Altronix PD4

Akwụkwọ ntuziaka onye ọrụ nke Modulu Nkesa Ike Altronix PD4

Nlereanya: PD4

1. Okwu mmalite

The Altronix PD4 is a power distribution module designed to efficiently manage power delivery. It converts a single AC or DC input into four (4) individually fuse-protected outputs. This module is suitable for various low-voltage applications requiring reliable power distribution and circuit protection.

2. Ozi nchekwa

Please read and understand all instructions before installing or operating the Altronix PD4. Failure to follow these instructions may result in injury or damage to the device.

3. Atụmatụ

4. Nkọwapụta

NkọwapụtaUru
Ntinye Voltage12-24VDC
Mkpokọta mpụta ugbu a10A (kachasị)
Ọnụọgụ nke mmepụta4 (individually fused)
Akụkụ ngwaahịa3.4 x 1.75 x 5.9 sentimita asatọ
Ibu Ibu1 pound
Nọmba nlereanyaPD4
Onye nrụpụtaAltronix Corporation

5. Ntọala na nwụnye

Before proceeding, ensure all power is disconnected from the input source.

5.1. Ịkwanye

The PD4 module can be mounted using screws through the designated mounting holes on the board. Choose a secure, dry location with adequate ventilation.

5.2. Njikọ njikọ

  1. Ike ntinye: Connect the 12-24VDC power source to the input terminals labeled 'MAIN FUSE' or similar input terminals. Observe correct polarity (positive to positive, negative to negative).
  2. Ngwa mmepụta: Connect your devices requiring power to the four (4) output terminal pairs (1P/1N, 2P/2N, 3P/3N, 4P/4N). Each output is individually protected by a fuse. Ensure the total current draw for all connected devices does not exceed 10A.
  3. Nwụnye fiusi: Insert the appropriate fuses into the designated fuse holders for each output. Refer to the markings on the board for recommended fuse ratings.
Altronix PD4 Power Distribution Module board, top view

Figure 1: Altronix PD4 Power Distribution Module board, top view. Shows the main fuse holder, four sets of output terminals, and fuse locations for each output.

Altronix PD4 Power Distribution Module board, angled view

Figure 2: Altronix PD4 Power Distribution Module board, angled view. Highlights the terminal blocks for input and output connections, along with the fuse holders.

5.3. Ike Up

Once all connections are secure and fuses are in place, apply power to the input terminals. The power indicator LED (if present) on the board should illuminate, indicating proper power input.

6. Ntuziaka ọrụ

The Altronix PD4 operates automatically once power is supplied. It distributes the input power to the four connected output devices, with each output protected by its respective fuse. There are no user-adjustable settings or controls on the module itself beyond the initial wiring and fuse selection.

7. Nlekọta

The Altronix PD4 requires minimal maintenance. Regular checks can help ensure continued reliable operation.

8. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
No power to any output, power LED off.Enweghị ike ntinye, vol ntinye na-ezighi ezitage, main fuse blown.Check input power source. Verify input voltage. Replace main fuse if blown (ensure correct rating).
No power to a specific output, other outputs working.Blown fuse for that specific output, faulty wiring to the device.Identify and replace the blown output fuse. Check wiring to the affected device.
Fuses blow frequently.Overcurrent draw from connected device, short circuit in wiring or device.Reduce load on the output. Inspect wiring and connected device for short circuits. Ensure correct fuse rating.
Module feels excessively hot.Overload, insufficient ventilation, loose connections.Reduce total load. Ensure adequate airflow. Tighten all terminal connections.

9. Akwụkwọ ikike na nkwado

For warranty information and technical support, please refer to the official Altronix website or contact Altronix customer service directly. Keep your purchase receipt for warranty claims.

Altronix Corporation
Websaịtị: www.altronix.com
Contact information can typically be found on their websaịtị.

Akwụkwọ ndị emetụtara - PD4

Tupuview Altronix ALTV1224DC Usoro CCTV Ntuzi nwụnye ọkụ na-eweta
Comprehensive installation guide for Altronix ALTV1224DC Series CCTV Power Supplies. Details models, specifications, features, terminal identification, safety warnings, and enclosure dimensions for reliable CCTV power distribution.
Tupuview Altronix PD8/PD8CB Power Distribution Modules - Specifications and Installation Guide
Comprehensive guide for Altronix PD8 and PD8CB power distribution modules, detailing their overview, technical specifications, and step-by-step installation instructions for 8 fused or PTC protected outputs.
Tupuview Ntuziaka ntinye nke Altronix ACMS12 Series Access Power Controllers
Ntuziaka ntinye maka ndị njikwa ike ohere nke Altronix ACMS12 na ACMS12CB usoro. Nkọwapụta nkọwapụta, waya, na eserese ngwa maka sistemụ njikwa ohere nchekwa.
Tupuview Altronix ALTV2432 Series 32-Output CCTV Power Supply Installation Guide
Installation guide for the Altronix ALTV2432 Series 32-output CCTV power supplies, detailing models, specifications, and installation instructions for 24VAC and 28VAC operation.
Tupuview Altronix ALTV2416 Usoro 16-Mpụta CCTV Ntuziaka ntinye ọkụ
Installation guide for Altronix ALTV2416 Series 16-Output CCTV Power Supplies, detailing models, specifications, features, installation instructions, terminal identification, and enclosure dimensions.
Tupuview Altronix ALTV244UL Series CCTV Ntuzi Nrụnye Ike
Installation guide for Altronix ALTV244UL series CCTV power supplies, detailing models, specifications, installation instructions, and enclosure dimensions. Features 24VAC/28VAC outputs with fuse or PTC protection for CCTV cameras and video accessories.