Banner QS30AFQ

Banner QS30AFQ World Beam Expert Universal Sensor

Akwụkwọ ntuziaka

Model: QS30AFQ

1. Okwu mmalite

This manual provides detailed instructions for the installation, operation, and maintenance of the Banner QS30AFQ World Beam Expert Universal Sensor. The QS30AFQ is an advanced photoelectric sensor designed for industrial automation applications, featuring adjustable-field background-suppression mode and a visible red LED sensing beam.

It is equipped with both automatic-teaching and manual tuning modes, and provides bipolar (NPN and PNP) output. Its robust design ensures reliable performance in various environments, including those with moisture and dust.

2. Ozi nchekwa

Please read and understand all instructions before installing or operating the sensor. Failure to follow these instructions could result in serious injury or damage to the equipment.

  • Nchekwa Eletriki: Ensure power is disconnected before wiring or performing any maintenance. Only qualified personnel should perform electrical connections.
  • Ọnọdụ gburugburu: Do not expose the sensor to conditions outside its specified operating temperature or IP rating.
  • Ịkwanye: Securely mount the sensor to prevent accidental dislodgement during operation.
  • Ezubere iji: This sensor is designed for industrial automation applications. Do not use it for safety-critical applications unless specifically certified for such use.

3. Ngwaahịa gafereview

The Banner QS30AFQ sensor is a compact and versatile photoelectric sensor. Key features include:

  • Adjustable-field background-suppression mode for reliable detection up to 300 mm.
  • Visible red LED sensing beam (660 nm wavelength) for easy alignment.
  • 5-pin Euro-style Quick Disconnect (QD) connector for convenient wiring.
  • Automatic tuning with pushbutton manual fine tuning options.
  • 10-30 VDC supply voltage.
  • Bipolar (NPN and PNP) output.
  • IP 67 rated thermoplastic housing for protection against water and dust.
  • 8-segment bar graph display for operating status indication.
N'ihu view of the Banner QS30AFQ sensor showing the red LED lens and setting labels.
Foto 3.1: N'ihu view of the QS30AFQ sensor, highlighting the visible red LED lens and the labels for setting background and object detection thresholds. This view shows the primary sensing face of the unit.
Akụkụ view of the Banner QS30AFQ sensor showing the wiring diagram, bar graph display, and control buttons.
Foto 3.2: Akụkụ view of the QS30AFQ sensor, displaying the wiring diagram for the 5-pin Euro-style connector, the 8-segment bar graph indicator, and the '+' and '-' control buttons for tuning. This view provides details on electrical connections and operational feedback.

4. Nhazi

4.1 Na-arịgo

The QS30AFQ sensor can be mounted using standard mounting hardware (not included) through the integrated mounting holes. Ensure the sensor is securely fastened and positioned to provide an unobstructed view of the target area. The sensor's compact design allows for flexible mounting in various industrial setups.

4.2 Waya

The sensor utilizes a 5-pin Euro-style Quick Disconnect (QD) connector. A compatible Euro-style QD cordset (not included) is required for connection. Refer to the wiring diagram on the sensor body (Figure 3.2) and the table below for proper connections.

Table 4.1: Wiring Connections for QS30AFQ
Agba pin/ wayaỌrụ
Brown (bn)10-30 VDC Supply (+)
Blue (bu)0 VDC Supply (-)
Ọcha (wh)NPN mmepụta
Nwa (bk)Mpụta PNP
Grey (gy)Ntinye nkuzi ime ime

Ensure all connections are secure and correctly polarized. The sensor supports bipolar (NPN and PNP) output, allowing flexibility in integration with various control systems.

5. .rụ ọrụ

5.1 Na-agbanye ike

Once wired correctly, apply 10-30 VDC power to the sensor. The sensor will power up and the 8-segment bar graph display will illuminate, indicating its operational status.

5.2 Tuning and Configuration

The QS30AFQ offers both automatic-teaching and manual tuning modes to set sensing thresholds.

  • Automatic Teaching: This mode simplifies setup. To teach the background, ensure no object is in the sensing field and press and hold the '+' button (or activate the remote teach input) until the sensor indicates successful teaching (refer to the bar graph display for feedback). To teach the object, place the object in the desired sensing position and press and hold the '-' button (or activate the remote teach input) until the sensor indicates successful teaching.
  • Manual Fine Tuning: After automatic teaching, or for precise adjustments, use the '+' and '-' buttons to manually fine-tune the sensing threshold. The 8-segment bar graph display provides visual feedback on the current threshold setting and signal strength.

5.3 Ngosipụta ọnọdụ

The 8-segment bar graph display on the side of the sensor provides real-time feedback on the sensor's operation:

  • Segments 1-8: Indicate signal strength. More illuminated segments mean stronger signal.
  • N.O. (Normally Open) / N.C. (Normally Closed) Indicators: Show the current state of the NPN and PNP outputs.
  • Object / Background Indicators: Help visualize the taught thresholds for object and background detection.

6. Nlekọta

The Banner QS30AFQ sensor is designed for low maintenance. However, periodic checks can ensure optimal performance and longevity.

  • Nhicha: Regularly clean the sensor lens and housing with a soft, damp cloth. Avoid abrasive cleaners or solvents that could damage the thermoplastic material or lens.
  • Nyocha: Periodically inspect the wiring and connector for any signs of wear, corrosion, or damage. Ensure the sensor is still securely mounted.
  • Nyocha gburugburu: Verify that the operating environment remains within the specified temperature range (-10 to +55 degrees C) and that the IP67 rating is not compromised by excessive moisture or dust accumulation on the lens.

7. Nchọpụta nsogbu

If the sensor is not performing as expected, consider the following common issues and solutions:

  • No Power/No Indication:
    • Check power supply connections (10-30 VDC).
    • Verify correct wiring of the Euro-style QD cordset.
  • Erratic Sensing/False Triggers:
    • Hichaa oghere ihe mmetụta.
    • Re-perform the automatic teaching procedure for background and object.
    • Adjust the sensor's position or angle to minimize reflections from nearby surfaces.
    • Check for ambient light interference; reposition or shield the sensor if necessary.
  • Sensor Not Detecting Object:
    • Ensure the object is within the 300 mm sensing range.
    • Verify the object's reflectivity is sufficient for detection by a red LED sensor.
    • Re-teach the object and background thresholds.
    • Check for obstructions in the sensing path.
  • Output Not Switching:
    • Confirm the load connected to the NPN/PNP output is correctly wired and within the sensor's output current limits.
    • Check the sensor's status indicators to ensure it is detecting the object as expected.

If problems persist, contact Banner Engineering technical support.

8. Nkọwapụta

Table 8.1: Banner QS30AFQ Technical Specifications
OkeUru
Nọmba nlereanyaQS30AFQ
Ụdị mmetụtaAdjustable-Field Background-Suppression
Oke nghọtaRuo 300 mm
Isi Iyi ÌhèVisible Red LED (660 nm)
Tụkwasịnụ Voltage10-30 VDC
Ụdị mmepụtaBipolar (NPN and PNP)
Ụdị njikọ5-pin Euro-style Quick Disconnect (QD)
Okpomọkụ na-arụ ọrụ-10°C ruo +55°C (14°F ruo 131°F)
Ihe eji eme ụlọThermoplastic
Nleba Nchedo (IP).IP67
Akụkụ0.31 x 0.31 x 0.24 sentimita (ihe dị ka)
Ibu0.16 ounces (ihe dị ka)
AsambodoUL Listed, CE Compliant

9. Akwụkwọ ikike na nkwado

For detailed warranty information, please refer to the official Banner Engineering website or contact your authorized Banner distributor. Warranty terms typically cover defects in materials and workmanship under normal use.

For technical support, troubleshooting assistance beyond this manual, or inquiries about replacement parts, please contact Banner Engineering customer service or visit their official support portal. Provide your product model number (QS30AFQ) and a detailed description of the issue when seeking support.

Banner Engineering Contact Information:
Biko rụtụ aka www.bannerengineering.com maka nkọwa kọntaktị kachasị ọhụrụ na akụrụngwa nkwado.

Akwụkwọ ndị emetụtara - QS30AFQ

Tupuview Banner M12 X-Code 8-Pin Field Wireable Connector Datasheet and Assembly Guide
Nkọwa zuru ezu, ngwaahịa agwụlaview, and assembly instructions for the Banner M12 X-Code 8-Pin Field Wireable Connector, designed for industrial Ethernet Category 6a applications. Includes construction details, environmental ratings, and warranty information.
Tupuview Banner BCS1 Miniature Slot Sensors: Features, Specifications, and Applications
Explore the Banner BCS1 Miniature Slot Sensors. Discover their simple, space-saving design, robust IP64 housing, bright LED indicators, and built-in circuit protection. View specifications, wiring diagrams, and available accessories.
Tupuview Banner R58E Expert Registermarkensensoren - Technische Daten und Konfiguration
Umfassende Informationen zu den Banner R58E Expert Registermarkensensoren, einschließlich Funktionen, Modellen, Konfigurationsanleitungen (TEACH, SETUP), technischen Spezifikationen und Installationshinweisen für industrielle Anwendungen.
Tupuview Ọkọlọtọ JB-4M12-M23 Mgbochi Njikọ: atụmatụ, nkọwapụta na ntuziaka wiring
Nyochaa ọkọlọtọ JB-4M12-M23 usoro nkwụsịtụ ngọngọ, ihe ngwọta ọdụ ụgbọ mmiri 4 siri ike emebere iji mee ka wiwi ụlọ ọrụ dị mfe na njikọta. Ntuziaka a na-akọwapụta atụmatụ ya, ụdị dị (NPN, PNP, Discrete), nkọwa dị mkpa na ngwa dakọtara maka akpaaka dị mma.
Tupuview Banner R58E Series Expert Registration Mark Sensor Datasheet
Datasheet for the Banner R58E Series Expert Registration Mark Sensor, featuring a tri-color light source, fast 10 kHz switching frequency, advanced TEACH modes (Static and Dynamic), and robust construction for industrial applications.
Tupuview Banner B25 Wide Beam Retroreflective Sensor: Product Manual & Specifications
Detailed product manual for the Banner B25 Wide Beam Retroreflective Sensor, covering installation, configuration, specifications, accessories, and support. Learn about its features for reliable target detection.