector Amplifiers (Models V35, V60, V100, V150, V250), covering panel descriptions, installation, modules, connections, operation, specifications, troubleshooting, warranty, and accessories.