1. Okwu mmalite
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Red Lion RL-WC50TA Cast Iron Sewage Pump. Please read all instructions carefully before use to ensure proper function and longevity of the product.
The Red Lion RL-WC50TA is a robust 1/2 HP submersible pump designed for high-volume transfer of sewage or effluent. It is capable of handling semi-solids up to 2 inches in diameter, making it suitable for applications such as basement washrooms, sewage systems, or holding tanks. This pump is equipped with a piggyback tethered float switch for automatic operation.
Important: This pump is not recommended for pond use.
2. Ozi nchekwa
Always prioritize safety during installation, operation, and maintenance. Failure to follow safety guidelines can result in serious injury or property damage.
- Nchekwa Eletriki: Ensure the power supply matches the pump's requirements (115 Volts). Always disconnect power before servicing the pump. Use a ground fault circuit interrupter (GFCI) for electrical connections.
- Ngwa nchekwa nkeonwe (PPE): Wear appropriate PPE, including gloves and eye protection, when handling the pump or working with wastewater.
- Nwụnye nke ọma: Install the pump according to local plumbing and electrical codes. Ensure the pump is placed on a solid, level surface in the basin.
- Ngwa ndị dị ize ndụ: Be aware that sewage and effluent contain hazardous biological materials. Avoid direct contact and ensure proper disposal.
- Ụmụaka na anụ ụlọ: Keep children and pets away from the pump and installation area.
3. Ngwaahịa gafereview
The Red Lion RL-WC50TA is engineered for durability and reliable performance in demanding wastewater applications.

Figure 1: Red Lion RL-WC50TA Cast Iron Sewage Pump with tethered float switch.
Akụkụ ndị bụ isi:
- Ịrụ Ọrụ Dị arọ: Cast iron housing and vortex-style impeller for durability and efficient solids handling.
- Ijikwa siri ike: Capable of passing semi-solids up to 2 inches in diameter, preventing clogs.
- Ọrụ akpaaka: Piggyback tethered float switch for automatic activation and deactivation based on water levels.
- Nchekwa moto: 1/2 HP PSC dual bearing motor with thermal overload protection for extended life.
- CSA Listed: Certified for safety in both USA and Canada.
Ngwa ime:

Figure 2: Diagram illustrating the internal components of the RL-WC50TA, including the 1/2 HP high-efficiency PSC motor with thermal overload protection, dual ball bearings, cast iron housing, stainless steel rotor shaft, cast iron vortex style impeller, and 2-inch FNPT threaded discharge.
4. Ntọala na nwụnye
Proper installation is critical for the performance and safety of your sewage pump. If you are unsure about any step, consult a qualified professional.
Ndepụta nwụnye tupu etinyere:
- Verify power supply (115 Volts).
- Gbaa mbọ hụ na basin diameter is at least 18 inches.
- Gather necessary tools and plumbing fittings (2-inch FNPT discharge).
- Confirm the installation area is clear and accessible.
Nzọụkwụ nwụnye:
- Prepare the Basin: Hụ na sump ahụ basin is clean and free of debris. The pump should rest on a solid, level surface at the bottom of the basin.
- Jikọọ na ọkpọkọ mwepụta: Attach a 2-inch FNPT discharge pipe to the pump outlet. Use appropriate sealant or tape to ensure a watertight connection.
- Install Check Valve: Install a check valve in the discharge line above the pump to prevent backflow of water into the basin.
- Debe mgbapụta ahụ: Carefully lower the pump into the basin. Ensure the float switch can move freely without obstruction from the pump, basin walls, or piping.
- Njikọ eletrik: Connect the pump's 10-ft. power cord to a dedicated 115 Volt, GFCI-protected outlet. The piggyback plug allows for automatic or manual operation.
Understanding Pump Types (Video):
For a better understanding of different pump types and their applications, including sewage and effluent pumps, please watch the following informational video:
Video 1: This video explains the differences between sump, sewage, effluent, and utility pumps, helping users understand the correct application for each type. Provided by Franklin Electric - Little Giant.
5. Ntuziaka ọrụ
The Red Lion RL-WC50TA operates automatically via its tethered float switch. It can also be manually tested.
Ọrụ akpaaka:
- The pump will activate when the water level reaches approximately 17.5 inches.
- The pump will continue to run until the water level falls to approximately 7.5 inches, at which point it will shut off.
- Ensure the float switch has a clear path of travel and is not restricted by any objects in the basin.

Figure 3: Illustration of the piggyback float switch and its activation/deactivation levels for automatic operation. The piggyback plug allows for switching to manual mode for testing or maintenance.
Manual Operation/Testing:
The piggyback plug design allows for manual testing of the pump. To operate manually, simply unplug the float switch plug from the wall outlet, then plug the pump's main power cord directly into the wall outlet. The pump will run continuously. To return to automatic operation, unplug the pump's main power cord and re-insert the float switch plug into the wall outlet.
Caution: Do not run the pump dry for extended periods in manual mode, as this can cause damage.
6. Nlekọta
Nlekọta anya mgbe niile na-eme ka arụmọrụ dị mma ma gbasaa ndụ nke mgbapụta gị.
- Nnyocha kwa ọnwa: Check the sump basin for excessive debris. Remove any large objects that could obstruct the float switch or pump intake.
- Float Switch Check: Periodically test the float switch by manually raising it to ensure the pump activates and deactivates correctly.
- Igwe ọkụ dị ọcha: If the pump's performance decreases, disconnect power and inspect the impeller for clogs or buildup. Clean as necessary.
- Nyocha eriri ike: Examine the power cord for any signs of damage, fraying, or wear. Replace if damaged.
- Oge oyi (ọ bụrụ na ọdabara): Ọ bụrụ na ọkpọkọ ahụ dị n'ebe oyi na-atụ ma agaghị eji ya, wepụ ya na basin, clean it thoroughly, and store it in a dry, frost-free location.
7. Nchọpụta nsogbu
Rụtụ aka na tebụl dị n'okpuru maka okwu nkịtị na ihe ngwọta ha nwere ike ime.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Mgbapụta anaghị agba ọsọ | Enweghị ike; onye na-agbaji agbaji; mgba ọkụ n'elu mmiri na-ezighi ezi; impeller kpuchiri ekpuchi | Check power supply and breaker; test float switch; clear impeller |
| Mgbapụta ọkụ na-aga n'ihu | Float switch stuck in ON position; faulty float switch | Check float switch for obstructions; replace float switch if faulty |
| Pampụ na-agba mana mmiri anaghị apụta | Clogged intake or discharge pipe; air lock; low water level | Clear clogs; prime pump if air locked; ensure sufficient water level |
| Pump cycles kwa ugboro | Basin too small; check valve not holding; float switch differential too narrow | Consult a professional for basin size; inspect/replace check valve; adjust float switch if possible (refer to specifications) |
8. Nkọwapụta
Detailed technical specifications for the Red Lion RL-WC50TA Sewage Pump.

Figure 4: Dimensions diagram for the Red Lion RL-WC50TA Sewage Pump. Height (A): 15.8" (401 mm), Length (B): 9" (229 mm), Width (C): 6" (152 mm), Weight: 30 lbs (13.6 kg).
| Nkọwapụta | Uru |
|---|---|
| Nlereanya | RL-WC50TA |
| Nọmba akụkụ | 14942748 |
| Ụdị | Red Lion |
| Ịnyịnya ike (HP) | 0.5 (1/2 HP) |
| Voltage | 115 volts |
| Ampoge | 9 Amps |
| Wattage | 950 watt |
| Ọnụego nfe kacha | 5600 GPH (Galọn 93 kwa nkeji) |
| Maximum Lifting Height (Shutoff) | 22 ụkwụ |
| Ihapu Size | 2-inch FNPT |
| Ijikwa Solids | Up to 2-inch diameter semi-solids |
| Ụdị Mgbanwe Float | Piggyback Tethered |
| Float Switch ON Level | 17.5 sentimita asatọ |
| Float Switch OFF Level | 7.5 sentimita asatọ |
| Ogologo eriri ike | 10 ụkwụ |
| Minimum Basin Dayameta | 18 sentimita asatọ |
| Ihe onwunwe | Nkedo Ígwè |
| Akụkụ ngwaahịa (L x W x H) | 9" x 6" x 15.8" |
| Ibu Ibu | 29.8 pound |

Figure 5: Performance curve and table for the Red Lion RL-WC50TA, showing Gallons Per Hour (GPH) at various lift heights and the shut-off point.
9. Akwụkwọ ikike
The Red Lion RL-WC50TA Sewage Pump comes with a Akwụkwọ ikike onye nrụpụta afọ 2. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty documentation included with your product or contact Red Lion customer support.
10. Nkwado
For technical assistance, product inquiries, or warranty support, please contact Red Lion customer service. You can also visit the official Red Lion websaịtị maka akụrụngwa ndị ọzọ na FAQ.
- Red Lion Websaịtị: Visit the Red Lion Store on Amazon
- Nkwado ndị teknuzu: Refer to your product packaging or the Red Lion websaịtị maka ozi kọntaktị kacha ugbu a.