1. Ngwaahịa gafereview

The Sicce Ultrazero Flat Sucking Pump is designed for efficient removal of water from various areas, including flooded cellars, garages, and other spaces where minimal residual water is desired. This submersible pump is capable of reducing water levels down to 2-3 mm.

Akụkụ ndị bụ isi:

  • Capable of pumping water down to 2 mm residual level.
  • Fully submersible design.
  • Handles dirt particles up to 3 mm in size.
  • Equipped with a 10-meter power cable.
  • Features a practical carry handle for easy transport.
Sicce Ultrazero Flat Sucking Pump

Nyocha 1: N'eluview of the Sicce Ultrazero Flat Sucking Pump.

2. Ozi nchekwa

Read all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Kwụpụ pampụ ahụ mgbe niile na ọkụ eletrik tupu ị na-ejikwa ya, hichaa ya, ma ọ bụ na-arụzi ya nke ọma.
  • Gbaa mbọ hụ na ọkọnọ ọkụ voltage matches the pump's specifications (230 V/50 Hz).
  • Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
  • Do not use the pump to handle flammable or explosive liquids.
  • Debe ụmụaka na ndị na-enyeghị ikike ka ha ghara ịnọ ebe a na-arụ ọrụ.
  • Ensure the pump is fully submerged during operation to prevent overheating.
  • Avoid running the pump dry for extended periods.
  • This pump is designed for water only. Do not use it for other liquids without consulting the manufacturer.

3. Ntọala na nwụnye

Follow these steps to properly set up your Ultrazero pump:

  1. Wepu mgbapụta ahụ: Jiri nlezianya wepụ ọkpọkọ ahụ na ihe niile dị na ngwugwu ahụ. Lelee ma ọ bụrụ na ihe ọ bụla mebiri emebi.
  2. Connect the Discharge Hose:

    The pump features a 26.44 mm (3/4") AG pressure connection. Attach a suitable discharge hose (e.g., 20 mm (3/4") hose connection) to this outlet. Ensure the connection is secure to prevent leaks.

    Pump outlet and handle

    Figure 2: Close-up of the pump's discharge outlet and integrated carry handle.

  3. Debe mgbapụta ahụ: Place the pump directly on the surface from which water needs to be removed. Ensure the pump is stable and upright. The flat base allows for efficient water removal down to minimal levels.
  4. Route the Discharge Hose: Direct the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained.
  5. Njikọ ike: Plug the 10-meter power cable into a grounded 230 V/50 Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.
Isi mgbapụta

Figure 3: The flat base of the pump designed for low residual water levels.

4. Ntuziaka ọrụ

The Ultrazero pump is designed for simple operation:

  1. Weba Pump ahụ: Ensure the pump is fully submerged in the water you wish to remove. The pump requires water to cool its motor and operate correctly.
  2. Malite ịgbapụta mmiri: Once submerged and connected to power, the pump will begin operating automatically. It does not feature a float switch, so manual monitoring is required for optimal use.
  3. Nyochaa Ọkwa Mmiri: The pump will continue to operate until the water level reaches its minimum suction capability of 2-3 mm.
  4. Stop Pumping: To stop the pump, disconnect it from the power supply. It is recommended to disconnect the pump once the desired water level is reached or if the pump starts to run dry.
Pump draining a small pool

Figure 4: The Ultrazero pump effectively draining water from a small pool.

Pump draining a flooded floor

Figure 5: The pump in action on a flooded floor, demonstrating its low-level suction capability.

Pump showing 2mm residual water level

Figure 6: Illustration of the pump's ability to reduce water levels to approximately 2 mm.

5. Nlekọta

Regular maintenance ensures the longevity and optimal performance of your pump.

  • Nhicha: After each use, especially when pumping dirty water, rinse the pump thoroughly with clean water. This helps prevent sediment buildup.
  • Lelee maka irighiri ihe: Periodically check the pump's intake area for any debris (e.g., leaves, small stones) that might obstruct water flow. Remove any blockages carefully after disconnecting power.
  • Nyocha USB: Regularly inspect the power cable for cuts, abrasions, or other damage. Do not use the pump if the cable is damaged.
  • Nchekwa: When not in use, store the pump in a clean, dry place, protected from frost.
Pump used for garden watering

Figure 7: The pump can also be used for transferring water for tasks like garden watering from a rain barrel.

6. Nchọpụta nsogbu

If you encounter issues with your Ultrazero pump, refer to the following common problems and solutions:

NsogbuIhe nwere ike imeNgwọta
Mgbapụta anaghị ebido.Enweghị ọkụ.
Igwe ọkụ mebiri emebi.
Emere ka nchekwa ibu arọ nke moto rụọ ọrụ.
Lelee njikọ ọkụ na ọpụpụ.
Inspect cable for damage; replace if necessary (by qualified personnel).
Disconnect power, allow motor to cool, then reconnect.
Pump runs but no water is discharged.Intake blocked.
A gbagọrọ agbagọ ma ọ bụ kpọchie paịpụ mmiri.
Airlock in pump.
Disconnect power, clear intake.
Lelee ma hichaa paịpụ mmiri na-apụ apụ.
Briefly lift and lower the pump while submerged to release trapped air.
Reduced pumping performance.Partial blockage.
Impeller worn.
Disconnect power, clean pump intake and impeller area.
Kpọtụrụ nkwado ndị ahịa maka ọrụ.
Mgbapụta na-akwụsị na mberede.Overheating due to low water level or blockage.
Mmejọ eletrik.
Disconnect power, check water level and clear blockages. Allow to cool.
Ọ bụrụ na nsogbu dị, kpọtụrụ nkwado ndị ahịa.

If the problem persists after attempting these solutions, please contact Sicce customer support.

7. Nka na ụzụ nkọwa

Detailed specifications for the Sicce Ultrazero Flat Sucking Pump, Model 925607:

NkọwapụtaUru
ỤdịSicce
Nọmba nlereanya925607
Max. Delivery Rate (Flow Rate)3000 l/h
Oke. Ogologo nnyefe3.1 m
Power Consumption (P1)80 W
Nrụ ọrụ Voltage220-240 V / 50 Hz
Conductor Length (Power Cable)10 m (three-core, indoor and outdoor use)
Njikọ nrụgide26.44 mm (3/4") AG
Dayameta Njikọ Paịpụ20 mm (3/4")
Max. Solids Size3 mm
Ọkwa mmiri fọdụrụnụDown to 2-3 mm
Akụkụ ngwaahịa (ihe dị ka)140 mm (Diameter) x 160 mm (Height) / 5.5" x 6.3"
Ibu Ibu2.6 n'arọ (5.72 lbs)
N'elu mmiri GbanyeMba
Nchekwa oke ibuNo (Internal thermal protection may exist, but no external reset)
MmaliteEmere na Italy
Technical drawing with pump dimensions

Figure 8: Technical drawing illustrating the pump's dimensions and 3/4" GAS connection.

8. Akwụkwọ ikike na nkwado

For warranty information or technical support regarding your Sicce Ultrazero Flat Sucking Pump, please contact Sicce customer service. Keep your purchase receipt and model number (925607) handy when contacting support.

Onye nrụpụta: Ebara

Akara: Sicce

For further assistance, visit the official Sicce websaịtị ma ọ bụ kpọtụrụ onye nkesa mpaghara gị.

Akwụkwọ ndị emetụtara - 925607

Tupuview Akwụkwọ ntuziaka SICCE ULTRA 9000 Multifunction Pump Ntuziaka
Akwụkwọ ntuziaka zuru oke maka SICCE ULTRA 9000 multifunction submersible pump, mkpuchi mkpuchi, nrụnye, ojiji, mmezi na ozi akwụkwọ ikike.
Tupuview Akwụkwọ ntuziaka nrụnye SICCE Master DW Pump
Akwụkwọ ntuziaka a na-enye ntụziaka maka nrụnye, ojiji, mmezi, na nchekwa nchekwa maka mgbapụta SICCE Master DW, nke kwesịrị ekwesị maka ịmepụta ihe mmiri, isi iyi, na drainage. Ọ na-ekpuchi ụkpụrụ nchekwa, usoro ọrụ, usoro mmezi, ozi akwụkwọ ikike na mkpofu kwesịrị ekwesị.
Tupuview SICCE Syncra Nano Aquarium Pump - ntuziaka ntuziaka
Akwụkwọ ntuziaka maka SICCE Syncra Nano aquarium pump, na-akọwapụta nchekwa, nrụnye, ojiji, mmezi na akwụkwọ ikike. Kwesịrị ekwesị maka aquarium mmiri dị ọhụrụ na nke nnu, isi iyi ndị a na-achọ mma, protein skimmers, na usoro mmiri oyi.
Tupuview SICCE Mimouse Aquarium Pump - Akwụkwọ ntuziaka
Akwụkwọ a na-enye ntụzịaka zuru oke maka SICCE Mimouse aquarium na mgbapụta mmiri, na-ekpuchi ụkpụrụ nchekwa dị mkpa, ojiji, usoro mmezi na ozi akwụkwọ ikike.
Tupuview SICCE SCUBA PRESET Aquarium Heater: Safety, Operation, and Warranty Guide
Comprehensive guide for the SICCE SCUBA PRESET submersible aquarium heater, covering essential safety instructions, operating procedures, maintenance tips, warranty information, and technical specifications for optimal aquarium temperature control.
Tupuview Sicce SCUBA CONTACTLESS Aquarium Heater - User Manual and Safety Instructions
Comprehensive guide for the Sicce SCUBA CONTACTLESS submersible electronic aquarium heater. Learn about safety instructions, operating procedures, maintenance, and warranty information. This heater requires a NFC-enabled smartphone for temperature control via the ContrALL app.